The IBM TotalStorage SAN256N directors are capable as of November 19,
2004, when used in accordance with IBM's associated documentation, of
satisfying the applicable requirements of Section 508 of the
Rehabilitation Act, provided that any assistive technology used with the
product properly interoperates with it. A US Section 508 Voluntary
Product Accessibility Template (VPAT) can be requested via IBM's Web site
at:
- http://www-3.ibm.com/able/product_accessibility/index.html
21c256
50,251d284
Maximum
Not applicable.
83c516
SAN256N International Power Cord Bundle 9302 0 1
SAN256N North American Power Cord Bundle 9301 0 1
88,523c521,533
Latvia 9615 0 1
Morocco 9616 0 1
Tunisia 9617 0 1
Austria 9620 0 1
Belgium 9621 0 1
Denmark 9622 0 1
Finland, Norway 9623 0 1
France 9624 0 1
Germany 9625 0 1
Italy 9626 0 1
Liechtenstein 9627 0 1
Netherlands 9628 0 1
Portugal 9629 0 1
Russia 9630 0 1
Spain 9631 0 1
Sweden 9632 0 1
Switzerland 9633 0 1
Czech Republic 9635 0 1
Hungary 9636 0 1
South Africa 9637 0 1
Egypt 9638 0 1
Slovenia, Croatia 9639 0 1
Poland, Bulgaria 9640 0 1
Israel 9641 0 1
Greece 9642 0 1
Turkey 9643 0 1
Slovakia 9644 0 1
Saudi Arabia 9645 0 1
Romania 9646 0 1
Cyprus 9648 0 1
Gibraltar 9649 0 1
U.A.E 9681 0 1
Kuwait 9682 0 1
Oman 9683 0 1
Bahrain 9684 0 1
United Kingdom, Ireland, Hong Kong 9634 0 1
U.S. 9601 0 1
Canada 9602 0 1
Mexico 9603 0 1
Argentina 9604 0 1
Brazil 9605 0 1
Chile 9606 0 1
Columbia 9607 0 1
Bolivia 9608 0 1
Ecuador 9609 0 1
Paraguay 9610 0 1
Peru 9611 0 1
Uruguay 9612 0 1
Venezuela 9613 0 1
68,573c578,584
(#9601 - #9662) Country Kits
Summary: You must specify the specific Country Kit as a corequisite
of feature #7600, Enterprise Manager Server Bundle. Specify the
appropriate Country Kit based on the installation location. Features
#9601-#9662 will provide the appropriate power cords, monitor, modem, and
phone line adapter, and appropriate licenses.
(#9601 - 9686) Country Kits
Summary: You must specify the specific Country Kit as a
corequisite of feature #7600, Enterprise Manager Server Bundle.
Specify the appropriate Country Kit based on the installation location.
Features #9601-#9686 will provide the appropriate
power cords, monitor, modem, and phone line adapter, and appropriate
licenses.
75,576c586,587
Minimum Number of Features per 2045-N16: None.
Maximum Number of Features per 2045-N16: One.
Minimum Number of Features per 2042-N16: None.
Maximum Number of Features per 2042-N16: One.
72c683
9302 SAN256N International Power Cord Bundle
9301 SAN256N North American Power Cord Bundle
83a695,696
10 Gbps XFP Transceiver 2390 0 4
Switch Module 5301 0 1
84a698
10 Gbps ISL + 12 2 Gb FC IO Blade 5390 0 4
95a710,714
Fiber Trunking Break-out box 7645 0 1
Single mode 64-port cable bundle 7646 0 4
Multimode 64-port cable bundle 7647 0 4
Single mode 6-port cable bundle 7650 0 11
Multimode 6-port cable bundle 7651 0 11
98c717
SAN256N director features
SAN256N features
00,701c719,720
Summary: The SAN256N 16 Port Fibre Channel I/O Blade (#5316) can be
configured with either shortwave (#2214) or longwave (#2224) SFP
Summary: Fibre Channel ports on the SAN256N (2045-N16) director may
be configured with either shortwave (#2214) or longwave (#2224) SFP
05,717c724,731
configured on a SAN256N blade. All ports on the SAN256N blades must have
a transceiver ordered. Transceivers are ordered in increments of 16,
either shortwave, longwave, or a mix of shortwave and longwave based on
the number of I/O blades installed in the IBM TotalStorage SAN256N
director
The minimum required number of SFPs ordered with features #2214,
#2224, #2235, and #2280 is 32 to support the minimum requirement of two
SAN256N 16 Port Fibre Channel I/O Blades (#5316) per N16 Director. The
maximum number of SFPs (of all types) is 256.
- Co-req: Min = 2214 (4 pack) + 2224 (4 pack) + 2235 + 2280 = 32
- Co-req: Max = 2214 (4 pack) + 2224 (4 pack) + 2235 + 2280 = 256
configured for the 2 Gbps interfaces on the SAN n-type blades (#5316 and
#5390). The 10 Gbps interface on the 10 Gbps ISL I/O Blade (#5390)
requires a single form-factor pluggable transceiver, called an XFP,
designed for this link rate (#2390).
All available ports in the SAN256N director blades must have a
transceiver ordered. The total number of SFPs of all types required is
dependent upon the type and number of SAN256N blades ordered. Refer to
the SAN256N n-type Blades section for details.
19,728c733,742
Summary: This feature provides an additional four shortwave SFP
transceivers, designed to provide Fibre Channel connections at distances
up to 300 meters while using the appropriate 50.0/125 micrometer fiber
optic cable, and distances up to 175 meters while using the appropriate
62.5/125 micrometer fiber optic cable.
(#2224) LW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four longwave SFP
transceivers, designed to provide Fibre Channel connections at distances
up to 10 Km (6.2 miles), while using the appropriate 9.0/125 micrometer
single mode fiber optic cable.
Summary: This feature provides an additional four shortwave
SFP transceivers, designed to provide Fibre Channel connections
at distances up to 300 meters while using the appropriate 50.0/125
micrometer fiber optic cable, and distances up to 175 meters while
using the appropriate 62.5/125 micrometer fiber optic cable.
(#2224) LW SFP Transceiver - 4 Pack:
Summary: This feature provides an additional four longwave
SFP transceivers, designed to provide Fibre Channel connections
at distances up to 10 Km (6.2 miles), while using the
appropriate 9.0/125 micrometer single mode fiber optic cable.
34,735c748,750
Compatibility Conflicts: Combinations of all SFP Transceivers must
be ordered in increments of 16 transceivers.
Compatibility Conflicts: Combinations of all SFP Transceivers
must be ordered in increments equal to the number of available ports
on all SAN n-type blades ordered.
41,757c756,775
(#2235) Extended Distance 35 Km Longwave 2 GB SFP
Summary: The Extended Distance 35 Km Longwave 2 GB SFP option is
designed to provide extended distance up to 35 Km between supported
devices, while operating at 2 Gpbs. Dedicated port buffer credits within
the SAN256N director are designed to work with the 35 Km longwave 2 Gb
SFP to help users extend FCP and FICON Inter Switch Links (ISL)s up to 35
Km distance, in campus environments or metropolitan area networks. The
35 Km longwave 2 GB SFP is designed to be hot pluggable for use in any
port on the SAN256N 16 port blade (#5316).
(#2280) LW 80 Km 2 Gbps SFP Transceiver
Summary: The Extended Distance 80 Km Long Wave 2 Gigabit SFP option
is designed to provide (up to 80 km) Inter-Switch Links (ISLs) between
SAN256N directors while operating at 2 Gbps, depending upon optical cable
quality of the customer-provided dark fiber cable plant. The 80 Km Long
Wave 2 Gigabit SFP is designed to be hot pluggable for use in any port on
the SAN256N I/O blade (FC#5316). SAN256N 16 port I/O blades support both
shortwave and longwave SFP transceivers on the same module.
(#2235) Extended Distance 35 Km Longwave 2 Gbps SFP
Summary: The Extended Distance 35 Km Longwave 2 Gbps SFP option is
designed to provide extended, unrepeated distance up to 35 Km between
supported devices, while operating at 2 Gbps. Dedicated port
buffer credits within the SAN256N director are designed to
work with the 35 Km longwave 2 Gbps SFP to help users extend
FCP and FICON Inter-Switch Links (ISLs) up to 35 Km distance,
in campus environments or metropolitan area networks. The 35
Km longwave 2 Gbps SFP is designed to be hot pluggable for use
in any 1 or 2 Gbps port on the SAN256N n-type blades (#5316 and #5390).
(#2280) Extended Distance 80 Km Longwave 2 Gbps SFP
Summary: The Extended Distance 80 Km Long Wave 2 Gbps SFP option
is designed to provide (up to 80 km unrepeated) Inter-Switch Links (ISLs)
between SAN256N directors while operating at 2 Gbps, depending
upon optical cable quality of the customer-provided dark fiber
cable plant. The 80 Km Long Wave 2 Gbps SFP is designed to be
hot pluggable for use in any 1 or 2 Gbps port on the SAN256N I/O
blades (#5316 and #5390).
SAN256N I/O n-type blades support both shortwave and longwave SFP
transceivers on the same module.
63,764c781,783
Compatibility Conflicts: Combinations of all SFP Transceivers must