94a517,532
The following table shows the tape drive attachment options of each
3592 Model J70 Controller in all configurations:
3592 Model J70 3590 Model E1x
Controller or H1x (FCP) 3592 Model J1A
------------------------- --------------- --------------
3494 D14 and adjacent L12 6
3494 D14 and adjacent D12 10
3590 A14 and 2 multi A14 12
3590 C10 and 3 C12 12
Rack 12
3494 D24 and adjacent L22 12
3494 D24 and adjacent D22 16
3590 C10 and 3592 C20 16
Rack 16
97,504c535,822
to a 3592 Model J70 Controller requires an IBM 2109 SAN Fibre Channel
Switch, which must be separately ordered and is installed in the rack or
frame containing the 3592 Model J70 Controller. A 2109 Model F16 or S16
Switch can be used, although the Model S16 Switch is no longer marketed
by IBM as of September 13, 2002. The 2109 Model F16 Switch is required
to support a 2-Gbps link speed to the 3592 Model J70 Controller. The
2109 Model F16 or S16 Switch must have the appropriate number of Gigabit
Interface Convertor (GBIC) features.
to a 3592 Model J70 Controller requires a 2Gb Fibre Channel Switch
feature (#3487 or #4887) or an IBM 2109 SAN Fibre Channel Switch, which
must be separately ordered and is installed in the rack or frame
containing the 3592 Model J70 Controller. A 2109 Model F16 or S16 Switch
can be used, although they are no longer available through IBM. The 2Gb
Fibre Channel Switch or the 2109 Model F16 Switch is required to support
a 2-Gbps link speed to the 3592 Model J70 Controller. The 2109 Model
F16 or S16 Switch must have the appropriate number of Gigabit Interface
Convertor (GBIC) features.
The following features are required for attaching a tape drive
to a 3592 Model J70 Controller in the various environments:
Fibre Channel Tape Drive Attachment to 2Gb Fibre Channel Switch
or External Fabric
The 3592 Tape Drives or 3590 Fibre Channel Tape Drives can be attached
to a 3592 Model J70 Controller with an 2Gb Fibre Channel Switch, which
must be separately ordered as a feature and is installed in the rack or
frame containing the 3592 Model J70 Controller.
The following features are required for attaching a tape
drive through the 2Gb Fibre Channel Switch or External Fabric to a 3592
Model J70 Controller in the various environments:
- 3592 Model J70 Controller Requirements:
- Feature #9476 (J1A Drive Attached to controller must be specified on
the 3592 Model J70 if attaching 3592 drives.
- Feature #3476 (Two LC Fibre Channel Drive Adapters) and feature #3487
(2Gb Fibre Channel Switch) or feature #4887 (Reinstall 2Gb Fibre Channel
Switch) are required on the Model J70 when attaching 3592 or 3590 Tape
Drives with the 2Gb Fibre Channel Switch. A second 2Gb Fibre Channel
Switch (#3487 or #4887) can be installed to help provide redundancy.
- Feature #3476 (Two LC Fibre Channel Drive Adapters)
and feature #3491 or #9491 (External Fabric Support
Field or Plant) are required on the Model J70 when
attaching 3592 Tape Drives with a customer-supplied
external fabric or directly connecting drives to the controller.
- The 3592 Tape Drives, and different models of the
3590 Tape Drive, cannot be intermixed
on the same switch when attaching to the Model J70.
- Rack Requirements:
- 3592 Model J70 Controller:
- Feature #4641 (Install Controller in a rack must be specified).
- Feature #3485 (2Gb Fibre Channel Drive Attach Rack) provides hardware
for installing the 2Gb Fibre Channel Switch in the rack and
cables from the Model J70 to the switch.
- Feature #3489 (Redundant 2Gb Attach Rack) provides hardware
for installing a second 2Gb Fibre Channel Switch in the rack.
- One feature #3059 (3592 Drive-to-Switch Cables) must be specified on
the Model J70 for each 3592 Tape Drive attached to the Model J70 in the
rack that contains the Model J70. If feature #3491 or #9491 is specified
and one or two 3592 Model J1A Tape Drives are directly attached to the
Model J70, one or two of feature #3059 must be specified.
- One feature #9059 (3590 Tape Drive Attached) must be specified on the
Model J70 for each 3590 Tape Drive attached to the Model J70 in the rack
that contains the Model J70.
- 3592 Tape Drives in a stand-alone rack:
- Feature #6013, #6025, or #6061 (LC/LC Fibre Channel Cables) must be
specified on each tape drive not in the rack with the Model J70 to
provide one short-wavelength cable to attach those tape drives
to the 2Gb Fibre Channel Switch or to the customer-supplied fabric.
- Up to twelve 3592 Model J1A Tape Drives will fit
with a Model J70 in a 2-m rack.
- Up to eight 3592 Model J1A Tape Drives will fit
with a Model J70 in a 1.8-m or 1.6-m rack.
- Up to 16 3592 Tape Drives can be attached to a single Model J70 when
using the 2Gb Fibre Channel Drive Attach Rack feature (#3485)
- 3590 Tape Drives in a stand-alone rack:
- Feature #3510 or #9510 (Fibre Channel Attachment)
must be specified on each 3590 Tape Drive.
- Feature #5913, #5922, or #5961 (LC/SC Fibre Channel Cables) must be
specified on each 3590 Tape Drive not in the rack with the Model J70 to
provide one short-wavelength cable to attach those tape drives to the 2Gb
Fibre Channel Switch.
- Up to four 3590 Tape Drives will fit with a Model J70 in a 2-m or
1.8-m rack.
- Up to two 3590 Tape Drives will fit with a Model J70 in a 1.6-m
rack.
- Up to twelve 3590 Tape Drives (in up to three
racks) can be attached to a single Model J70
when using the 2Gb Fibre Channel Drive Attach Rack - feature (#3485)
- Silo Requirements:
- 3590 Model C10 Silo Compatible Frame:
- One feature #3514 (2Gb Fibre Channel Drive Attach) must be specified
for each 3592 Model J70 installed in a Model C10 Frame that will have
3590 Fibre Channel attached tape drives or a 3592 Tape Drive attaching to
the Model J70 through a 2Gb Fibre Channel Switch (#3487 or #4887).
- One feature #3515 (Redundant 2Gb Attach)
must be specified to install a second 2Gb Fibre Channel Switch
(#3487 or #4887) to help provide redundancy.
- Feature #3491 or #9491 (External Fabric Support Field or
Plant) are required on the Model C10 Frame in place of feature #3514
when attaching 3592 Tape Drives with a customer-supplied external fabric.
- 3592 Model C20 Silo Compatible Frame:
- One feature #4831 or #9675 (Install the 3592 Model J1A in a Model C20
Frame) must be specified on a 3592 Model C20 frame for each attached 3592
Tape Drive.
- 3592 Tape Drive:
- A single 3592 Model J70 can attach up to 16 3592 Tape Drives in a
3590 Model C20 Frame for use with a StorageTek 9310 PowderHorn tape
library when using the 2Gb Fibre Channel Switch feature (#3514).
- One appropriate length short-wavelength Fibre Channel cable, feature
#6013, #6025, or #6061 (LC/LC Fibre Channel Cables), must be specified
on each 3592 Tape Drive to attach to the 2Gb Fibre Channel Switch feature
(#3514) or two if the Redundant 2Gb Attach (#3515) is ordered. These
cable features can also be used to attach to a customer-supplied fabric
or to directly attach up to two 3592 Tape Drives to a Model J70.
- 3590 Model C12 Silo Compatible Frame:
- One feature #3511 (Install Fibre Channel Drive) must be specified on
a 3590 Model C12 Frame for each attached 3590 Tape Drive.
- 3590 Tape Drive:
- A single Model J70 can attach to up to twelve 3590 Tape Drives in up
to three 3590 Model C12 Frames for use with a StorageTek 9310 or 4410
tape library when using the 2Gb Fibre
Channel Switch feature (#3514).
- Feature #3510 or #9510 (Fibre Channel Attachment)
must be installed on each 3590 Tape Drive.
- One appropriate length short-wavelength Fibre Channel cable, feature
#5913, #5922, or #5961 (LC/SC Fibre Channel Cables), must be specified
on each 3590 Tape Drive to attach to the 2Gb Fibre Channel Switch feature
(#3514) or two if Redundant 2Gb Attach (#3515) is ordered.
- 3590 Model A14 Frame Requirements (3590 Tape Drives only):
- Feature #3486 (2Gb Fibre Channel Drive Attach) must be specified on
the frame that contains the Model J70 Controller with the 2Gb Fibre
Channel Switch (#3487 or #4887).
- One feature #3490 (Redundant 2Gb Attach)
must be specified to install a second 2Gb Fibre Channel Switch
(#3487 or #4887) to help provide redundancy.
- Feature #4084 (Multiframe 2Gb 3590) must be specified on the other
Model A14 Frames that contain Fibre Channel tape drives that will be
attached to the Model J70 Controller with
the 2Gb Fibre Channel Switch (#3487 or #4887) depending on the
number of #3487 or #4887 installed on the 3592 Model J70.
- Feature #9670 (Plant Install Hxx Fibre Drive),
or #9672 (Field Merge Hxx Drive), or #4672 (Field Install Hxx Drive) must
be specified on the Model A14 - one feature for each
3590 Model H11 Tape Drive with feature #9510 (Fibre
Channel Attachment) installed in that Model A14 coming from the plant.
- Feature #9511 (Plant Install Fibre Drive) must be specified on the
Model A14, instead of feature #9663 (Plant Install Drive) - one feature
for each 3590 Model E11 Tape Drive with feature
#9510 (Fibre Channel Attachment) installed in that
Model A14 coming from the plant.
- One feature #9059 (3590 Tape Drive Attached) must be
specified on the Model J70 for each tape drive
attached to the Model J70 in the Model A14 Frame that
contains the Model J70.
- The maximum distance between Model A14 Frames is seven meters.
- Enterprise Tape Library 3494 Requirements:
- 3592 Tape Drive Attachment:
- Feature #3486 (2Gb Fibre Channel Drive Attach) must be specified on
the 3494 Model D24 or D14 Frame that contains the Model J70 Controller
with the 2Gb Fibre Channel Switch (#3487 or #4887).
- One feature #3490 (Redundant 2Gb Attach)
must be specified on the 3494 Model D24 or D14 Frame
to install a second 2Gb Fibre Channel Switch
(#3487 or #4887) to help provide redundancy.
- Feature #3491 or #9491 (External Fabric Support Field or Plant) is
required on the 3494 Model D24 Frame in place of feature #3486
when attaching 3592 Tape Drives with a customer-supplied
external fabric or direct connection between the controller and
up to two drives.
- Feature #4085 (Adjacent Frame 2Gb 3592) must be specified on the
associated 3494 Model L22 or D22 Frame that contains the other 3592
Tape Drives that will be attached to the Model J70 Controller
with the 2Gb Fibre Channel Switch (#3487 or #4887).
Up to 4 3592 Tape Drives can be installed in an adjacent
Model L22 or 8 in a Model D22 Frame, for a total of up to 16 3592
Tape Drives attached to a 3592 Model J70 Controller depending on the
number of #3487 or #4887 installed on the 3592 Model J70.
- Feature #3491 or #9491 (External Fabric Support Field or Plant) are
required on the Model L22 or D22 Frame in place of feature #4085 when
attaching 3592 Tape Drives with a customer-supplied external fabric.
- One feature #3059 (3592 Drive-to-Switch Cables) must be specified on
the Model J70 for each 3592 Tape Drive attached to the Model J70 with the
2Gb Fibre Channel Switch in the Model D24 Frame. Up to eight 3592 Tape
Drives can be attached to a 3592 Model J70 Controller and installed
together in a Model D24 Frame.
If feature #3491 or #9491 is specified and one or two 3592 Model J1A
Tape Drives are directly attached to the Model J70, one or two of feature
#3059 must be specified.
- 3590 Tape Drive Attachment:
- Feature #4084 (Adjacent Frame 2Gb 3590) must be specified on the
associated 3494 Model L12 or D12 Frame that contains the other
3590 Tape Drives that will be attached to the Model
J70 Controller with the 2Gb Fibre Channel Switch (#3487 or #4887).
Up to two 3590 Tape Drives can be installed in an adjacent Model L12
Frame or six 3590 Tape Drives in a D12 Frame, for a
total of up to 10 3590 Tape Drives attached to a 3592
Model J70 Controller when using the 2Gb Fibre Channel
Drive Attach (#3486) depending on the number of #3487 or #4887
installed on the 3592 Model J70.
- Feature #9670 (Factory Install H1A Fibre Drive), or #9671 (Field
Merge H1A Drive), or #4671 (Field Install H1A Drive) must
be specified on the Model D14 - one feature for each
3590 Model H1A Tape Drive with feature #9510 (Fibre
Channel Attachment) installed in that Model D14
coming from the plant.
- Feature #9511 (Factory Install Fibre Drive) must be
specified on the Model D14, instead of feature #9663
(Factory Install E1A) - one feature for each 3590
Model E1A Tape Drive with feature #9510 (Fibre Channel
Attachment) installed in that Model D14 coming from the plant.
- One feature #9059 (3590 Tape Drive Attached) must be
specified on the Model J70 for each 3590 Tape Drive
attached to the Model J70 with the 2Gb Fibre Channel Switch
in the Model D14 Frame. Up to four 3590 Tape Drives can be attached to a
3592 Model J70 Controller and installed together in a Model D14 Frame.
- One feature #3511 (Install Fibre Channel Drive) must be
specified on a 3494 Model D12 or L12 Frame for each installed tape drive.
Fibre Channel Drive Cables
For attachment to the 2Gb Fibre Channel Switch, the following cables
should be specified:
- 3494 Installation: Fibre Channel cables for attachment of 3592 or
3590 Tape Drives in a 3494 Tape Library to a 3592 Model J70 Controller
via the 2Gb Fibre Channel Switch are included when feature #3486, #3490,
#4084, or #4085 is specified on those frames. The
number of cables in the frame containing the Model J70 are specified by
the quantity of feature #3059 or #9059 on the Model J70.
- 3590 Model A14 Installation: Fibre Channel cables for attachment of
3590 Tape Drives in a 3590 Model A14 Frame to a 3592 Model J70 Controller
are included when feature #3486, #3490, or #4084 is specified on those
frames. The number of cables in the frame containing the Model J70 is
specified by the quantity of feature #9059 on the Model J70.
- Silo Installation: The appropriate length
Fibre Channel cables for attachment of 3592 Tape Drives in a 3590 Model
C20 Frame to a 3592 Model J70 Controller in a C10 Frame can be ordered
with each 3592 Tape Drive using feature #6013, #6025, and #6061 (LC/LC
Fibre Channel Cables) when feature #3487 or #4887
is ordered on the Model J70. The appropriate length
Fibre Channel cables for attachment of 3590 Tape Drives in a 3590 Model
C12 Frame to a 3592 Model J70 Controller in a C10 Frame can be ordered
with each 3590 Tape Drive using features #5913, #5922, and #5961 (LC/SC
Fibre Channel Cables) when feature #3487 or #4887
is ordered on the Model J70.
- Rack Installation: The appropriate length Fibre Channel cables
for attachment of 3592 Tape Drives in a rack to the 3592 Model J70
Controller in another rack must be ordered with each 3592 Tape Drive
using feature #6013, #6025, and #6061 (LC/LC Fibre Channel Cables)
when feature #3487 or #4887 is ordered on the Model J70. Cables
from 3592 Tape Drives to the Model J70 that are in the rack with the
Model J70 are specified by the quantity of feature #3059 on the Model
J70. The appropriate length Fibre Channel cables
for attachment of 3590 Tape Drives in a rack to the 3592 Model J70
Controller in another rack must be ordered with each 3590 Tape Drive
using feature #5913, #5922, and #5961 (LC/SC Fibre Channel Cables)
when feature #3487 or #4887 is ordered on the Model J70. Cables
from 3590 Tape Drives to the Model J70 that are in the rack with the
Model J70 are specified by the quantity of feature #9059 on the Model
J70.
For attachment to an External Fabric, the cables from the switch
to the 3592 Model J70 Controller should be ordered with the switch
or supplied separately. Cables from the tape drives to the switch
or directly to the Controller can be ordered with the tape drives or
controller as described above or supplied separately.
Refer to the IBM TotalStorage Enterprise Tape System 3592
Introduction and Planning Guide (GA32-0464)
for Fibre Channel cable planning information.
301,1302c1619,1621
alt="Back to top"/>Back to top
305c1624,1625
|
|
| |