c4

Revised:  March 23, 2005.



Revised:  April 19, 2005.



52a353
9419-HB7 |X| IBM ThinkVision L191p 19-inch LCD Flat-panel Monitor

79a481
0453 |A| Customer Specified Placement

28a531
3578 |A| 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly

82c585
5709 |A| Dual Channel SCSI RAID Enablement Card
5709 |S| Dual Channel SCSI RAID Enablement Card

87a591
5726 |A| Dual Channel SCSI RAID Enablement Card

34a639,643
6598 |A| Disk Slot Fillers (Quantity 4)
6651 |A| Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A), Plug
| | Type #75
6659 |A| Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A), Plug
| | Type #76

45c654
7165 |A| OEM Rack-mount Drawer Rail Kit
7165 |S| OEM Rack-mount Drawer Rail Kit

75a685
7894 |A| 8192MB (4x2048MB) DIMMs, 276-pin, 533MHz DDR2 SDRAM

61,862c871

  • One service processor (a second service processor is optional for
    multi-drawer configurations)

  • One service processor

    579a1589,1592

  • SPECIFY CODES

    • (#0453) - Customer Specified Placement


    585a1599
  • (#5726) - Dual Channel SCSI RAID Enablement Card

    683a1698,1699
  • (#3578) - 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
  • (#6598) - Disk Slot Fillers (Quantity 4)

    757a1774
  • (#7894) - 8192MB (4x2048MB) DIMMs, 276-pin, 533MHz DDR2 SDRAM

    812a1830,1833
  • (#6651) - Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A),
    Plug Type #75
  • (#6659) - Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A),
    Plug Type #76

    938a1960,1985

    (#0453) - Customer Specified Placement


    This feature allows specifying placement of I/O components
    based on customer specific requirments. The component placement
    will be configured by IBM manufacturing prior to shipment.
    Feature 0453 requests that IBM deliver the system to the
    customer according to the slot in drawer hardware placement
    defined within the LPAR Verification Tool (LVT). It eliminates
    the need to have these parts relocated at the customer location,
    as may happen if the order is placed without this feature
    code. It requires the account team to submit the LVT output to
    IBM manufacturing via a web site. It also requires the account
    team to assure that the LVT information submitted reflects the
    actual order placed.


    • Attributes provided: I/O component placement
    • Attributes required: LVT tool input
    • For 9117-570: (#0453)

      • Minimum required: 0
      • Maximum allowed: 1 (Initial order maximum: 1 )
      • OS level required: None
      • Initial Order/MES/Both/Supported: Initial
      • CSU: Does not apply
      • Return parts MES: Does not apply



    128a3176,3214

    (#3578) - 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly


    The 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 300
    GB of storage capacity and supports the industry standard Ultra320 SCSI
    interface speed of up to 320 MBps.

    Characteristics:


    • Form Factor: 3.5-inch, 1-inch (25 mm) high
    • Cable included: No
    • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
    • Attachment Industry Spec: SCSI U320
    • Average Seek Time: 4.9 ms (based on four(4) READS to one(1) WRITE)
    • Average Latency: 2.99 ms
    • Rotational Speed: 10,000 RPM
    • Maximum Data Transfer Rate: 88 MBps

    Limitation: This disk drive requires attachment to a supported
    Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI
    cable/backplane in order for the drive to run at 320 MBps. Also, any and
    all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3,
    or Ultra320 SCSI device(s) in order for this disk drive to run at 320
    MBps.


    • Attributes provided: 300 GB of disk storage mounted in a carrier.
    • Attributes required: One disk drive bay.
    • For 9117-570: (#3578)

      • Minimum required: 0
      • Maximum allowed: 24 (Initial order maximum: 24 )
      • OS level required: AIX V4.3 or higher PSSP levels 3.1, 3.2 and higher
        Linux- Refer to the following Web Site for Linux information:
        http://www.ibm.com/servers/eservers/pseries/hardware/
        factsfeatures.html
         


      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No



    489a4576

    (No Longer Available as of May 12, 2005)


    744a4832,4889

    (#5726) - Dual Channel SCSI RAID Enablement Card


    The Dual Channel SCSI RAID Enablement Card (#5726) is a bootable
    high performance SCSI RAID Enablement feature providing RAID 0,5,
    or 10 capability to select pSeries systems with the appropriate
    supporting integrated SCSI adapter and internal multiple disk
    drives or packs of drives.
    To increase the data writing performance, a 16 MByte non-volitile
    fast-write cache is provided as a resident part of this feature.
    The 16 MByte fast-write cache can provide an improvement in data
    throughput and response time during certain sequence write
    operations compared to SCSI RAID adapters without the fast-write
    cache. The response time and data transfer improvement will
    vary depending upon the data block sizes, the percentage of
    sequential writes, machine type/model, and application parameters.
    When an array configuration is selected with the RAID Manager, the
    disk drives being designated as part of the array are required to
    be formatted to 522 byte sectors. 522 byte sectors provide
    additional CRC error checking for improved data integrety. A
    menu option is provided in the AIX supporting software which
    will reformat these disk drives prior to their usage in an
    array. Conversely, when a disk drive is removed from an array,
    a similar menu option is also provided to re-format them back to
    512 byte sectors. Note: Some disk drives require that their
    microcode be updated to the latest level before being formatted to
    522 Byte Sectors. Also, there are some disk drives which do not
    support being formatted to 522 Byte Sectors. The PCI-X SCSI Disk
    Array Manager will inform the user of these known situations when
    they exist. For disk microcode updates, go to the following web
    page URL:


    http://techsupport.services.ibm.com/server/mdownload/


    Limitation: Even though the supporting integrated adapter with the
    Dual Channel SCSI RAID Enablement Card has ports that run at ultra320
    SCSI speeds (up to 320 MBytes/s), the internally attached disk
    drives will run at a maximum SCSI bus data rate specified by
    that supporting system disk backplane.


    • Attributes provided: Internal disk drives to be configured as
      an array.
    • Attributes required: System with supporting integrated SCSI adapter.
    • For 9117-570: (#5726)

      • Minimum required: 0
      • Maximum allowed: 4 (Initial order maximum: 4 )
      • OS level required: AIX 5.2 or AIX 5.3, or later; Linux - Refer
        to the following URL for systems and features that operate with Linux:
        http://www.ibm.com/servers/eserver/pseries/
        hardware/factsfeatures.html
         


      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No

      Note: Each system drawer can have a maximum of one feature #5709 or
      #5726.



    193c5338
  • Initial Order/MES/Both/Supported: Supported
  • Initial Order/MES/Both/Supported: MES

    602a5748,5803

    (#6598) - Disk Slot Fillers (Quantity 4)


    This feature allows the customer to move disks from the system to
    another system or an IO drawer and to place a blank disk filler in the
    empty disk slot. Systems shipped from manufacturing have blank filler
    in the empty disk slots.


    • Attributes provided: 4 disk slot fillers
    • Attributes required: None
    • For 9117-570: (#6598)

      • Minimum required: 0
      • Maximum allowed: 2 (Initial order maximum: 2 )
      • OS level required: None
      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No


    (#6651) Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A), Plug Type #75


    This power cord goes from the system and/or peripheral features to
    a wall-type outlet. Plug type #75 (KETI). Refer to Corporate
    Bulletin C-B-2-4700-009 for a description of plug types.
    The following countries/regions use the #6651 power cord to power
    the system and/or peripheral features requiring a power cord: Taiwan


    • Attributes provided: Power cord
    • Attributes required: None
    • For 9117-570: (#6651)

      • Minimum required: 0
      • Maximum allowed: No max (Initial order maximum: No max )
      • OS level required: None
      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No


    (#6659) Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A), Plug Type #76


    This power cord goes from the system and/or peripheral features to
    a wall-type outlet. Plug type #76 (KETI). Refer to Corporate
    Bulletin C-B-2-4700-009 for a description of plug types.
    The following countries/regions use the #6659 power cord to power
    the system and/or peripheral features requiring a power cord: Taiwan


    • Attributes provided: Power cord
    • Attributes required: None
    • For 9117-570: (#6659)

      • Minimum required: 0
      • Maximum allowed: No max (Initial order maximum: No max )
      • OS level required: None
      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No



    701c5902,5903
    system in an IBM 19-inch rack.
    system in an IBM 19-inch rack. Because the rail depth is adjustable,
    this feature can also be installed in OEM racks from non-IBM vendors.

    717a5920

    (No Longer Available as of May 12, 2005)


    199a6403,6422

    (#7894) - 8192MB (4x2048MB) DIMMs, 276-pin, 533MHz DDR2 SDRAM


    Provides 8192MB of DDR2 system memory with 4 2048MB DIMMs.


    • Attributes provided: 8192MB of system memory
    • Attributes required: Four empty memory DIMM positions
    • For 9117-570: (#7894)

      • Minimum required: 0
      • Maximum allowed: 16 (Initial order maximum: 16 )
      • OS level required: AIX 5.2 or AIX 5.3, or later; Linux - Refer
        to the following URL for systems and features that operate with Linux:
        http://www.ibm.com/servers/eserver/pseries/hardware/
        factsfeatures.html
         


      • Initial Order/MES/Both/Supported: Both
      • CSU: Yes
      • Return parts MES: No



    014a8238,8253







     
    Terms of use


    [
    Help
    ]




    026,8027d8264
      |  
    Terms of use

    030c8267
    Contact
    Contact