This feature provides one UPS for one engine (node) of the SAN Volume For new SVC clusters ordered after May 10, 2005 which will run with Feature numbers 8115 and 8100 may be mixed in a SVC cluster only if Each UPS includes a power (line) cord for connecting the UPS to a rack This feature is plant installed only. Note: For new SVC clusters using SVC Storage Software V2, or later, the This feature is for administrative purposes only and specifies that This feature provides one UPS for one engine (node) of the SAN Volume For new SVC clusters ordered after May 10, 2005 which will run with Feature numbers 8115 and 8100 may be mixed in a SVC cluster only if Each UPS includes a power (line) cord for connecting the UPS to a rack This feature is plant installed only. Note: (1) For new SVC clusters using SVC Storage Software V2, or later,
Controller cluster. (Feature number 8100 provided a pair of UPSs, each
of which supported two engines.) UPS - single (#8115) requires SVC
Storage Software V2, or later.
SVC software V2, or later, feature number 8100 may not be ordered; one
UPS - single must be ordered for each engine of a SVC cluster, both for
the initial engine (#3001) and for additional engines (#3002).
SVC Storage Software V2, or later, is installed on the cluster.
PDU. Country-specific power cords, specified by feature number, must
also be ordered when each UPS is ordered.
minimum is one. For existing clusters using SVC Storage Software V1, and
upgrading with additional nodes, the minimum is none.
Storage Software V1.x.
125d1093
SVC Storage Engine 2145 4F2
128a1097
Site secondary HW cluster 2145 4F2 0019 Plant No
138a1108
UPS - Single 2145 4F2 8115 Plant No
191a1162,1181
(#0019) Site secondary HW cluster
the order for a new cluster is not for the first cluster to be installed
at the customer site; it specifies that this is for a subsequent cluster
to be installed at the same site. Specifying feature #0019 will verify
that no software is to be ordered, that is, that a software license is
already in effect for a SVC cluster installed at the customer site.
installed at site.
414a1405,1434
(#8115) UPS - Single
Controller cluster. (Feature number 8100 provided a pair of UPSs, each
of which supported two engines.) UPS - single (#8115) requires SVC
Storage Software V2, or later.
SVC software V2, or later, feature number 8100 may not be ordered; one
UPS - single must be ordered for each engine of a SVC cluster, both for
the initial engine (#3001) and for additional engines (#3002).
SVC Storage Software V2, or later, is installed on the cluster.
PDU. Country-specific power cords, specified by feature number, must
also be ordered when each UPS is ordered.
Storage Software V1.x.
the minimum is one. For existing clusters using SVC Storage Software V1,
and upgrading with additional nodes, the minimum is none.