The following features are supported but not available for order on Note: Four BPDs are required for p5-590 servers equipped with one The redundant Integrated Battery Backup (#6201) is used to back up
the indicated model for MT 9119.
Supported Features on 7040-61D (#4643)
FC DESCRIPTION MIN MAX/Dwr MAX/Sys Note
2737 Keyboard/Mouse Attachment Card 0 2 4
2848 POWER GXT135P Graphics Accelerator 0 2 4
2946 Turboways 622 Mbps PCI MMF ATM 0 10 20 AIX
Adapter Only
3157 18.2 GB 10,000 RPM Ultra3 SCSI 0 16 112
Disk Drive Assembly
3158 36.4 GB 10,000 RPM Ultra3 SCSI 0 16 112
Disk Drive Assembly
3159 73.4 GB 10,000 RPM Ultra3 SCSI 0 16 112
Disk Drive Assembly
3273 36.4 GB 10,000 RPM Ultra320 SCSI 0 16 112
Disk Drive Assembly
3274 73.4 GB 10,000 RPM Ultra320 SCSI 0 16 112
Disk Drive Assembly
3275 146.8 GB 10,000 RPM Ultra320 SCSI 0 16 112
Disk Drive Assembly
3627 IBM P76/P77 Color Monitor, 0 4 4
Business Black, Captured Cable
3628 IBM P260/P275 Color Monitor, 0 4 4
Business Black, and Cable
3635 T210 Flat-Panel Monitor 0 4 4
4953 IBM 64bit/66MHz PCI ATM 155 UTP 0 20 20 AIX
Adapter Only
4957 IBM 64bit/66MHz PCI ATM 155 MMF 0 20 20 AIX
Adapter Only
4960 IBM e-business Cryptographic 0 4 8
Accelerator
4961 IBM Universal 4-Port 10/100 Ethernet 0 20 20
Adapter
4963 PCI Cryptographic Coprocessor 0 4 8
(FIPS-4)
6203 PCI Dual Channel Ultra3 SCSI Adapter 0 10 10
6228 2 Gigabit Fibre Channel Adapter 0 20 20
for 64-bit PCI Bus
6230 Advanced SerialRAID Plus Adapter 0 12 12 AIX
Only
6231 128 MByte DRAM Option Card 0 12 12 AIX
Only
6235 32 MByte Fast-Write Cache Option Card 0 12 12 AIX
Only
6239 2 Gigabit Fibre Channel PCI-X Adapter 0 20 20
166,1171c1263,1273
Distribution (BPD) Assemblies (#7837) varies, depending on the number of
processor books and I/O drawers installed in the p5-590 server. The
following table provides the number of BPRs and BPDs required for each
combination:
1 Processor Book 2 Processor Books
Distribution (BPD) Assemblies (#7837) varies, depending on the
number of processor books, I/O drawers, and battery backup or
media drawer features installed. The following table provides
the number of BPRs and BPDs required for each combination and
unless noted by (#1) or (#2), assumes no IBB (#6200) nor Media
Drawer - rack mounted (#5795):
1 Processor 2 Processor
Book Books
----------- -----------
173c1275
---------------- -----------------
---- ---- ---- ----
177c1279
4 Drawers 4 2 (#1) 6 4
4 Drawers 4 2(1) 6 4
179,1180c1281,1282
6 Drawers 4 4 6 4
7 Drawers NA NA 6 6
6 Drawers 4 4 6 4 (1)
7 Drawers NA NA 6 4 (1,2)
181a1284,1288
Note: (1) When Integrated Battery Backup (#6200) is used, the above
noted BPDs are increased by 2.
(2) When the Media Drawer - rack mounted (#5795) is used, the
above noted BPDs are increased by 2.
183,1184d1289
processor book, four I/O drawers, and a battery backup (#6200).
191,1206c1296,1320
front-mounted power subsystem. It interfaces to the power
regulators with the feature number 6240 cable. If battery backup is
desired, one battery backup (#6200) should be ordered for each
power regulator in the front power subsystem. Refer to the "p590
system configurations" for diagrams showing positioning of the
battery backup units within the various combinations of system and
expansion racks available.
subsystem if redundancy is desired. It interfaces to the power
regulators via the feature number 6240 cable. If redundant battery
backup is desired, one feature number 6201 should be ordered for
each power regulator in the rear power subsystem. Refer to the
"p590 system configurations" for diagrams showing positioning of
the battery backup units within the various combinations of system
and expansion racks available.
the front-mounted power subsystem. It interfaces to the power
regulators (BPRs) with the feature number 6240 cable. If battery
backup is desired, one feature number 6200 is required to be
ordered for each BPR in the front power subsystem. The primary
battery backup features mount in the front of the CEC Rack. The
first and second battery backup units are mounted in the 13U and
15U locations within the CEC Rack. If a third primary backup
feature is required, it will be mounted at the 11U location.
Refer to the "p5 590 system configurations" for diagrams showing
positioning of the battery backup units within the various
combinations of system CEC Rack.
the rear-mounted power subsystem if redundancy is required. It
interfaces to the power regulators (BPRs) with the feature number
6240 cable. If redundant battery backup is desired, one feature
number 6201 is required to be ordered for each BPR in the rear
power subsystem. The redundant battery backup features mount in
the rear of the CEC Rack behind the primary battery backup
features. The first and second battery backup units are mounted in
the 13U and 15U locations within the CEC Rack. If a third
redundant backup feature is required, it will be mounted at the
11U location. Refer to the "p5 590 system configurations" for
diagrams showing positioning of the battery backup units within
the CEC Rack.
269,1271d1382
supported in 7040-61D I/O drawers, if attached. Unsupported adapters
must be removed before attaching the drawer to the p5-590 server.
290c1401
p590 System Configurations
p5 p590 System Configurations
338c1449
p590 System Configurations
p5 p590 System Configurations
797d1907
798a1909,1910
856a1969
857a1971
860,1864c1974
866a1977
867a1979,1980
868a1982,1983
869a1985
873a1990,1992
875d1993
877a1996,2003