c5

Revised:  February 04, 2004.



Revised:  July 27, 2004.



9a30


34,835d834
Plant Install 2042-0001 in C40 Cabinet 9201
Cabinet Filler Panel 9202

37a837,839
Plant Install 2042-0001 in C40 Cabinet 9201
Cabinet Filler Panel 9202
Plant Install N16 into FC/9000 Model C40 Cabinet 9435

47,950c949,959

(#9201) Plant Install in 2042-C40 Cabinet


Specify this feature in your initial order to indicate the number of
2042-001 FC/9000 Directors that will be plant installed in a 2042-C40
Cabinet.

C40 Cabinet Installation Codes


The CNT FC/9000 40U Cabinet (C40) can contain one or two CNT FC/9000
Model 001 (2042-001), or CNT UltraNet Multi-service Directors (2042-N16).
Feature #9201, for Model 001, and #9235, for Model N16, will configure
the director into a new FC/9000 Model C40 Cabinet purchase.

For New C40 Order, must order #9201 = Min 1 Unit, or #9435 = Min 1
Unit (C40 must include at least one model 001 or one model N16).

(#9201) Plant Install Model 001 into CNT FC/9000 C40 Cabinet


Specify this feature in your initial order of the CNT FC/9000 Cabinet
to designate that the Model 001 FC/9000 Director will be plant installed
in a 2042-C40 Cabinet.


52c961
  • Minimum Number of Features per 2042-C40: One.
  • Minimum Number of Features per 2042-C40: None.

    55,957c964,969
  • Corequisites: Feature #9202 if only one 2042 Model 001 is to be
    installed ion the 2042-C40 Cabinet.
  • Compatibility Conflicts: None.
  • Corequisites: Requires 2042-001 with #9204.
  • Corequisites: Feature #9202 is required if only one 2042-001 is to
    be installed in the 2042-C40 Cabinet.
  • Compatibility Conflicts: Must have 2042-001 Director on same order.
  • Compatibility Conflicts: Must specifiy either #9201 or #9435 on each
    2042-C40 order.

    60c972
  • Field Installable: No.
  • Field Installable: No, IPO only.

    007a1020,1036

    (#9435) Plant Install N16 into CNT FC/9000 C40 Cabinet


    Specify this feature in your initial order of the CNT FC/9000 Cabinet
    to designate that the CNT UltraNet Multi-service Director will be plant
    installed in a 2042-C40 Cabinet.


    • Minimum Number of Features per 2042-C40: None.
    • Maximum Number of Features per 2042-C40: Two.
    • Prerequisites: None.
    • Corequisites: Requires 2042-N16 with #9431.
    • Compatibility Conflicts: Must have 2042-N16 Director on same order.
    • Compatibility Conflicts: Must specifiy either #9201 or #9435 on each
      2042-C40 order.
    • Customer Setup: No.
    • Limitations: None.
    • Field Installable: No, IPO only.
    • Cable Order: None.


    170a1200,1202
    CNT FC/9000 Cabinet 2042 C40
    C40 Cabinet North America 7800
    C40 Cabinet International 7801

    776c1808

    (#5405) Fibre Channel Cable:


    (#5405) Fibre Channel Cable



    779c1811

    (#5425) Fibre Channel Cable:


    (#5425) Fibre Channel Cable



    782c1814

    (#5505) Fibre Channel Cable:


    (#5505) Fibre Channel Cable



    785c1817

    (#5525) Fibre Channel Cable:


    (#5525) Fibre Channel Cable



    788c1820

    (#5605) Fibre Channel Cable:


    (#5605) Fibre Channel Cable



    791c1823

    (#5625) Fibre Channel Cable:


    (#5625) Fibre Channel Cable



    137a2170,2198

    Features for 2042-C40 FC/9000 Cabinet


    (#7800) C40 Cabinet North America Shipping for CNT N16


    Specify this feature for North American shipping requirements (United
    States, Canada, Mexico).


    • Minimum Number of Features per 2042-C40: None.
    • Maximum Number of Features per 2042-C40: One.
    • Prerequisites: None.
    • Corequisites: None.
    • Compatibility Conflicts: None.
    • Customer Setup: No.
    • Limitations: None.
    • Field Installable: No, IPO only.
    • Cable Order: None.

    (#7801) C40 Cabinet International Shipping for CNT N16


    Specify this feature for countries requiring International shipping
    requirements.


    • Minimum Number of Features per 2042-C40: None.
    • Maximum Number of Features per 2042-C40: One.
    • Prerequisites: None.
    • Corequisites: None.
    • Compatibility Conflicts: None.
    • Customer Setup: No.
    • Limitations: None.
    • Field Installable: No, IPO only.
    • Cable Order: None.