  • Temperature: 10 to 32(1) degrees C (50 to 90* degrees F) for 16-to
    32-way

    Note: (1) The above maximum temperature of 32 degrees C (90 degrees F) is
    linearly derated above 1,295 m (4,250 ft) as follows:


    • The maximum altitude for 16-way and 32-way p5-590 systems is 3,048 m
      (10,000 ft).
    • The maximum temperature at 3,048 m (10,000 ft) is 24 degrees C (46.4
      degrees F).

    • Temperature:

      • 10 to 32(1) degrees C (50 to 90(1) degrees F) for 16- to 32 way

      • 10 to 28(1) degrees C (50 to 82(1) degrees F) for all configurations
        with rack mounted Media Drawer (#5795)

      Note: (1) The above maximum temperatures of 32 degrees C (90 degrees F),
      28 degrees C (82 degrees F) are linearly derated above 1,295 m
      (4,250 ft) as follows:


      • The maximum altitude for 16- to 32-way systems w/o #5795 is
        3,048 m (10,000 ft). The maximum temperature at 3,048 m (10,000
        ft) is 24 degrees C (75 degrees F).

      • The maximum altitude for 16- to 32-way systems with #5795 is
        2,591 m (8,500 ft). The maximum temperature at 2,591 m (8,500
        ft) is 24 degrees C (75 degrees F).

        420,1424c1427,1441

      • The recommended devices for reading CD media are the 7212-102,
        7210-025, or 7210-030. These devices attach via a PCI SCSI adapter in
        one of the system I/O drawers.

      • If a NIM server is used, it must attach via a PCI LAN adapter in one
        of the system I/O drawers. An Ethernet adapter is recommended.

      • The recommended devices for reading CD media are the rack mounted
        media drawer #5795, 7212-102, 7210-025, or 7210-030. The Media
        Drawer #5795 is mounted in the 13U location of the CEC Rack;
        whereas, the 7212-102, 7210-025, and 7210-030 devices attach via
        a PCI SCSI adapter in one of the system I/O drawers.

      • Rack mounted Media Drawer (#5795) provides a 1U high internal
        media drawer for use with the p5 590 (9119-590). This media
        drawer will be located in the 13U position of the CEC Rack. The
        media drawer displaces any I/O drawer or battery backup feature
        components which would be located in the 13U through 16U location
        of the primary system rack. The Media Drawer (#5795) provides a
        fixed configuration which must be ordered with three media
        devices and all required SCSI and power attachment cabling.

      • If a NIM server is used, it must attach through a PCI LAN adapter in
        one of the system I/O drawers. An Ethernet connection is recommended.

        181d2197

        Note: Two SCSI cables are required when ordered with Media Drawer #5795


        708,3713c3724,3729
        devices. The media drawer is divided into front and rear sections. Each
        section of the media drawer is powered separately from the first system
        I/O drawer, either a 5791 or 5794, and must be cabled to separate ports
        of two SCSI PCI adapters. The front section contains two media bays and
        the rear section contains one media bay. The device in the rear is only
        accessible from the rear of the system.
        devices. The media drawer is divided into front and rear sections.
        Each section of the media drawer is powered separately from the
        first system I/O drawer, either a 5791 or 5794, and must be cabled
        to two SCSI PCI adapters. The front section contains two media bays
        and the rear section contains one media bay. The device in the
        rear is only accessible from the rear of the system.

        014a4031

        (No Longer Available as of June 24, 2005)


        381a4399

        (No Longer Available as of June 24, 2005)