Attached System Types
The following specify codes indicate the attached system types. They
are used to determine how microcode updates will be distributed and may
be changed at any time.
- #9000 Attached to S/390 or zSeries system
Power Cords
The appropriate Model A14 power cord is attached at the factory based
on the order destination country code except for the following:
- #9986 6 ft. Chicago power cord. Plant or field installable
Additional Specify Codes
(#9010) Attach to a 3495 Model B16
(For IBM US, No Longer Available as of April 24, 1998)
This specify code was never shipped.
(#9012) Install A14 in 3495
This specify code allows the factory build of a new Model A14 for
installation in a 3495 Tape Library. This will provide a Model A14 with
the proper front panel for the four 3590 Model B1A Tape Drives in the
Model A14 and interface hardware to the 3495 Tape Library.
Maximum: One. Field Installation: No.
(#9062) Multiframe SCSI Drives - Plant Install
This feature provides the plant installation to support SCSI
attachment of 3590 Tape Drives in one 3590 Model A14 Frame to a 3590
Model A60 or 3592 Model J70 Controller in a different Model A14 Frame.
In a multiframe SCSI attachment, up to eight 3590 Tape Drives can be
attached to the 3590 Model A60 or 3592 Model J70 Controller, four in each
3590 Model A14 Frame. It includes SCSI cables between the two Model A14
Frames and allows for the proper drive-to-drive cables to be included
based on the number of drives installed in this frame. Because of SCSI
cable length restrictions, the two Model A14 Frames must be installed
adjacent to each other.
Maximum: One. Minimum: None. Plant Installation Only.
Prerequisites:
- There must be at least one tape drive installed in the Model A14
Frame with this feature.
- Feature #4060 must be installed on the associated other Model A14
Frame containing the 3590 Model A60 or 3592 Model J70 Controller.
- This feature cannot be ordered with a controller feature #9657,
#9658, #9667, #9668, #9867, or #9868.
(#9511) Factory Install Fibre Drive
This feature tells the factory to install one 3590 Model E11 Tape
Drive with the Fibre Channel Attachment feature into a new 3590 Model A14
frame coming from the plant. The tape drive must have a corresponding
feature #9510 (Fibre Channel Attachment - Plant Install), specified
instead of feature #9663 (Plant Install Drive) for the plant to install
the proper tape drive. The quantity of feature #9511 on the 3590 Model
A14 frame order must equal the number of 3590 Model E11 Tape Drives with
Fibre Channel Attachment that are being installed by the factory in that
frame.
Maximum: Four. This feature is mutually exclusive with features
#9630, #9631, and #9663. Field Installation: No.
(#9630) Field Merge B11 or E11 Drive in a Model A14 Frame
This specify code on the Model A14 allows the field merge of a 3590
Model B11 or E11 Tape Drive into a Model A14 coming from the plant. It
notifies the factory to leave a mounting slot available for a field merge
of the tape drive prior to completion of installation. All tape drives
attached to a controller in a Model A14 must be the same model (i.e.
either all E Model tape drives or all B Model tape drives). This feature
cannot be installed on an A14 with features #9638, #9639, or #4638.
Maximum: Four. Field Installation: No. The maximum of features
#9630 plus #9631 plus #9663 plus #4630 plus #4663 is four.
(#9631) Plant Install Drive in A14
This specify code allows the factory installation of a new Model B11
into a new Model A14 coming from the plant. This code must appear on
both the Model B11 and A14 orders. This feature cannot be installed on
an A14 with features #9638, #9639, or #4638.
Maximum: Four. Field installation: No. The maximum of features
#9030 plus #9031 plus #4630 is four.
(#9637) Plant Install Model A00 controller in a Model A14 frame
(Withdrawn from marketing)
This specify code allows the factory installation of a new Model A00
controller into a new Model A14 frame from the plant. This code must
appear on both the Model A00 and Model A14 orders.
Maximum: One. Field installation: No. The maximum or feature #4657
plus #9637 plus #9657 is two.
(#9638) Plant Install B1A Drive in A14
This specify code allows the factory installation of a new Model B1A
into a new Model A14 coming from the plant. This code must appear on
both the Model B1A and A14 orders. This feature cannot be installed on
an A14 with features #9630, #9631, #9663, or #4630.
Maximum: Four. Field installation: No. The sum of features #9638, #
9639, and #4638 must be four.
(#9639) Field Merge B1A in A14
This specify code on the Model A14 allows the field merge of a Model
B1A into a Model A14 coming from the plant. It notifies the factory to
leave a mounting slot available for a field merge of the Model B1A drive
prior to completion of installation. This feature cannot be installed on
an A14 with features #9630, #9631, #9663, or #4630.
Maximum: Four. Field installation: No. The sum of features #9638, #
9639, and #4638 must be four.
(#9657) Plant Install Model A50 controller in a Model A14 frame
(For IBM US, No Longer Available as of September 29, 2000)
This specify code allows the factory installation of a new Model A50
controller into a new Model A14 frame from the plant. This code must
appear on both the Model A50 and Model A14 orders.
Maximum: Two, unless feature #9012 is specified and then the maximum
is one. Field installation: No. The maximum of feature #4650 plus #4657
plus #9637 plus #9657 plus #9658 is two. This feature is mutually
exclusive with features #4660, #9667, or #9668.
(#9658) Field Merge Model A50 Controller in a Model A14 Frame
This specify code allows the field merge of a customer supplied 3590
Model A50 Controller into a new 3590 Model A14 Frame coming from the
plant. It notifies the factory to include the mounting hardware for the
field merge of the Model A50 prior to completion of installation of the
Model A14 Frame.
Maximum: Two. The maximum of feature #9658 plus #9657 plus #9637
plus #4650 plus #4657 is two. This feature is mutually exclusive with
features #9062, #9667, #9668, or #4660. Field installation: No.
(#9663) Plant Install Model E11 Drive in a Model A14 Frame
This specify code allows the factory installation of a new 3590 Model
E11 Tape Drive into a new Model A14 Frame coming from the plant. This
code must appear on both the Model E11 and A14 orders. This feature
cannot be installed on an A14 with features #9631, #9638, #9639, or
#4638.
Maximum: Four. Field installation: No. The maximum of features
#9630 plus #9663 plus #4630 is four.
(#9667) Plant Install Model A60 controller in a Model A14 frame
This specify code allows the factory merge of a new Model A60
controller into a new Model A14 frame from the plant. This code must
appear on both the Model A60 and Model A14 orders.
Maximum: One. The maximum of features #9667 plus #9668 plus #4660 is
one. This feature is mutually exclusive with features #9062, #9637,
#9657, #9658, #4650, or #4657. Field installation: No.
(#9668) Field Merge 3590 Model A60 in a 3590 Model A14 Frame
This specify code allows the field merge of a new 3590 Model A60
Controller into an installed 3590 Model A14 Frame.
Maximum: One. The maximum of features #9667 plus #9668 plus #4660 is
one. This feature is mutually exclusive with features #9062, #9637,
#9657, #9658, #4650, or #4657. Field installation: No.
(#9669) Plant Install 3590 Model H11 SCSI Tape Drive
This specify code allows the factory installation of a new Model H11
Tape Drive without the Fiber Channel Attachment feature (#9510 or #3510)
into a new Model A14 coming from the plant. This code must appear on
both the Model H11 and A14 orders. This feature cannot be installed on
an A14 with features #9630, #9631, #9638, #9639, #9663, or #9670.
Maximum: Four. The maximum of features #9669 plus #9672 plus #4669
plus #4672 is four.
Field installation: No.
(#9670) Plant Install 3590 Model H11 Fibre Channel Tape Drive
This specify code allows the factory installation of a new Model H11
Tape Drive with the Fiber Channel Attachment feature (#9510 or #3510)
into a new Model A14 coming from the plant. This code must appear on
both the Model H11 and A14 orders. This feature cannot be installed on
an A14 with features #9630, #9631, #9638, #9639, #9663, or #9669.
Maximum: Four. The maximum of features #9670 plus #9672 plus #4669
plus #4672 is four.
Field installation: No.
(#9672) Field Merge 3590 Model H11 Tape Drive in a Model A14 Frame
This specify code on the Model A14 allows the field merge of a 3590
Model H11 Tape Drive into a Model A14 coming from the plant. It notifies
the factory to leave a mounting slot available for a field merge of the
tape drive prior to completion of installation. All tape drives attached
to a controller in a Model A14 must be the same model (i.e. either all H
Model tape drives, all E Model tape drives, or all B Model tape drives).
This feature cannot be installed on an A14 with features #9630, #9631,
#9638, #9639, or #9663.
Maximum: Four. The maximum of features #9669 plus #9670 plus #9672
plus #4669 plus #4672 is four.
Field installation: No.
(#9780) Extended Media Support
This feature must be installed on any 3590 Model A14, C12, or C14 tape
subsystem if 3590 Extended High Performance Cartridge Tape is used in any
3590 Tape Drive in that subsystem. This feature provides the microcode
updates and maintenance information for the Extended Media Support
capability in that subsystem.
Maximum: One. Plant or Field installation.
(#9867) Plant Install 3592 Model J70 in a 3590 Model A14 Frame
This specify feature factory installs a new 3592 Model J70 Controller
into a new Model A14 frame from the plant. This feature must appear on
both the 3592 Model J70 and 3590 Model A14 orders.
- Maximum: One.
The maximum of features #9667 plus #9668 plus #9867 plus #9868 plus
#4660 plus #4860 plus #4868 is one. This feature is mutually exclusive
with features #9062, #9637, #9657, #9658, #9667, #9668, #4650, #4657, or
#4660.
- Field installation: No.
(#9868) Field Merge 3592 Model J70 in a 3590 Model A14 Frame
This specify feature notifies the plant that a 3592 Model J70
Controller will be field merged into a 3590 Model A14 Frame coming from
the plant, as part of the final customer installation.
- Maximum: One.
The maximum of features #9667 plus #9668 plus #9867 plus #9868 plus
#4660 plus #4860 plus #4868 is one. This feature is mutually exclusive
with features #9062, #9637, #9657, #9658, #9667, #9668, #4650, #4657, or
#4660.
- Field installation: No.
(#3464) Fibre Drive Attached Controller
This feature is required on the 3590 Model A14 Frame that contains a
3590 Model A60 or 3592 Model J70 Controller that supports attachment of
3590 Tape Drives with Fibre Channel Attachment (features #3510 or #9510).
It includes the required mounting hardware and instructions for
installing the IBM 2109 Model S16 SAN Fibre Channel Switch in the Model
A14, including the associated Ethernet hub and cabling between the 3590
Model A60 or 3592 Model J70 Controller and the hub and switch and drives
in that Model A14. Up to twelve 3590 Tape Drives in three Model A14
Frames can be attached to the 3590 Model A60 or 3592 Model J70
Controller.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Plant or Field Installation.
Prerequisites:
- Feature #3463 must be installed on the 3590 Model A60 Controller or
feature #3483 must be installed on the 3592 Model J70 Controller.
- All attaching 3590 Tape Drives must have either feature #3510 or
#9510.
- An IBM 2109 Model S16 SAN Fibre Channel Switch must be installed in
the rack or frame containing the 3590 Model A60 or 3592 Model J70
Controller.
Cables: Fibre Channel cables from the 3590 Tape Drives in other Model
A14 Frames to the switch are supplied with features #9064 (Multiframe
Fibre Drive - Plant) or #4064 (Multiframe Fibre Drive - Field) ordered on
the other Model A14 Frames containing any additional 3590 Tape Drives.
(#3474) LC Fibre Drive Attached Controller
This feature is required on the 3590 Model A14 Frame that contains a
3590 Model A60 or 3592 Model J70 Controller that supports attachment of
3590 Tape Drives with Fibre Channel Attachment (feature #3510 or #9510).
It includes the required mounting hardware and instructions for
installing the IBM 2109 SAN Fibre Channel Switch Model F16 in the Model
A14, including the associated Ethernet hub and cabling between the 3590
Model A60 or 3592 Model J70 Controller and the hub and switch and drives
in that Model A14. Up to twelve 3590 Tape Drives in three Model A14
Frames can be attached to the 3590 Model A60 or 3592 Model J70
Controller.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Plant or Field Installation.
Prerequisites:
- This feature is mutually exclusive with Model A14 feature #4060
(Multiframe SCSI A14) or #3464 (Fibre Drive Attached A60).
- Feature #3473 must be installed on the 3590 Model A60 Controller or
feature #3484 must be installed on the 3592 Model J70 Controller.
- All attaching 3590 Tape Drives must have either feature #3510 or
#9510.
- An IBM 2109 SAN Fibre Channel Switch Model F16 must be installed in
the rack or frame containing the 3590 Model A60 or or 3592 Model J70
Controller.
Cables: Fibre Channel cables from the 3590 Tape Drives in other Model
A14 Frames to the switch are supplied with feature or #4074 (LC
Multiframe Fibre Drive - Field) ordered on the other Model A14 Frames
containing any additional 3590 Tape Drives.
(#3486) 2Gb FC Drive Attach
This feature provides the mounting hardware for the 2Gb Fibre Channel
Switch on the 3590 Model A14 Frame that contains a 3592 Model J70
Controller that supports attachment of 3590 Tape Drives with Fibre
Channel Attachment (feature #3510 or #9510).
It includes the required mounting hardware and instructions for
installing a 2Gb Fibre Channel Switch in the Model A14, including
associated Ethernet hub and cabling between the 3592 Model J70
Controller and the hub and switch and drives in that Model A14.
Up to twelve 3590 Tape Drives in three Model A14 Frames
can be attached to the 3592 Model J70 Controller.
- Feature type: Chargeable
- Required feature: No
- Maximum number of features: One.
- Installation: Plant or Field
- Prerequisites: Feature #3487 or #4887 must be installed on the 3592
Model J70 Controller. This feature is mutually exclusive with
Features #3464, #3474 or #4060.
(#3490) Redundant 2Gb Fibre Channel Drive Attach
This feature provides the mounting hardware and instructions for
installing a second 2Gb Fibre Channel Switch in the 3590 Model A14 Frame.
- Feature type: Chargeable
- Required feature: No
- Maximum number of features: One
- Installation: Plant or Field
- Prerequisite: Feature #3486 must be installed on the
3590 Model A14 Frame.
(#4060) Multiframe SCSI A14
This feature is required on the 3590 Model A14 Frame that contains a
3590 Model A60 or 3592 Model J70 Controller to support SCSI attachment of
up to eight 3590 Tape Drives in two different Model A14 Frames. This
feature provides the necessary hardware and instructions for attachment
of up to four tape drives in another Model A14 Frame to the 3590 Model
A60 or 3592 Model J70 Controller in this frame. Because of SCSI cable
length restrictions, the two Model A14 Frames must be installed adjacent
to each other.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Plant or Field Installation.
(#4062) Multiframe SCSI Drives - Field Install
This feature provides the field installation to support SCSI
attachment of 3590 Tape Drives in one 3590 Model A14 Frame to a 3590
Model A60 Controller in a different Model A14 Frame. In a multiframe
SCSI attachment, up to eight 3590 Tape Drives can be attached to the
Model A60, four in each Model A14 Frame. It includes SCSI cables between
the two Model A14 Frames and allows for the proper drive-to-drive cables
to be included based on the number of drives installed in this frame.
Because of SCSI cable length restrictions, the two Model A14 Frames must
be installed adjacent to each other. If another controller is installed
in this Model A14 Frame, that controller will be non-functional.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Field Installation Only.
Prerequisites:
- There must be at least one tape drive installed in the Model A14
Frame with this feature.
- Feature #4060 must be installed on the associated other Model A14
Frame containing the 3590 Model A60 or 3592 Model J70 Controller.
(#4064) Multiframe Fibre Drives
This feature provides the hardware and installation instructions to
support attachment of 3590 Tape Drives with Fibre Channel Attachment
(features #3510 or #9510) in one 3590 Model A14 Frame to a 3590 Model A60
or 3592 Model J70 Controller in a different Model A14 Frame. In a
multiframe fibre attachment, up to 12 3590 Tape Drives with Fibre Channel
Attachment can be attached to the 3590 Model A60 or 3592 Model J70
Controller, four in each Model A14 Frame. This feature allows for a
Fibre Channel cable from each tape drive to the 2109 Model S16 switch in
the 3590 Model A14 Frame with the 3590 Model A60 or 3592 Model J70
Controller to be included based on the number of drives installed in this
frame. The distance between the two Model A14 frames in this multiframe
fibre configuration must be no more than 7 meters (23 feet). If another
controller is installed in this Model A14 Frame, that controller will be
non-functional.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Plant or Field Installation.
Prerequisites:
- There must be at least one tape drive installed in the Model A14
Frame with this feature.
- All the 3590 Tape Drives must have feature #3510 or #9510 (Fibre
Channel Attachment).
- Feature #3464 must be installed on the associated other Model A14
Frame containing the 3590 Model A60 or 3592 Model J70 Controller.
(#4074) LC Multiframe Fibre Drives
This feature provides the hardware and installation instructions to
support attachment of 3590 Tape Drives with Fibre Channel Attachment
(features #3510 or #9510) in one 3590 Model A14 Frame to a 3590 Model A60
or 3592 Model J70 Controller in a different Model A14 Frame. In a
multiframe fibre attachment, up to twelve 3590 Tape Drives with Fibre
Channel Attachment can be attached to the 3590 Model A60 or 3592 Model
J70 Controller, four in each Model A14 Frame. This feature allows for a
Fibre Channel cable from each tape drive to the 2109 Model F16 Switch in
the Model A14 Frame with the 3590 Model A60 or 3592 Model J70 Controller
to be included based on the number of drives installed in this frame.
The distance between the two Model A14 frames in this multiframe fibre
configuration must be no more than 7 meters (23 feet). If another
controller is installed in this Model A14 Frame, that controller will be
non-functional.
Maximum: One. Minimum: None. Only one of feature #3464, #3474,
#4060, #4062, #4064, #4074, or #9062 is allowed on each 3590 Model A14
Frame.
Plant or Field Installation.
Prerequisites:
- There must be at least one tape drive installed in the Model A14
Frame with this feature.
- All the 3590 Tape Drives must have feature #3510 or #9510 (Fibre
Channel Attachment).
- Feature #3474 must be installed on the associated other Model A14
Frame containing the 3590 Model A60 or 3592 Model J70 Controller.
(#4084) Multiframe 2Gb 3590
This feature provides the hardware and installation instructions
to support attachment of 3590 Tape Drives with Fibre Channel
Attachment (features #3510 or #9510) in one 3590 Model A14 Frame
to a 3592 Model J70 Controller in a different Model A14 Frame.
In a multiframe fibre attachment, up to twelve 3590 Tape Drives
with Fibre Channel Attachment can be attached to the 3592 Model J70
Controller, four in each Model A14 Frame. This feature allows for a
Fibre Channel cable from each tape drive to the 2Gb Fibre Channel
Switch in the Model A14 Frame with the 3592 Model J70 Controller to be
included based on the number of drives installed in this frame.
The distance between the two Model A14 Frames in this multiframe
fibre configuration must be no more than 7 meters (23 feet).
If another controller is installed in this Model A14 Frame, that
controller will be non-functional.
- Feature type: Chargeable
- Required feature: No
- Maximum number of features: Two.
- Installation: Plant or Field
- Prerequisites: One feature #3487 or #4887 must be ordered
on the Model J70 Controller in the adjacent frame for each of these
features ordered. This feature is mutually exclusive with
Features #3464, #3474, #4060, #4062, #4064, #4074 or #9062.
(#4630) Install Model B11 or E11 Drive in an Existing Model A14
This feature is required on a 3590 Model A14 to add a 3590 Model B11
or E11 Tape Drive to a currently installed Model A14 frame. All tape
drives attached to a controller in a Model A14 must be the same model
(i.e. either all E Model tape drives or all B Model tape drives). It
provides the mounting hardware for the drive and proper cables to connect
to the 3590 ESCON controller as determined by the number of feature #4630
plus #9630 plus #9631 plus #9663. This feature cannot be installed on an
A14 with features #9638, #9639, or #4638.
Maximum: Three. Optional. The maximum of features #9630 plus # 9631
plus #9663 plus #4638 is four. Field installation only.
(#4638) Install Model B1A in an Existing Model A14
This feature is required on a 3590 Model A14 to add a Model B1A drive
to a currently installed Model A14 frame. It provides the mounting
hardware for the drive. This feature cannot be installed on an A14 with
features #9630, #9631, or #4630.
Maximum: Four. The sum of features #9638, # 9639, and #4638 must be
four. Field installation only.
(#4650) Replace Model A00 with a Model A50
This feature is required to provide the mounting changes to replace a
3590 Model A00 Controller with a Model A50 Controller in a currently
installed Model A14 frame.
Maximum: Two. The maximum of features #4650 plus #4657 plus #9637
plus #9657 plus #9658 is two. This feature is mutually exclusive with
features #4660, #9667, or #9668. Field installation only.
(#4657) Field Install Model A50 Controller in an Existing Model A14 Frame
This feature is required to provide the mounting hardware to add a
Model A50 Controller to a currently installed Model A14 frame. This
feature is not available if feature #9012 is installed.
Maximum: Two. The maximum of features #4650 plus #4657 plus #9637
plus #9657 plus #9658 is two. This feature is mutually exclusive with
features #4660, #9667, or #9668. Field installation only.
(#4660) Replace Model A00 or A50 with a Model A60
This feature is required to provide the mounting changes to replace a
3590 Model A00 or A50 Controller with a Model A60 Controller in a
currently installed Model A14 frame.
Maximum: One. The maximum of features #4660 plus #9667 plus #9668 is
one. This feature is mutually exclusive with features #4650, #4657,
#9637, #9657, or #9658. Field installation only.
(#4663) Replace Model B11 Tape Drive with a Model E11
This feature is required to provide the mounting changes to replace a
3590 Model B11 Tape Drive with a Model E11 Tape Drive in a currently
installed Model A14 frame.
Maximum: Four. Optional. Field installation only.
(#4669) Replace Model B11 or E11 Tape Drive with a Model H11
This feature is required to provide the mounting changes to replace a
3590 Model B11 or E11 Tape Drive with a Model H11 Tape Drive in a
currently installed Model A14 frame. All tape drives attached to a
controller in a Model A14 must be the same model (i.e. either all H Model
tape drives, all E Model tape drives, or all B Model tape drives).
Maximum: Four. Optional. Field installation only.
(#4672) Field Install Model H11 Drive in a Model A14
This feature is required on a 3590 Model A14 to add a 3590 Model H11
Tape Drive to a currently installed Model A14 frame. All tape drives
attached to a controller in a Model A14 must be the same model (i.e.
either all H Model tape drives, all E Model tape drives, or all B Model
tape drives). It provides the mounting hardware for the drive and proper
cables to connect to the 3590 Model A60 Controller. This feature cannot
be installed on an A14 with features #9630, #9631, #9638, #9639, #9663,
#4630, #4638, or #4663.
Maximum: Three. Optional. The maximum of features #9669 plus #9670
plus #9672 plus #4669 plus #4672 is four.
Field installation only.
(#4730) Remove Tape Drive from a Model A14
This feature is to remove a 3590 Model B1A, B11, E11, or H11 Tape
Drive from a currently installed Model A14 frame for installation
elsewhere. One of feature #4630, #4638, #4663, #4669, #4672, #9630,
#9631, #9638, #9639, #9663, #9669, #9670, or #9672 must be removed when
this feature is added.
Maximum: Four. Optional. Field installation only.
(#4860) Replace Controller With a 3592 Model J70
This feature is required to provide the mounting changes to replace a
3590 Model A00, A50, or A60 Controller with a 3592 Model J70 Controller
in a currently installed Model A14 frame.
- Maximum: One.
The maximum of features #9667 plus #9668 plus #9867 plus #9868 plus
#4660 plus #4860 plus #4868 is one. This feature is mutually exclusive
with features #9062, #9637, #9657, #9658, #9667, #9668, #4650, #4657, or
#4660.
- Field Installation Only.
(#4868) Field Install 3592 Model J70 Controller in a Model A14
- This feature is required to provide the mounting hardware to add a
3592 Model J70 Controller to a currently installed Model A14 frame. This
feature is not available if feature #9012 is installed.
- Maximum: One.
The maximum of features #9667 plus #9668 plus #9867 plus #9868 plus
#4660 plus #4860 plus #4868 is one. This feature is mutually exclusive
with features #9062, #9637, #9657, #9658, #9667, #9668, #4650, #4657, or
#4660.
- Field Installation Only.
None.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None required with the machine order.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
© IBM Corporation 2004.
Back to top
|
|
|
|