IBM U.S. Sales Manual
Revised:  June 28, 2005.

Table of contents  Document options  IBM U.S. Product Life Cycle Dates Publications Abstract Features -- Specify/Special/Exchange Highlights Accessories Description Machine Elements Model Supplies Technical Description    
doprint  
 
IBM U.S. Product Life Cycle Dates
Type ModelAnnounced AvailableMarketing Withdrawn Service DiscontinuedReplaced By
7040-W42 2002/11/122002/12/13 - - -


 
Abstract

IBM UNIX systems consist of the IBM eServer pSeries and IBM RS/6000 product lines. Providing unprecedented value, these innovative systems feature IBM's leading-edge technology and run the top-rated UNIX operating system, AIX. This broad product line ranges from powerful workstations ideal for mechanical design; to mission-critical symmetric multiprocessing (SMP) servers for ERP, SCM, CRM, transaction processing, and Web serving; up to parallel RS/6000 SP systems that can handle demanding scientific and technical computing and business intelligence tasks. These platforms provide the power to create change and the flexibility to manage it, with thousands of applications that provide real value. More than 1,000,000 systems have shipped to over 135,000 businesses worldwide.

Model Abstract 7040-W42

The IBM 7040-W42 System Rack provides space for mounting system drawer components for pSeries 655 servers and 7040-61D I/O drawers. The Model W42 is a 24-inch rack that provides 42U of rack space.

The 7040-W42 utilizes a 350 V DC bulk power subsystem to provide power for the components within the rack. The bulk power subsystem incorporates redundant bulk power assemblies mounted in the front and rear sections of the top 8U of the rack.
Back to topBack to top
 

Highlights

Model Highlights 7040-W42

  • 24-inch rack provides 42U of rack space.

Back to topBack to top
 
Description

System Rack -- (7040-W42)

The IBM 7040-W42 System Rack provides space for mounting system drawer components for pSeries 655 servers and 7040-61D I/O drawers. The Model W42 is a 24-inch rack that provides 42U of rack space.

The 7040-W42 utilizes a 350 V DC bulk power subsystem to provide power for the components within the rack. The bulk power subsystem incorporates redundant bulk power assemblies mounted in the front and rear sections of the top 8U of the rack.

7040-W42 System Rack Configuration and Limitations

  • The 7040-W42 System Rack is a 24-inch rack with an integrated power subsystem to support the pSeries servers such as the pSeries 655 (7039-651). It provides 42U of rack space.

  • Over time, the 7040-W42 rack will be utilized in multi-rack clusters. Rack indicators (such as #4651) will be used to identify the racks within the cluster and specify the desired rack in which to place various rack mounted components.

  • The 7040-W42 rack must have door assemblies installed. The following door assemblies are available:

    • A sculptured black front door with copper accent (#6076) is available for the Model W42 rack, used in conjunction with the slim line rear door (#6078). This combination should be utilized for installations where system footprint is the primary consideration.

    • An sculpted black front acoustic door (#6119) is available for the Model W42 rack, used in conjunction with the acoustic rear door (#6079). This combination should be utilized for installations requiring a quieter environment.

  • If additional external communication and storage devices are required 7014-T00 or T42 racks should be utilized. There is no limit on the quantity of 7014 racks allowed.

  • The height of the 7040-W42 rack (42U) may require special handling when shipping by air or when moving under a low doorway.

  • The weight of the 7040-W42 rack (42U) may require special handling during movement to the customer installation.

  • The 7040-W42 rack incorporates two bulk power assemblies (#8690). These provide 350V DC power for devices located in the W42 rack. These bulk power assemblies are mounted in front and rear positions and occupy the top 8U of the rack. To provide optimum system availability these bulk power assemblies should be powered from separate power sources via separate line cords.

  • Bulk power regulators (#6186) interface to the bulk power assemblies to ensure proper power is supplied to the systems components. The number of bulk power regulators required is configuration dependent based on the number of CECs and I/O drawers installed. The following table provides the number of bulk power regulators required for each combination of CECs and I/O drawers.
                   Number of 7039-651 servers
           1   2   3   4   5   6   7   8   9  10  11  12  13  14  15  16
           -------------------------------------------------------------
Number
of     0   2   2   2   4   4   6   6   6   6(1)6   6(2)6   6   6   6   6
7040-
61D    1   2   2   2   4   4   6   6   6   6   6   6   6   6   6
plus
7045-  2       2   4   4   6   6   6   6(1)6   6(2)6   6
SW4
       3           4   6   6   6   6(1)6   6   6
       4               6   6   6   6   6
       5                   6   6(1)
Number of 7045-SW4           Number of BPRs
  1 through 6                      2
  7 thourgh 11                     4
  12                               4 (3)
  13 through 16                    6 (3)
 

Note: (1) Configurations above this limit require the (#8686 or #8687) - Line Cord with 100A plug, (#8677) - Line Cord with no plug, or (#8680) - Line Cord with 30A plug to maintain the redundant input power source/line cord condition. Customers have the option of continuing with the 60 Amp plug line cords, running in non-redundant mode for input power source/line cords. Customers also have the option of ordering any line cord at any time, regardless of configuration size. Two line cords are required per 7040-W42 rack, and these line cords must be identical features.

Note: (2) Configuration above this limit requires the (#6267) - Power Distribution Jumper Assembly, High Current. Rack configurations with this feature run in non-redundant mode for input power source/line cords.

Note: (3) Configurations above this limit require the (#8686 or #8687) - Line Cord with 100A plug, (#8677) - Line Cord with no plug, or (#8680) - Line Cord with 30A plug.

  • Two Power Controller features (#6187) are required for all pSeries 655 systems, one per bulk power assembly. The Power Controllers provides power connections to support up to three rack drawers (populated with p655 servers, 7040-61D I/O drawers, or a 7045-SW4 HPS switch.)

  • The Power Distribution Assembly (#6188) provides additional power connections to support up to five additional drawers within the primary rack. Two Power Distribution Assemblies (one per Bulk Power Assembly) are added as required within p655 system configurations.

  • Additional Power Distribution Assemblies (#6188) for the HPS multi-switch configuration support of the expansion rack (#8691) are required. With up to five drawers populated in the expansion rack, a total of four #6188 are required. Above five drawers, a total of six #6188 are required.

  • Optional Integrated Battery Backup is available, if desired. The primary and secondary battery backup features (#6200 and #6201) interface with the power controllers of the front and rear bulk power assemblies. The battery backup features protect against power line disturbances and provide sufficient power to allow an orderly system shutdown in the event that the power sources fail. The battery backup features require up to 6U of rack space and are always installed at the 13U location of the primary 7040-W42 rack.

  • p655 CECs and I/O drawers occupy specific locations in the 7040-W42 rack. Drawer placement is specified by the mounting location features ordered on the CEC or I/O drawer. The first p655 CEC is in Drawer #1. Additional drawers can have 7039-651 CECs, 7040-61D I/O, or IBF features of the 7040-W42 rack.

    • Drawer #1 - Placement indicator #4609 - 9U position of 7040-W42 rack

    • Drawer #2 - Placement indicator #4605 - 5U position of 7040-W42 rack

    • Drawer #3 - Placement indicator #4601 - 1U position of 7040-W42 rack

    • Drawer #4 - Placement indicator #4619 - 19U position of 7040-W42 rack

    • Drawer #5 - Placement indicator #4623 - 23U position of 7040-W42 rack

    • Drawer #6 - Placement indicator #4627 - 27U position of 7040-W42 rack

    • Drawer #7 - Placement indicator #4631 - 31U position of 7040-W42 rack

    • Drawer #8 - Placement indicator #4613 - 13U position of 7040-W42 rack
      • Placement indicator #4613 - 13U position of 7040-W42 rack if Integrated Battery Backup feature (#6200) is not installed.

  • The position of the p655 CEC within the node enclosure is identified by the Power Cable Group (#38xx) for left side or right side of the enclosure.

Back to topBack to top
 
Model

Model Summary Matrix

Model Description
W42 24-inch rack

Customer Setup (CSU)

None.

Devices Supported

Feature Availability Matrix

The following feature availability matrix for MT 7040 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Please check with your Marketing Representative for additional information.

        |W| A = AVAILABLE  S = SUPPORTED
        |4| N = NOT SUPPORTED, MUST BE REMOVED
        |2|
FEAT/PN | |        DESCRIPTION
--------|-|-----------------------------------------
0191    |A| Rack Content Specify: 7040/61D - 4U
0211    |A| Rack Content Specify: 7039/651 - 4U, Half Drawer
0212    |A| Rack Content Specify: 7045/SW4 - 4U
0986    |A| CCS Customer Service Specify (US)
3754    |A| Service Tool Kit
3755    |A| Service Ladder
3756    |A| Service Tool Kit, High Performance Switch
4651    |A| Rack Indicator, Rack #1
4653    |A| Rack Indicator, Rack #3
4654    |A| Rack Indicator, Rack #4
4655    |A| Rack Indicator, Rack #5
4656    |A| Rack Indicator, Rack #6
4657    |A| Rack Indicator, Rack #7
4658    |A| Rack Indicator, Rack #8
4659    |A| Rack Indicator, Rack #9
4660    |A| Rack Indicator, Rack #10
4661    |A| Rack Indicator, Rack #11
4662    |A| Rack Indicator, Rack #12
4663    |A| Rack Indicator, Rack #13
4664    |A| Rack Indicator, Rack #14
4665    |A| Rack Indicator, Rack #15
4666    |A| Rack Indicator, Rack #16
6070    |A| Front Door, Black with Copper Accent, Primary Rack
6071    |S| Front Door, Sculptured Black, Secondary Rack
6074    |S| Rear Door, Slim Line, Primary or Secondary Rack
6076    |S| Front Door, Black with Copper Accent, Primary Rack
6078    |S| Rear Door, Slim Line, Primary Rack
6079    |S| Rear Door, Acoustic, Primary Rack
6119    |S| Front Door, Acoustic, Primary Rack
6186    |A| Bulk Power Regulator
6187    |A| Power Controller, Four Cooling Fans, Three DC Power
        | |      Converter Connections
6188    |A| Power Distribution Assembly, Ten DC Power Converter
        | |      Connectors
6200    |A| Integrated Battery Backup, Primary
6201    |A| Integrated Battery Backup, Redundant
6234    |A| Frame Extender
6240    |A| Cable, Integrated Battery Backup to Bulk Power Regulator,
        | |      Primary Rack
6241    |S| Cable, Integrated Battery to Bulk Power Regulator,
        | |      Expansion Rack
6242    |A| Cable, Front Mounted Integrated Battery Backup to
        | |      rear BPR, Primary/Expansion Rack
6244    |S| EMC Skirts/Tailgate for 7040-W42
6267    |A| Power Distribution Jumper Assembly, High Current
8122    |A| Attachment Cables, Hardware Management Console to 7040-W42,
        | |      6-Meter
8123    |A| Attachment Cables, Hardware Management Console to 7040-W42,
        | |      15-Meter
8677    |A| Line Cord, 8AWG, 14ft, No Plug
8680    |A| Line Cord, 10AWG, 14ft, IEC309 Plug
8682    |A| Line Cord, 10AWG, 6ft, Chicago, IEC309 Plug
8686    |A| Line Cord, 6AWG, 14ft, IEC309 100A Plug
8687    |A| Line Cord, 6AWG, 6ft, IEC309 100A Plug
8688    |A| Line Cord, 6AWG/Type W, 14ft, IEC309 60A Plug
8689    |A| Line Cord, 6AWG/Type W, 6ft, IEC309 60A Plug
8690    |A| Bulk Power Assembly, Redundant
8691    |S| Expansion Rack, 24", 42U
8694    |A| Line Cord, 6AWG, 14ft, No Plug
9300    |A| Language Group Specify - US English
9703    |A| Language Group Specify - French
9704    |A| Language Group Specify - German
9705    |A| Language Group Specify - Polish
9707    |A| Language Group Specify - Portuguese
9708    |A| Language Group Specify - Spanish
9711    |A| Language Group Specify - Italian
9712    |A| Language Group Specify - Canadian French
9714    |A| Language Group Specify - Japanese
9715    |A| Language Group Specify - Traditional Chinese (Taiwan)
9716    |A| Language Group Specify - Korean
9718    |A| Language Group Specify - Turkish
9719    |A| Language Group Specify - Hungarian
9720    |A| Language Group Specify - Slovakian
9721    |A| Language Group Specify - Russian
9722    |A| Language Group Specify - Simplified Chinese (PRC)
9724    |A| Language Group Specify - Czech
 

Model Conversions

None.
Back to topBack to top
 
Technical Description
TOC Link Physical Specifications TOC Link Operating Environment TOC Link Limitations
TOC Link Hardware Requirements TOC Link Software Requirements

Physical Specifications

(7040-W42)(single rack):

  • Width:
    • 78.5 cm (30.9 in)(with acoustic doors)
    • 78.5 cm (30.9 in)(with slim-line doors)

  • Depth:
    • 179.9 cm (70.8 in)(with acoustic doors)
    • 144.3 cm (56.8 in)(with slim-line doors)

  • Height:
    • 202.5 cm (79.7 in)(with acoustic doors)
    • 202.5 cm (79.7 in) (with slim-line doors)

  • Weight: 1,652 kgs (3,635 lb maximum)(with acoustic doors)

Power Requirements

  • Operating voltage @ 50/60 Hz: (3-phase)
    • 200 to 240 V AC
    • 380 to 415 V AC
    • 480 V AC

Operating Environment

Not applicable.

Limitations

See the Description section.

Hardware Requirements

Not applicable.

Software Requirements

Not applicable.
Back to topBack to top
 
Publications

The following publications are shipped with the pSeries 655. Additional copies are available. To order, contact your IBM representative.

  • pSeries 655 Installation Guide (SA38-0616)
  • System Unit Safety Information (SA23-2652)
  • PCI Adapter Placement Reference (SA38-0538)

Refer to the Related Publications section of the "pSeries 655 Installation Guide" for information regarding other available pSeries 655 publications or on the Web, visit:

http://techsupport.services.ibm.com/eserver/ techKnow?expanded=pSeriespubs#pSeries

Back to topBack to top
 
Features -- Specify/Special/Exchange
TOC Link No Charge Specify Codes TOC Link Special Feature Codes -- Chargeable TOC Link Feature Exchanges

No Charge Specify Codes

  • LANGUAGES
    • (#9300) - Language Group Specify - US English
    • (#9703) - Language Group Specify - French
    • (#9704) - Language Group Specify - German
    • (#9705) - Language Group Specify - Polish
    • (#9707) - Language Group Specify - Portuguese
    • (#9708) - Language Group Specify - Spanish
    • (#9711) - Language Group Specify - Italian
    • (#9712) - Language Group Specify - Canadian French
    • (#9714) - Language Group Specify - Japanese
    • (#9715) - Language Group Specify - Traditional Chinese (Taiwan)
    • (#9716) - Language Group Specify - Korean
    • (#9718) - Language Group Specify - Turkish
    • (#9719) - Language Group Specify - Hungarian
    • (#9720) - Language Group Specify - Slovakian
    • (#9721) - Language Group Specify - Russian
    • (#9722) - Language Group Specify - Simplified Chinese (PRC)
    • (#9724) - Language Group Specify - Czech

  • MISCELLANEOUS
    • (#0986) - CCS Customer Service Specify (US)

  • SPECIFY CODES
    • (#0191) - Rack Content Specify: 7040/61D - 4U
    • (#0211) - Rack Content Specify: 7039/651 - 4U, Half Drawer
    • (#4651) - Rack Indicator, Rack #1
    • (#4652) - Rack Indicator, Rack #2
    • (#4653) - Rack Indicator, Rack #3
    • (#4654) - Rack Indicator, Rack #4
    • (#4655) - Rack Indicator, Rack #5
    • (#4656) - Rack Indicator, Rack #6
    • (#4657) - Rack Indicator, Rack #7
    • (#4658) - Rack Indicator, Rack #8
    • (#4659) - Rack Indicator, Rack #9
    • (#4660) - Rack Indicator, Rack #10
    • (#4661) - Rack Indicator, Rack #11
    • (#4662) - Rack Indicator, Rack #12
    • (#4663) - Rack Indicator, Rack #13
    • (#4664) - Rack Indicator, Rack #14
    • (#4665) - Rack Indicator, Rack #15
    • (#4666) - Rack Indicator, Rack #16

Special Feature Codes -- Chargeable

  • POWER
    • (#6187) - Power Controller, Four Cooling Fans, Three DC Power Converter Connections

  • RACK RELATED
    • (#8690) - Bulk Power Assembly, Redundant
    • (#6070) - Front Door, Black with Copper Accent, Primary Rack
    • (#6076) - Front Door, Black with Copper Accent, Primary Rack
    • (#6079) - Rear Door, Acoustic, Primary Rack
    • (#6119) - Front Door, Acoustic, Primary Rack

Special Features - Plant and/or Field Installable

  • CABLES
    • (#8122) - Attachment Cables, Hardware Management Console to 7040-W42, 6-Meter
    • (#8123) - Attachment Cables, Hardware Management Console to 7040-W42, 15-Meter

  • POWER
    • (#6186) - Bulk Power Regulator
    • (#6188) - Power Distribution Assembly, Ten DC Power Converter Connectors
    • (#6200) - Integrated Battery Backup, Primary
    • (#6201) - Integrated Battery Backup, Redundant
    • (#6241) - Cable, Integrated Battery to Bulk Power Regulator, Expansion Rack
    • (#6242) - Cable, Front Mounted Integrated Battery Backup to rear BPR, Primary/Expansion Rack
    • (#6267) - Power Distribution Jumper Assembly, High Current
    • (#6240) - Cable, Integrated Battery Backup to Bulk Power Regulator, Primary Rack

  • LINECORDS
    • (#8677) - Line Cord, 8AWG, 14ft, No Plug
    • (#8680) - Line Cord, 10AWG, 14ft, IEC309 Plug
    • (#8682) - Line Cord, 10AWG, 6ft, Chicago, IEC309 Plug
    • (#8686) - Line Cord, 6AWG, 14ft, IEC309 100A Plug
    • (#8687) - Line Cord, 6AWG, 6ft, IEC309 100A Plug
    • (#8688) - Line Cord, 6AWG/Type W, 14ft, IEC309 60A Plug
    • (#8689) - Line Cord, 6AWG/Type W, 6ft, IEC309 60A Plug
    • (#8694) - Line Cord, 6AWG, 14ft, No Plug

  • MISCELLANEOUS
    • (#3754) - Service Tool Kit
    • (#3755) - Service Ladder
    • (#3756) - Service Tool Kit, High Performance Switch

  • RACK RELATED
    • (#6071) - Front Door, Sculptured Black, Secondary Rack
    • (#6074) - Rear Door, Slim Line, Primary or Secondary Rack
    • (#6078) - Rear Door, Slim Line, Primary Rack
    • (#6234) - Frame Extender
    • (#8691) - Expansion Rack, 24", 42U

  • SPECIFY CODES
    • (#0212) - Rack Content Specify: 7045/SW4 - 4U

Feature Descriptions

(#0191) Rack Content Specify: 7040/61D - 4U

Indicator of rack space utilization for 7040/61D I/O Drawer

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7040-W42: (#0191)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#0211) Rack Content Specify: 7039/651 - 4U, Half Drawer

Indicator of rack space utilization for 7039/651 CEC.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space in one half drawer
  • For 7040-W42: (#0211)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#0212) Rack Content Specify: 7045/SW4 - 4U

Indicator of rack space utilization for 7045/SW4.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7040-W42: (#0212)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: When used with the p655 system, the 0212 is limited to the bottom drawer location in the rack, in a quantity of one.

(#0986) CCS Customer Service Specify (US)

This feature code specifies that the system will receive special request services from the Center for Customized Solutions (CCS).

FC 0986 is available only on the initial plant order.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#0986)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#3754) Service Tool Kit

This feature delivers the Service Took Kit and Service Tray for the p655 server. Remove this feature from additional 7040-W42 rack orders with 7039-651 p655 CECs to prevent multiple quantities of the Tool Kit and Service Tray from being shipped. Every p655 installation location must have access to one Service Tool Kit/Service Tray. Failure to have at least one available in a location may result in delayed or prolonged maintenance times.

  • Attributes provided: Service Tool Kit/Service Tray for 7039-651
  • Attributes required: 7040-W42 rack with a 7039-651 p655 CEC
  • For 7040-W42: (#3754)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The Service Tool Kit/Service Tray FC 3754 should be assigned once when the FC 0211 (Rack Content Specify - 7039-651) is ordered on the 7040-W42. FC 3754 can be removed from the order to prevent multiple shipment of Service Took Kits per installation.

(#3755) Service Ladder

This feature delivers the Service Ladder for components within the higher drawers of the 7040-W42 rack. Remove this feature from additional 7040-W42 rack orders to prevent multiple quantities of the Service Ladder from being shipped. Also remove this feature if RPQ 8A1173 "Compact Handling Option" is ordered. Every 7040-W42 installation location with components within the higher drawers of the rack must have access to one Service Ladder. Failure to have at least one available in a location may result in delayed or prolonged maintenance times.

  • Attributes provided: Service Ladder for 7040-W42
  • Attributes required: 7040-W42 rack
  • For 7040-W42: (#3755)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The Service Ladder FC 3755 should be assigned once when the FC 3803 is ordered, as either an initial order or an MES. FC 3755 can be removed from the order to prevent multiple shipment of Service Ladders per installation. The FC should be removed from the initial order if RPQ 8A1173 Compact Handling Option is ordered.

(#3756) Service Tool Kit, High Performance Switch

This feature delivers the Service Took Kit for the High Performance Switch. Remove this feature from additional 7045-SW4 orders to prevent multiple quantities of the Tool Kit from being shipped. Every installation location with an HPS 7045-SW4 must have access to one Service Tool Kit. Failure to have at least one available in a location may result in delayed or prolonged maintenance times.

  • Attributes provided: Service Tool Kit for 7045-SW4
  • Attributes required: 7045-SW4
  • For 7040-W42: (#3756)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The Service Tool Kit FC 3756 should be assigned once when the FC 0212 (Rack Content Specify - 7045-SW4) is ordered on a 7040-61R or a 7040-W42. FC 3756 can be removed from the order to prevent multiple shipment of Service Took Kits per installation.

(#4651) Rack Indicator, Rack #1

This indicator is used to specify the first rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the first rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4651)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4652) Rack Indicator, Rack #2

This indicator is used to specify the second rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the second rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4652)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4653) Rack Indicator, Rack #3

This indicator is used to specify the third rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the third rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4653)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4654) Rack Indicator, Rack #4

This indicator is used to specify the fourth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fourth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4654)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4655) Rack Indicator, Rack #5

This indicator is used to specify the fifth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fifth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4655)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4656) Rack Indicator, Rack #6

This indicator is used to specify the sixth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the sixth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4656)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4657) Rack Indicator, Rack #7

This indicator is used to specify the seventh rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the seventh rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4657)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4658) Rack Indicator, Rack #8

This indicator is used to specify the eighth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the eighth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4658)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4659) Rack Indicator, Rack #9

This indicator is used to specify the ninth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the ninth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4659)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4660) Rack Indicator, Rack #10

This indicator is used to specify the tenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the tenth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4660)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4661) Rack Indicator, Rack #11

This indicator is used to specify the eleventh rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the eleventh rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4661)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4662) Rack Indicator, Rack #12

This indicator is used to specify the twelfth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the twelfth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4662)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4663) Rack Indicator, Rack #13

This indicator is used to specify the thirteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the thirteenth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4663)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4664) Rack Indicator, Rack #14

This indicator is used to specify the fourteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fourteenth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4664)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4665) Rack Indicator, Rack #15

This indicator is used to specify the fifteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the fifteenth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4665)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4666) Rack Indicator, Rack #16

This indicator is used to specify the sixteenth rack of a multi rack complex. It is also used to specify that a rack mounted device (such as an I/O drawer) is to be mounted in the sixteenth rack of a multi rack complex.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7040-W42: (#4666)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6070) Front Door, Black with Copper Accent, Primary Rack

This feature provides a sculptured black front door with copper accent for installation on the primary rack containing the system CEC (Central Electronics Complex).

  • Attributes provided: Front Door for Primary System Rack
  • Attributes required: None
  • For 7040-W42: (#6070)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#6071) Front Door, Sculptured Black, Secondary Rack

(No Longer Available as of December 10, 2004)

This feature provides a sculptured black front door for installation on a secondary rack which does not contain a system CEC (Central Electronics Complex).

  • Attributes provided: Front Door for Secondary Rack
  • Attributes required: None
  • For 7040-W42: (#6071)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: This feature is available via MES only when ordering a #8691 Expansion Rack Feature via MES.

(#6074) Rear Door, Slim Line, Primary or Secondary Rack

(No Longer Available as of November 18, 2005)

This feature provides a black rear door for installation on the primary rack containing the system CEC (Central Electronics Complex) or on a secondary rack. This door provides a minimized footprint for use in environments where conservation of space is required.

  • Attributes provided: Rear Door for Primary System Rack
  • Attributes required: None
  • For 7040-W42: (#6074)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6076) Front Door, Black with Copper Accent, Primary Rack

(No Longer Available as of November 18, 2005)

This feature provides a sculptured black front door with copper accent for installation on the primary rack containing the system CEC (Central Electronics Complex).

  • Attributes provided: Front Door for Primary System Rack
  • Attributes required: None
  • For 7040-W42: (#6076)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The #6076 front door is used with the #6078 slim line rear door. One #6076 or #6119 (Acoustic) front door is required for each system.

(#6078) Rear Door, Slim Line, Primary Rack

(No Longer Available as of November 18, 2005)

This feature provides a black rear door for installation on the primary rack containing the system CEC (Central Electronics Complex). This door provides a minimized footprint for use in environments where conservation of space is required.

  • Attributes provided: Rear Door for Primary System Rack
  • Attributes required: None
  • For 7040-W42: (#6078)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: One #6078 (Slim line) or #6079 (Acoustic) back door is required per system.

(#6079) Rear Door, Acoustic, Primary Rack

(No Longer Available as of November 18, 2005)

This feature provides a rear black door for installation on a primary rack which contains a system CEC (Central Electronics Complex). This door provides additional acoustic dampening for use where a quieter environment is desired.

  • Attributes provided: Rear Acoustic Door for primary Rack
  • Attributes required: None
  • For 7040-W42: (#6079)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: One #6079 (Acoustic) or #6078 (Slim line) back door is required per system.

(#6119) Front Door, Acoustic, Primary Rack

(No Longer Available as of November 18, 2005)

This feature provides a sculptured black front acoustic door with copper accent for installation on the primary rack containing the system CEC (Central Electronics Complex).

  • Attributes provided: Front Acoustic Door for Primary System Rack
  • Attributes required: None
  • For 7040-W42: (#6119)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The #6119 front door is used with the #6079 acoustic rear door. One #6119 (Acoustic) or #6076 front door is required for each system.

(#6186) Bulk Power Regulator

Bulk power regulators provide increments of power for use by the systems components such as fans, CEC components, and I/O drawers.

  • Attributes provided: Regulated Power
  • Attributes required: Bulk power assembly.
  • For 7040-W42: (#6186)
    • Minimum required: 2
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6187) Power Controller Assembly

This power controller provides the base power connections for the internal power cables.

  • Attributes provided: Base power connections for internal power cables.
  • Attributes required:
  • For 7040-W42: (#6187)
    • Minimum required: 2
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: AIX
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

    Note: Two #6187 Power Controllers provides power connections to support up to three rack drawers in the 7040-W42 rack.

(#6188) Power Distribution Assembly, Ten DC Power Converter Connectors

This Power distribution assembly provides ten connector locations for cable attachment of I/O drawer and CEC DC power converters.

  • Attributes provided: 10 power connectors
  • Attributes required: none
  • For 7040-W42: (#6188)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: The initial order maximum of #6188 is two for p655 configurations.

(#6200) Integrated Battery Backup, Primary

The Primary Integrated Battery Backup features provide batteries to be connected to the bulk power regulators of the front bulk power assembly. These batteries protect against power line disturbances as well as power failures involving both redundant power sources or the front power source and the rear bulk power assembly. The batteries provide sufficient backup power to allow an orderly system shutdown.

  • Attributes provided: Integrated Battery Backup
  • Attributes required: 2U Rack Space
  • For 7040-W42: (#6200)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: When Primary Integrated Battery Backup feature(s) are ordered, one is required for each Bulk Power Regulator (#6186) in the front bulk power assembly.

(#6201) Integrated Battery Backup, Redundant

The Redundant Integrated Battery Backup features provide batteries to be connected to the bulk power regulators of the rear bulk power assembly. These batteries protect against power line disturbances as well as power failures involving both redundant power sources. They also protect against failure of both power sources at the same time as a failure of the primary battery backup or the front bulk power assembly. The batteries provide sufficient backup power to allow an orderly system shutdown.

  • Attributes provided: Redundant Integrated Battery Backup
  • Attributes required: Primary Integrated Battery Backup Feature
  • For 7040-W42: (#6201)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: AIX ?.?
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: When Redundant Integrated Battery Backup features are ordered, one is required for each Bulk Power Regulator (#6186) in the rear bulk power assembly.

(#6234) Frame Extender

This frame extender feature provides cable management for the 7040-W42 in the non-CEC, multi drawer application, when 3 or more drawers are installed. The frame extender can also be ordered with less than three drawers to ease upgrade rework. If the expansion rack #8691 is in the configuration, it also requires a frame extender #6234 if there is a Frame Extender (#6234) on the 7040-W42 rack.

  • Attributes provided: Frame extender for cable management
  • Attributes required: Non-CEC version of 7040-W42 or #8691 on 7040-W42 Rack.
  • For 7040-W42: (#6234)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: For non-CEC applications of the 7040-W42 with 3 or more drawers, #6234 is assigned by the configurator. If there are more than 2 HPSs and fewer than 32 copper cables within the multi-switch rack application, then the Frame Extender (#6234) may be deselected in the configurator. This is to allow large configurations with a high density of fiber cables to minimize the multi-switch rack footprint.

(#6240) Cable, Integrated Battery Backup to Bulk Power Regulator, Primary Rack

This cable provides a connection between the integrated battery backup features located in the primary rack and the bulk power regulators located in the front and rear bulk power assemblies. One cable is required for each primary and redundant integrated battery backup feature installed in the primary rack.

  • Attributes provided: Battery Backup Attachment Cable
  • Attributes required: Primary or Redundant Integrated Battery Backup Features.
  • For 7040-W42: (#6240)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: In non-CEC multi drawer applications, the quantity is limited to 2.

(#6241) Cable, Integrated Battery to Bulk Power Regulator, Expansion

(No Longer Available as of December 10, 2004) Rack

.This cable provides a connection between the integrated battery backup features located in the expansion rack and the bulk power regulators located in the front and rear bulk power assemblies. One cable is required for each primary and redundant integrated battery backup feature installed in the expansion rack.

  • Attributes provided: Battery Backup Attachment Cable
  • Attributes required: Primary or Redundant Integrated Battery Backup Features.
  • For 7040-W42: (#6241)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6242) Cable, Front Mounted Integrated Battery Backup to rear BPR,

Primary/Expansion Rack

This cable provides a connection between the front mounted integrated battery backup features (#6200)located in the primary and expansion rack and the bulk power regulators located in the rear bulk power assemblies.

  • Attributes provided: Battery Backup Attachment Cable
  • Attributes required: Front Mounted Integrated Battery Backup Feature connected to rear Bulk Power Regulator.
  • For 7040-W42: (#6242)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6244) EMC Skirts/Tailgate for 7040-W42

(No Longer Available as of November 18, 2005)

#6244 is used when the High Performance Switch, 7045-SW4, is installed in the rack type 7040-W42 in EIA position #4601. It is also used for rack configurations that have the p655 server SNI feature #6420. #6244 drives the rack level EMC skirts/tailgate parts for the 7040-W42. For multiple switch applications, if there is an expansion rack #8691 without the frame extender #6234, then the expansion rack also requires a #6244.

  • Attributes provided: EMC Skirts/Tailgate for 7040-W42
  • Attributes required: 7045-SW4 or #6420
  • For 7040-W42: (#6244)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6267) Power Distribution Jumper Assembly, High Current

This feature provides a power distribution jumper assembly and cables for high current applications to enable the power output load sharing at the frame level.

  • Attributes provided: Power Distribution Jumper assembly/cables
  • Attributes required: High current frame configuration
  • For 7040-W42: (#6267)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8120) Attachment Cable, Hardware Management Console to Host, 6-Meter

This 6-meter cable provides an asynch connection between the HMC (Hardware Management Console) and the host system. It provides a 9-pin female connector for HMC connection and a 9-pin male connection to attach to the HMC port on the host system. A 9-pin to 25-pin adapter is also provided.

  • Attributes provided: 6-meter HMC attachment cable
  • Attributes required: Empty 9-pin asynch port on HMC
  • For 7040-W42: (#8120)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8121) Attachment Cable, Hardware Management Console to Host, 15-Meter

This 15-meter cable provides an asynch connection between the HMC (Hardware Management Console) and the host system. It provides a 9-pin female connector for HMC connection and a 9-pin male connection to attach to the HMC port on the host system. A 9-pin to 25-pin adapter is also provided.

  • Attributes provided: 15-meter HMC attachment cable
  • Attributes required: Empty 9-pin asynch port on HMC
  • For 7040-W42: (#8121)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8122) - ATTACHMENT CABLES, HARDWARE MANAGEMENT CONSOLE TO 7040-W42/61R, 6-Meter

These 6-meter cables provide an asynch connection between the HMC (Hardware Management Console) and the7040-W42 or 7040-61R power system. A pair of RS-422 to EIA 232 converters are included with this feature.

  • Attributes provided: Two 6-meter HMC attachment cables and two RS-422 to EIA 232 converters.
  • Attributes required: Two empty RS-422 asynch ports attached to an HMC, or two empty EIA 232 asynch ports attached to an HMC.
  • For 7040-W42: (#8122)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8123) - ATTACHMENT CABLES, HARDWARE MANAGEMENT CONSOLE TO 7040-W42/61R, 15-Meter

These 15-meter cables provide an asynch connection between the HMC (Hardware Management Console) and the 7040-W42 or 7040-61R power system. A pair of RS-422 to EIA 232 converters are included with this feature.

  • Attributes provided: Two 15-meter HMC attachment cables and two RS-422 to EIA 232 converters.
  • Attributes required: Two empty RS-422 asynch ports attached to an HMC, or two empty EIA 232 asynch ports attached to an HMC.
  • For 7040-W42: (#8123)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8677) Line Cord, 8AWG, 14ft, No Plug

This feature provides a 14 ft 8AWG line cord with no plug. It may be utilized for 200-415V circuits at loadings up to 40 A.

  • Attributes provided: 14 ft Line Cord with No Plug
  • Attributes required: None
  • For 7040-W42: (#8677)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: This line cord is not approved for use in the United States or Canada.

(#8680) Line Cord, 10AWG, 14ft, IEC309 Plug

This feature provides a 14 ft, 10AWG line cord equipped with an IEC 309 plug. It may be utilized for 30A, 480VAC circuits.

  • Attributes provided: 14 ft Line Cord with IEC309 Plug
  • Attributes required: None
  • For 7040-W42: (#8680)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8682) Line Cord, 10AWG, 6ft, Chicago, IEC309 Plug

This feature provides a 6 ft, 10AWG line cord equipped with an IEC 309 plug. It may be utilized for 30A, 480VAC circuits.

  • Attributes provided: 6 ft Line Cord with IEC309 Plug
  • Attributes required: None
  • For 7040-W42: (#8682)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8686) Line Cord, 6AWG, 14ft, IEC309 100A Plug

This feature provides a 14 ft, 6AWG line cord equipped with an IEC309 100A plug. It provides connection to an 80A, 240VAC circuit.

  • Attributes provided: 14 ft line cord with IEC309 100A plug
  • Attributes required: None
  • For 7040-W42: (#8686)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Refer to the Rack and Power table for configuration application requirements of this line cord. Site Planning for future growth should also be considered to avoid the upgrade of the #8688 (Line Cord with 60 A plug) to the #8686 (Line Cord with 100 A plug.)

(#8687) Line Cord, 6AWG, 6ft, IEC309 100A Plug

This feature provides a 6 ft, 6AWG line cord equipped with an IEC309 100A plug. It provides connection to an 80A, 240VAC circuit.

  • Attributes provided: 6 ft line cord with IEC309 100A plug
  • Attributes required: None
  • For 7040-W42: (#8687)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Refer to the Rack and Power table for configuration application requirements of this line cord. Site Planning for future growth should also be considered to avoid the upgrade of the #8689 (Line Cord with 60 A plug) to the #8687 (Line Cord with 100 A plug.)

(#8688) Line Cord, 6AWG/Type W, 14ft, IEC309 60A Plug

This feature provides a 14 ft, 6AWG/Type W line cord equipped with a 60A IEC309 plug. It provides connection to a 60A, 240VAC circuit.

  • Attributes provided: 14 ft line cord with 60A IEC309 plug
  • Attributes required: None
  • For 7040-W42: (#8688)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Refer to the Rack and Power table for configuration application requirements of this line cord. Site Planning for future growth should also be considered to avoid the upgrade of the #8688 (Line Cord with 60 A plug) to the #8686 (Line Cord with 100 A plug.)

(#8689) Line Cord, 6AWG/Type W, 6ft, IEC309 60A Plug

This feature provides a 6 ft, 6AWG/Type W line cord equipped with a 60A IEC 309 plug. It may be utilized for 60A, 240VAC circuits.

  • Attributes provided: 6 ft Line Cord with 60A IEC309 Plug
  • Attributes required: None
  • For 7040-W42: (#8689)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Refer to the Rack and Power table for configuration application requirements of this line cord. Site Planning for future growth should also be considered to avoid the upgrade of the #8689 (Line Cord with 60 A plug) to the #8687 (Line Cord with 100 A plug.)

(#8690) Bulk Power Assembly, Redundant

This feature provides two bulk power assemblies for redundant power. These bulk power assemblies mount in the front and the back of the primary rack and utilize 8U of space.

  • Attributes provided: Redundant Bulk Power
  • Attributes required: 8U Rack Space
  • For 7040-W42: (#8690)
    • Minimum required: 1
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#8691) Expansion Rack, 24", 42U

(No Longer Available as of December 10, 2004)

This expansion rack feature provides an additional 42U of 24" rack space. When installed, one side cover of the 7040-61R rack is removed, the expansion rack is bolted to the 7040-61R rack, and the side cover is placed on the expansion rack. Devices mounted in the expansion rack feature utilize power provided by the base 7040-61R rack. #8691 is also available on the 7040-W42 in the non-CEC, multi drawer application.

  • Attributes provided: 42U of 24" Rack Space
  • Attributes required: 7040-61R or 7040-W42 Rack
  • For 7040-W42: (#8691)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: #8691 on the 7040-W42 is only available with the non-CEC version of the primary rack 7040-W42.

(#9300) Language Group Specify - US English

English language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9300)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#8694) Line Cord, 6AWG, 14ft, No Plug

This feature provides a 14 ft 6AWG line cord with no plug. It may be utilized for 200-415V circuits at loadings up to 63A.

  • Attributes provided: 14 ft Line Cord with No Plug
  • Attributes required: None
  • For 7040-W42: (#8694)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: This line cord is not approved for use in the United States or Canada.

(#9703) Language Group Specify - French

French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9703)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9704) Language Group Specify - German

German language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9704)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9705) Language Group Specify - Polish

Polish language group for Nomenclature and Standard Publications.

  • Attributes provided: none
  • Attributes required: none
  • For 7040-W42: (#9705)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9707) Language Group Specify - Portuguese

Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9707)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9708) Language Group Specify - Spanish

Spanish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9708)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9711) Language Group Specify - Italian

Italian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9711)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9712) Language Group Specify - Canadian French

Canadian French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9712)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9714) Language Group Specify - Japanese

Japanese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9714)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9715) Language Group Specify - Traditional Chinese (Taiwan)

Traditional Chinese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9715)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9716) Language Group Specify - Korean

Korean language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9716)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9718) Language Group Specify - Turkish

Turkish language group for nomenclature and publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9718)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9719) Language Group Specify - Hungarian

Hungarian language group for Nomenclature and Standard Publications.

  • Attributes provided: none
  • Attributes required: none
  • For 7040-W42: (#9719)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9720) Language Group Specify - Slovakian

Slovakian language group for Nomenclature and Standard Publications.

  • Attributes provided: none
  • Attributes required: none
  • For 7040-W42: (#9720)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9721) Language Group Specify - Russian

Russian language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9721)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9722) Language Group Specify - Simplified Chinese (PRC)

Simplified Chinese language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9722)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9724) Language Group Specify - Czech

Czech language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7040-W42: (#9724)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

Feature Exchanges

Not available.
Back to topBack to top
 
Accessories

None.

Customer Replacement Parts

None.
Back to topBack to top
 
Machine Elements

None.
Back to topBack to top
 
Supplies

None.

Diskettes

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Windows is a trademark of Microsoft Corporation.

UNIX is a registered trademark in the United States and other countries licensed exclusively through X/Open Company Limited.
 © IBM Corporation 2005.
Back to topBack to top