IBM U.S. Sales Manual
Revised:  July 26, 2005.

Table of contents  Document options  IBM U.S. Product Life Cycle Dates Technical Description Abstract Publications Highlights Features -- Specify/Special/Exchange Description Accessories Product Positioning Machine Elements Models Supplies  
doprint  
 
IBM U.S. Product Life Cycle Dates
Type ModelAnnounced AvailableMarketing Withdrawn Service DiscontinuedReplaced By
2145-4F2 2003/06/032003/07/25 - - -


 
Abstract

The IBM 2145 TotalStorage SAN Volume Controller Storage Engines are the hardware elements of the IBM TotalStorage SAN Volume Controller, a member of the IBM TotalStorage Open Software Family of solutions. The SAN Volume Controller (SVC) combines servers into a high availability designed cluster. Each of the servers in the cluster is populated with 4 GB of high-speed memory which includes the cluster cache. The uninterruptible power supplies (UPSs) are designed to help protect against data loss resulting from a loss of electrical power. The SVC Storage Engines are always installed in pairs for redundancy.

A separate server provides a master console. The SAN Volume Controller master console software is preloaded on the master console and provides the user interface to the SAN Volume Controller. The master console can, using VPN, provide a Remote Support interface. This can help eliminate the requirement for frequent on-site support.

Model Abstract 2145-4F2

The IBM 2145 SAN Volume Controller Model 4F2 has dual 2.4 GHz, 2-way Intel Prestonia processors, 4 GB high speed memory, Uninterruptable Power Supplies (UPSs), and language support.
Back to topBack to top
 

Highlights

The SAN Volume Controller solution is designed to help reduce both the complexity and cost of managing your SAN-based storage.

The SAN Volume Controller is designed to allow you to:

  • Simplify management and increase administrator productivity by consolidating storage management intelligence from disparate storage controllers into a single view

  • Improve disaster recovery and business continuance capabilities by applying and managing copy services across disparate disk storage devices within the storage area network.

These solutions include a Common Information Model (CIM) Agent, enabling unified storage management based on open standards for units that comply with CIM Agent standards.
Back to topBack to top
 
Description

The IBM TotalStorage SAN Volume Controller is a storage virtualization system that incorporates highly specialized software, control engines (SVC Storage Engines) installed in pairs, a master console, and UPSs. The SAN Volume Controller hardware configuration consists of a cluster of IBM 2145 Model 4F2 servers, called SVC Storage Engines. Each SVC Storage Engine is a node; two nodes make up a node pair (I/O Group), and one to four I/O Groups constitute a SAN Volume Controller cluster. The cluster is scalable from one to four node pairs (I/O Groups) and supported by dual read/write cache. This design is intended to avoid single points of failure and support concurrent maintenance.

IBM TotalStorage SAN Volume Controller Storage Engine

The SVC Storage Engine is shipped with preloaded IBM TotalStorage SAN Volume Controller Storage Software (ordered separately).

The storage engines must be installed in pairs to provide load sharing and failover protection.(1) Four optical fiber cables are required by each engine in the cluster for connection to the Fibre Channel Switches in the SAN. If the Master Console (#4001 or #4002) is included in the initial SVC Storage Engine order, two additional optical fiber cables are required. These cables are not provided as part of the engine but may be ordered by feature number.

Each SVC Storage Engine has an Ethernet port for connection via Ethernet LAN to the master console, which provides configuration and error reporting. These connections need to be aggregated together through an Ethernet hub or switch. The Ethernet hub or switch and cabling are not included as part of the SAN Volume Controller.

Note: (1) The SVC Storage Engine may be installed only in multiples of two, up to a maximum of eight machines per SAN Volume Controller cluster.

Master Console

The master console is used as a platform for all the configuration, management, and service software required to manage the SAN Volume Controller. The hardware feature, #4001, is a rack-mounted server and includes a keyboard and monitor. The master console, monitor, and keyboard (#4001) occupy a 2U space in the rack. Its preloaded software provides the following functions:

  • SNMP Trap management
  • "Call Home" capability
  • "Remote Service" capability via Virtual Private Network (VPN)
  • Browser support for FC switches
  • SAN Volume Controller CLI support for configuration
  • SAN Volume Controller configuration using the SAN Volume Controller Console
  • SAN Topology rendering using Tivoli SAN Manager

The Master Console - Software (#4002) provides the same function, but is a software-only alternative feature and must be installed on equivalent customer-provided hardware. If this feature is selected, a customer-supplied equivalent server with the following characteristics must be provided.

  • Hardware:

    • One Pentium** 4 processor, minimum 2.6 GHz

    • Minimum of 2 GB of system memory

    • Two IDE hard disk drives, minimum 40 GB each

    • CD-ROM and diskette drives

    • Two 1 Gb ports for Ethernet connections (fiber or copper)

    • One 2 Gb Fibre Channel host bus adapter (HBA) port, such as QLogic 2342 (dual port) or QLogic 2340 (single port) FC-2 cards, or equivalent

    • Keyboard, such as the Space Saver NLS keyboard, or equivalent

    • Monitor, such as Netbay 1U Flat Panel Monitor Console kit without keyboard, or equivalent

    • Mouse, or equivalent pointing device

  • Software:

    • Antivirus software (not required, but strongly recommended)

    • Microsoft® Windows® Internet Explorer with the most recent Service Pack

    • Microsoft Windows operating system, one of:
      • Microsoft Windows 2000 Server Edition with Service Pack 4, or higher
      • Microsoft Windows Server 2003 Standard Edition
      • Microsoft Windows Server 2003 Enterprise Edition

The master console includes IBM and non-IBM Licensed Machine Code. Use is subject to the terms of the applicable licenses.

The master console may be ordered either as feature #4001, or as feature #4002 with the first SVC Storage Engine of the IBM TotalStorage SAN Volume Controller. It is required for each SAN containing IBM TotalStorage SAN Volume Controllers. Additional or subsequent SAN Volume Controllers within a SAN can share the master console.

If the master console is used to manage more than two I/O Groups (4 nodes) within a cluster, it must have 2 GB of RAM. Master consoles shipped after October 29, 2004, ship with 2 GB of RAM installed. For master consoles shipped prior to that date, feature #4201 may be ordered to increase the memory to 2 GB.

A power cord to connect the master console (#4001 only) to a standard Power Distribution Unit (PDU) ships standard with the master console. If the master console will not be installed in a rack with a PDU, a country-specific power cord must be ordered with the master console to connect to an alternate power source.

License Information for programs furnished with the master console features (both #4001 and #4002) is shipped with the master console.

Uninterruptible Power Supplies

In the event of a power failure, the UPS can provide temporary power while the contents of the SVC cache and cluster information is written to the internal disk drive in the SVC. The UPS monitors the condition of its battery to enable planned maintenance actions to be performed on a day that is convenient for the customer.

The UPSs provide an independent source of power to each node in the I/O group. They must not be used for any other purpose.

Each UPS in the pair (#8100) requires a 220 V, 15 amp power source and must be protected by its own 15 amp circuit breaker (provided separately). The UPSs of each node pair should be connected to separate circuits to provide added redundancy.

One UPS pair (#8100) supports one or two I/O Groups; a second UPS pair is required for a three or four I/O Group SVC cluster.

Power cords to connect the UPSs to a standard PDU ship standard with the UPSs. In addition, country-specific power cords must be ordered for UPSs so they can be installed in a rack without a PDU.

Accessibility by People with Disabilities

For Hardware Offerings

The following features support use by people with disabilities:

  • Controls and latches operable with one hand and minimal dexterity
  • The keys on the panel are tactilely discernible without activating them

Back to topBack to top
 
Product Positioning

The SAN Volume Controller is a modular implementation of IBM solutions designed to help address the complexities and cost of managing SAN-based storage. The SAN Volume Controller is designed to be added to existing SANs with minimal disruption.
Back to topBack to top
 
Models

Model Summary Matrix

Model Intel Processor Speed Memory Hard Drive
4F2 2-way Prestonia 2.4 GHz 4 GB 36 GB

Customer Setup (CSU)

No.

Devices Supported

The SAN Volume Controller supports connectivity with Intel-based servers running Windows NT, Windows 2000 Advanced Server, Windows 2003 Advanced Server, Linux Red Hat Advanced Server, SUSE Linux SLES 8, Novell Netware, VMware ESX, and with RISC-based servers running AIX, HP-UX, or Sun Solaris operating systems. Many of these servers require the Subsystem Device Driver (SDD) multipathing driver. Storage controllers from IBM and from other disk array vendors are supported. The full interoperability matrix for SAN Volume Controller solution is available at:

http://www.ibm.com/storage/support/2145

Model Conversions

None.
Back to topBack to top
 
Technical Description
TOC Link Physical Specifications TOC Link Operating Environment TOC Link Limitations
TOC Link Hardware Requirements TOC Link Software Requirements

Physical Specifications

SVC Storage Engine

  • Width: 484 mm (19.0 in)
  • Depth: 670 mm (26.3 in)
  • Height: 42 mm (1.7 in)
  • Weight: 10.9 kg (24 lb)

Master Console (#4001)

  • Width: 478 mm (18.8 in)
  • Depth: 425.5 mm (16.7 in)
  • Height: 44 mm (1.7 in)
  • Weight: 8.6 kg (19 lb)

Master Console Keyboard/Display/Drawer

  • Width: 480 mm (18.9 in)
  • Depth: 530 mm (20.8 in)
  • Height: 40 mm (1.67 in)
  • Weight: 13.9 kg (30.5 lb)

UPS (#8100)

  • Width: 440 mm (17.3 in)
  • Depth: 630 mm (24.8 in)
  • Height: 89 mm (3.5 in)
  • Weight: 38.2 kg (84.0 lb)

Note: These dimensions represent a single UPS. Two UPSs are provided by feature number 8100.

To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product specific installation requirements.

Operating Environment

SVC Storage Engine Operating Environment

Temperature

  • Operating:
    • 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0 to 3000 ft)
    • 10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3,000 to 7,000 ft)

  • Powered off: 10 to 43 degrees C (50 to 109 degrees F)

  • Storage: 1 to 60 degrees C (33 to 140 degrees F) at 0 to 2,133 m (0 to 7,000 ft)

  • Shipping: -20 to 60 degrees C (-4 to 140 degrees F) at 0 to 10,668 m (0 to 35,000 ft)

Relative Humidity

  • Operating and Powered off: 8 to 80%
  • Storage: 5 to 80%
  • Shipping: 5 to 100% (including condensation but excluding rain)

Wet Bulb

  • Wet Bulb (operating temp): 23 degrees C
  • Wet Bulb (powered off temp): 27 degrees C
  • Wet Bulb (storage and shipping temp): 29 degrees C

Noise Level

  • 6.2 bels LwAd - when operating in a 2146 system rack

Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.

Master Console (#4001) Operating Environment

The master console uses the IBM xSeries 305 Server, 8673 Model 62X. For Environmental Specifications of this machine, refer to the product announcement which can be found at:

http://www.ibmlink.ibm.com/ibmlink?xu=guest&xh=logon&request=
usa.announcements&parms=Q
 

Choose "Announcements search" then enter the announcement number, 102-274 in "Search by letter number".

Uninterruptible Power Supplies Operating Environment (#8100)

Note: The specifications for the UPS are taken from specifications provided by the manufacturer, PowerWare and presented for reference only. For use in the SAN Volume Controller environment, the UPS has been programmed to shut down outside of the range of 200-240V.

Temperature

  • Operating: 0 to 40 degrees C (32 to 104 degrees F) at 0-2000 m (0-6560 ft)
  • Powered off: 0 to 40 degrees C (32 to 104 degrees F) at 0-2000 m (0-6560 ft)
  • Storage: 0 to 25 degrees C (32 to 77 degrees F) at 0-2000 m (0-6560 ft)
  • Shipping: -25 to 55 degrees C (-13 to 131 degrees F) at 0 - 15,000 m (0 - 49,212 ft)

Relative Humidity

  • Operating and Powered off: 5-95%
  • Storage: 5-95%
  • Shipping: 5-95% (noncondensing)

Wet Bulb

  • Wet Bulb (operating temp): 23 degrees C
  • Wet Bulb (powered off temp): 27 degrees C
  • Wet Bulb (storage and shipping temp): 29 degrees C

Noise Level

  • 5.3 bels LwAd - When operating in a 2146 system rack.

Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.

Limitations

The IBM TotalStorage SAN Volume Controller is designed to support up to 2 petabytes of storage.

The maximum number of SVC Storage Engines supported in a SAN Volume Controller cluster is eight, configured in four I/O groups.

Feature number 4201 may not be ordered for use in any master console (#4001) shipped after October 29, 2004 or that already has 2 GB of memory installed.

The SAN Volume Controller includes a license for the IBM TotalStorage Productivity Center for Fabric V2.2 Bonus Kit. The license for the IBM TotalStorage Productivity Center for Fabric V2.2 Bonus Kit applies to the enterprise acquiring the SAN Volume Controller Storage Software and allows up to 64 switch ports to be managed. Multiple Bonus Kit licenses (including any licenses the enterprise may have for the predecessor to the Bonus Kit, IBM TotalStorage Productivity Center for Fabric V2.2 Bonus Kit) are not cumulative. These 64 ports may be on more than one switch, but every port on a switch selected for entitlement management must count as a port in the "up to" number, unless the entire entitlement (all 64 ports) are allocated to a single switch which has more than 64 ports. When more than 64 switch ports are managed in an enterprise, a separate license for the full IBM Tivoli Storage Area Network Manager product is required.

Additional limitations and configuration guidelines may apply, as documented in the SAN Volume Controller Storage Software README file, furnished publications for this product, and/or as listed under Configuration Requirements and Guidelines at:

http://www.ibm.com/storage/support/2145

Hardware Requirements

UPS - single (#8115) REQUIREMENTS

Each UPS - single (#8115) in the SVC cluster must be provided a single-phase 220 volt, 10 amp, 50 to 60 Hz power source. It is recommended that the UPSs for each node of a node pair be on separate circuits to provide added redundancy in the system structure.

A power cord to connect the UPS (#8115) to a standard PDU ships standard with the UPS.

In addition, a country-specific power cord must be specified by feature number for connection to wall-type outlets should the rack not have a compatible PDU or if the PDU has wall-type outlets. One of the following power cord Specify Features is required to connect the UPS to the alternate power source.

Each power cord feature provides one country-specific power cord. Countries supported by these features include:

  • UPS-8115 Power Cord (#1) (#9714)
    • Provides power cords for U.S., Canada, Mexico, others.
    • Six feet (1.8 m), unshielded, rated 250 V/15 A.
    • Attached plug (NEMA L6-15P) designed for 200-240 V ac input.
    • Part number: 7842122

  • UPS-8115 Power Cord (#2) (#9715)
    • Provides power cords for U.S., Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, N. Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad, Venezuela.
    • Nine feet (2.8 m), unshielded, rated 250 V/15 A.
    • Attached plug (NEMA L6-15P) designed for 200-240 V ac input.
    • Part number: 7842123

  • UPS-8115 Power Cord (#3) (#9716)
    • Provides power cords for Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong S.A.R), Cyprus, Dubai, Figi, Ghana, India, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, UK, Yemen, Zambia.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (BS 1363/A) designed for 200-240 V ac input.
    • Part number: 14F0033

  • UPS-8115 Power Cord (#4) (#9717)
    • Provides power cords for Argentina, Australia, China (PRC), New Zealand, Papua New Guinea, Paraguay, Uruguay, Western Samoa.
    • Nine feet (2. 8 m), unshielded, rated 250 V/10 A.
    • Attached plug (AS/NZS C112) designed for 200-240 V ac input.
    • Part number: 39M5102

  • UPS-8115 Power Cord (#5) (#9718)
    • Provides power cords for Afghanistan, Albania, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungry, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, Zimbabwe.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (CEE 7-VII) designed for 200-240 V ac input.
    • Part number: 13F9979

  • UPS-8115 Power Cord (#6) (#9719)
    • Provides power cords for Denmark.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (DK2-5a) designed for 200-240 V ac input.
    • Part number: 13F9997

  • UPS-8115 Power Cord (#7) (#9720)
    • Provides power cords for Bangladesh, Burma, Pakistan, South Africa, Sri Lanka.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (SABS 164) designed for 200-240 V ac input.
    • Part number: 14F0015

  • UPS-8115 Power Cord (#8) (#9721)
    • Provides power cords for Switzerland, Liechtenstein.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (1011-S2450 7) designed for 200-240 V ac input.
    • Part number: 14F0051

  • UPS-8115 Power Cord (#9) (#9722)
    • Provides power cords for Chile, Ethiopia, Italy, Libya, Somalia.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (CEI 23-16) designed for 200-240 V ac input.
    • Part number: 14F0069

  • UPS-8115 Power Cord (#10) (#9723)
    • Provides power cords for Israel.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (SI 32) designed for 200-240 V ac input.
    • Part number: 14F0087

  • UPS-8115 Power Cord (#11) (#9724)
    • Provides power cords for Thailand.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (NEMA 6-15P) designed for 200-240 V ac input.
    • Part number: 1838574

  • UPS-8115 Power Cord (#12) (#9725)
    • Provides power cords for Argentina.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (IRSM 2073)designed for 200-240 V ac input.
    • Part number: 36L8880

  • UPS-8115 Power Cord (#13) (#9726)
    • Provides power cords for China.
    • Nine feet (2.8 m), unshielded, rated 250 V/6 A.
    • Attached plug (GB 2099.1)designed for 200-240 V ac input.
    • Part number: 02K0546

Power Cords - UPS pair (#8100)

Each UPS in the UPS pair must be powered by a single-phase 220 volt, 15 amp, 50 to 60 Hz power source. It is recommended that these be on separate circuits to provide added redundancy in the system structure. If there are two UPS pairs in the SVC cluster, they may share the two dedicated circuits, but each UPS must still be protected by its own 15 amp circuit breaker.

Power cords to connect the UPSs (feature #8100) to a compatible PDU ships standard with the UPSs.

In addition, country-specific power cords must be specified by feature number for connection to wall-type outlets should the rack not have a compatible PDU or if the PDU has wall-type outlets. One of the following power cord Specify Features is required to connect the UPSs (#8100) to the alternate power source.

Each power cord feature provides two country-specific power cords. Countries covered by these features include:

  • Feature number 9800 - UPS Power Cord - U.S./Canada:

    • Provides power cords for Bahamas, Barbados, Bermuda, Bolivia, Brazil, Cayman Islands, Colombia, Costa Rica, Dominican republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indes), United States, Canada, and Venezuela.

    • 8.125 feet (2.5 m), unshielded, rated 250 V/15 A.

    • Attached plug (NEMA L6-15P) is designed for 200-240 V ac input.

    • Part number: 12J5119

  • Feature number 9820 - UPS Power Cord - Europe, Middle East, Africa:

    • Provides power cords for Afghanistan, Albania, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Republic, Chad, Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guiana, Hungry, Iceland, Indonesia, Iran, Ivory Coast, Israel, Jordan, Lebanon, Luxembourg, Macao, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, Zimbabwe.

    • 8.125 feet (2.5 m), unshielded, rated 250 V/16 A.

    • Attached plug (CEE7) is designed for 200-240 V ac input.

    • Part number: 55H6643

  • Feature number 9825 - UPS Power Cord - Switzerland, Liechtenstein:

    • Provides power cords for Chile, Ethopia, Italy, Libya, Liechtenstein, Somalia, and Switzerland.

    • 8.125 feet (2.5 m), unshielded, rated 250 V/16 A.

    • Attached plug (CEI 23-16) is designed for 200-240 V ac input.

    • Part number: 12J5126

  • Feature number 9827 - UPS Power Cord - Thailand:
    • Provides power cord for Thailand.
    • 8.125 feet (2.5 m), unshielded, rated 250 V/15 A.
    • Attached plug (NEMA 6-15P) is designed for 200-240 V ac input.
    • Part number: 12J5120

  • Feature number 9829 - UPS Power Cord - Pakistan, South Africa:
    • Provides power cords for Bangladesh, Burma, Pakistan, South Africa, Sri Lanka.
    • 8.125 feet (2.5 m), unshielded, rated 250 V/16 A.
    • Attached plug (SABS 164) is designed for 200-240 V ac input.
    • Part number: 12J5124

  • Feature number 9831 - UPS Power Cord - Australia, New Zealand:

    • Provides power cords for Argentina, Australia, China (PRC), New Zealand, Papua New Guinea, Paraguay, Uruguay, Western Samoa.

    • 8.125 feet (2. 8 m), unshielded, rated 250 V/20 A.

    • Attached plug (L6-20P) is designed for 200-240 V ac input.

    • Part number: 12J5118

  • Feature number 9838 - UPS Power Cord - Denmark:

    • Provides power cords for Denmark, Antigua, Bahrain, Brunei, Channel Islands, Cyprus, Dubai, Fiji, Ghana, Hong Kong, India, Iraq, Ireland, Kenya, Kuwait, Malysia, Malawi, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, United Kingdom, Yemen, Zambia.

    • 8.125 feet (2.5 m), unshielded, rated 250 V/16 A.

    • Attached plug (IEC 309) is designed for 200-240 V ac input.

    • Part number: 36L8822

  • Feature number 9986 - UPS Power Cord - U.S./Canada:
    • Provides power cords for United States (Chicago), Canada, Mexico, and others.
    • Six feet (1.8 m), unshielded, rated 250 V/15 A.
    • Attached plug (NEMA L6-15P) is designed for 200-240 V ac input.
    • Part number: 14F1549

Power Cords - Master Console

The master console, if required for the initial SVC Storage Engine, requires one 110 volt power source.

A power cord to connect the master console (feature number 4001) to a standard PDU ships standard with the master console.

If the master console is not be installed in a rack with a PDU, one of the following power cords must be ordered along with the master console (#4001 only) to connect to an alternate power source.

When specified, one (1) power cord ships with the master console.

  • (#9701) MC Power Cord (#1) U.S. Six Feet (1.8 m), 120 V
    • Provides power cords for U.S., Canada, Mexico, others.
    • Six feet (1.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (NEMA 5-15P) designed for 100-120 V ac input.
    • Part number: 6952301

  • (#9702) MC Power Cord (#2) Europe, Middle East, Africa

    • Provides power cords for Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong S.A.R), Cyprus, Dubai, Fiji, Ghana, India, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, UK, Yemen, and Zambia.

    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.

    • Attached plug (BS 1363/A) designed for 200-240 V ac input.

    • Part number: 14F0033

  • (#9703) MC Power Cord (#3) Australia, New Zealand

    • Provides power cords for Argentina, Australia, China (PRC), New Zealand, Papua New Guinea, Paraguay, Uruguay, Western Samoa.

    • Nine feet (2. 8 m), unshielded, rated 250 V/10 A.

    • Attached plug (AS/NZS C112) designed for 200-240 V ac input.

    • Part number: 39M5102

  • (#9704) MC Power Cord (#4) Europe, South Korea

    • Provides power cords for Afghanistan, Albania, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungry, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, and Zimbabwe.

    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.

    • Attached plug (CEE 7-VII) designed for 200-240 V ac input.

    • Part number: 13F9979

  • (#9705) MC Power Cord (#5) Europe, Denmark
    • Provides power cords for Denmark.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (DK2-5a) designed for 200-240 V ac input.
    • Part number: 13F9997

  • (#9706) MC Power Cord (#6) Pakistan, South Africa
    • Provides power cords for Bangladesh, Burma, Pakistan, South Africa, Sri Lanka.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (SABS 164) designed for 200-240 V ac input.
    • Part number: 14F0015

  • (#9707) MC Power Cord (#7) Switzerland, Liechtenstein
    • Provides power cords for Switzerland, Liechtenstein.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (1011-S2450 7) designed for 200-240 V ac input.
    • Part number: 14F0051

  • (#9708) MC Power Cord (#8) Chile, Italy, Ethiopia
    • Provides power cords for Chile, Ethiopia, Italy, Libya, Somalia.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (CEI 23-16) designed for 200-240 V ac input.
    • Part number: 14F0069

  • (#9709) MC Power Cord (#9) Israel
    • Provides power cords for Israel.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (SI 32) designed for 200-240 V ac input.
    • Part number: 14F0087

  • (#9710) MC Power Cord (#10) U.S., Japan, South America - 240 V
    • Provides power cords for Thailand.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (NEMA 6-15P) designed for 200-240 V ac input.
    • Part number: 1838574

  • (#9711) MC Power Cord (#11) Argentina
    • Provides power cords for Argentina.
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A.
    • Attached plug (IRSM 2073)designed for 200-240 V ac input.
    • Part number: 36L8880

  • (#9712) MC Power Cord (#12) China
    • Provides power cords for China.
    • Nine feet (2.8 m), unshielded, rated 250 V/6 A.
    • Attached plug (GB 2099.1)designed for 200-240 V ac input.
    • Part number: 02K0546

  • (#9713) MC Power Cord (#13) US Nine Foot (2.8 m)

    • Provides power cords for U.S., Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman Islands, Colombia, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, Nicaragua, N. Antilles, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad, Venezuela.

    • Nine feet (2.8 m), unshielded, rated 125 V/10 A.

    • Attached plug (NEMA 5-15P) designed for 100-120 V ac input.

Every SAN Volume Controller must be connected via Ethernet to a master console. Multiple clusters can be managed by a single master console. Therefore, at least the first cluster installed in a SAN must include a Master Console (#4001) or the Master Console - Software (#4002) feature.

Fibre Channel and Ethernet cables are not included as part of the hardware provided by IBM. These are the responsibility of the customer. Each SVC Storage Engine requires four fiber optic cables. If a master console is included in the order for the initial SVC Storage Engine, two additional fiber optic cables are required. Fiber optic cables may be optionally ordered with the SVC Storage Engines by feature number.

Master Console - Software (#4002) requirments

This feature requires a customer-supplied server that meets the following characteristics:

  • One Pentium** processor, minimum 2.6 GHz

  • Minimum of 2 GB of system memory

  • Two IDE hard disk drives, minimum 40 GB each

  • CD-ROM and diskette drives

  • Two 1 Gb ports for Ethernet connections (fiber or copper)

  • One 2 Gb Fibre Channel host bus adapter (HBA) port, such as QLogic 2342 (dual port) or QLogic 2340 (single port) FC-2 cards, or equivalent

  • Keyboard, such as the Space Saver NLS keyboard, or equivalent

  • Monitor, such as Netbay 1U Flat Panel Monitor Console kit without keyboard, or equivalent

  • Mouse, or equivalent pointing device

Software Requirements

The SVC Storage Engines require that the SVC Storage Software V2 (5639-VC2) be ordered at the same time the initial order for the engines of a cluster is placed.

The SVC storage software can be ordered via the AAS ordering system or the Passport Advantage system. The appropropriate hardware feature (#0017 for Passport Advantage, #0018 for AAS) must be included in the hardware order for the initial engine to indicate the desired fulfillment system.

For additional details, refer to Software Announcement 205-xxx, dated February 15, 2005.

Master Console - Software (#4002) requirments

This feature requires a customer-supplied server operating with the following software:

  • Antivirus software (not required, but strongly recommended)
  • Microsoft® Windows® Internet Explorer with the most recent Service Pack
  • Microsoft Windows operating system
    • Microsoft Windows 2000 Server Edition with Service Pack 4, or higher
    • Microsoft Windows Server 2003 Standard Edition
    • Microsoft Windows Server 2003 Enterprise Edition

Back to topBack to top
 
Publications

The following publications are shipped with the product. Additional copies are available immediately.

                                                            Form
                        Title                              Number
-----------------------------------------                 ---------
 IBM TotalStorage SAN Volume Controller                   SC26-7541
 Installation Guide  (Hardcopy)
 IBM TotalStorage SAN Volume Controller                   SC26-7542
 Service Guide (Hardcopy)
 IBM TotalStorage SAN Volume Controller                   SC26-7543
 Configuration Guide (Hardcopy)
 IBM TotalStorage SAN Volume Controller                   SC26-7577
 Translated Safety Notices (Hardcopy)
 IBM TotalStorage SAN Volume Controller                   SK2T-8811
 Customer and Service Documentation
  Includes:
   IBM TotalStorage SAN Volume Controller                 SC26-7541
   Installation Guide
   IBM TotalStorage SAN Volume Controller                 SC26-7542
   Service Guide
   IBM TotalStorage SAN Volume Controller                 SC26-7543
   Configuration Guide
   IBM TotalStorage SAN Volume Controller                 SC26-7544
   Command-Line Interface User's Guide
   IBM TotalStorage SAN Volume Controller                 GA22-1052
   Planning Guide
   IBM TotalStorage SAN Volume Controller                 SC26-7545
   CIM Agent Developer's Reference
   IBM TotalStorage SAN Volume Controller                 SC26-7563
   Host Attachment Guide
   IBM TotalStorage Multipath Subsystem                   SC30-4096
   Device Driver User's Guide
 

Back to topBack to top
 
Features -- Specify/Special/Exchange
TOC Link No Charge Specify Codes TOC Link Special Feature Codes -- Chargeable TOC Link Feature Exchanges

No Charge Specify Codes

Feature
Number   Description                             Machine   Model
-------  ------------------------------------    -------   -----
9714     UPS-8115 Power Cord (#1)                 2145      4F2
9715     UPS-8115 Power Cord (#2)                 2145      4F2
9716     UPS-8115 Power Cord (#3)                 2145      4F2
9717     UPS-8115 Power Cord (#4)                 2145      4F2
9718     UPS-8115 Power Cord (#5)                 2145      4F2
9719     UPS-8115 Power Cord (#6)                 2145      4F2
9720     UPS-8115 Power Cord (#7)                 2145      4F2
9721     UPS-8115 Power Cord (#8)                 2145      4F2
9722     UPS-8115 Power Cord (#9)                 2145      4F2
9723     UPS-8115 Power Cord (#10)                2145      4F2
9724     UPS-8115 Power Cord (#11)                2145      4F2
9725     UPS-8115 Power Cord (#12)                2145      4F2
9726     UPS-8115 Power Cord (#13)                2145      4F2

UPS (#8115) Power Cords

One power cord to connect each UPS (feature #8115) to a compatible Power Distribution Unit (PDU), ships standard with the UPS.

In addition, a country-specific power cord must be specified by feature number for connection to wall-type outlets should the rack not have a compatible PDU or if the PDU has wall-type outlets. One of the following power cord Specify Features is required to connect each UPS - single (#8115) to the alternate power source.

Each power cord feature provides one country-specific power cord. Countries supported by these features are listed in the Hardware Requirements section.

Power cords are Plant installable only.

  • Minimum number of features: One.
  • Maximum number of features: One.
  • Prerequisites: Feature #8115.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Only one UPS Power Cord feature may be ordered for each UPS (#8115)
  • Field installable: No.
  • Plant installable: Yes.

UPS (#8100) Power Cords

(No Longer Available as of May 10, 2005)

Power cords to connect the UPS pair(s) (feature number 8100) to a compatible Power Distribution Unit (PDU), ship standard with the UPSs.

In addition, country-specific power cords must be specified by feature number for connection to wall-type outlets should the rack not have a compatible PDU or if the PDU has wall-type outlets. One of the following power cord Specify Features is required to connect each UPS pair to the alternate power source. If two UPS pairs are ordered, two country-specific power cord features must be ordered.

Each power cord feature provides two country-specific power cords. Countries covered by these features are listed in the

Hardware Requirements section.

Power cords are both Plant and Field installable.

(All the following power cords No Longer Available as of May 10, 2005)

Power Cord
Description                       Machine   Model   Feature
-----------------------------     -------   -----   -------
UPS Power Cord - US/Canada         2145      4F2     9800
  (250V/15A - 2.5 m)
UPS Power Cord - EMEA              2145      4F2     9820
  (250V/16A - 2.5 m)
UPS Power Cord - Swiss, Liech      2145      4F2     9825
  (250V/16A - 2.5 m)
UPS Power Cord - Thailand          2145      4F2     9827
  (250V/15A - 2.5 m)
UPS Power Cord - S. Africa         2145      4F2     9829
  (250V/16A - 2.5 m)
UPS Power Cord - Aust/NZ           2145      4F2     9831
  (250V/20A - 2.5 m)
UPS Power Cord - Denmark           2145      4F2     9838
  (250V/16A - 2.5 m)
UPS Power Cord - US/Chicago        2145      4F2     9986
  (250V/15A - 1.8 m)
 
  • Minimum number of features: One.
  • Maximum number of features: Two.
  • Prerequisites: Feature #8100.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Only one UPS Power Cord feature may be ordered for each UPS pair.
  • Field installable: No.
  • Plant installable: Yes.

Master Console power cords

A power cord to connect the master console (feature number 4001) to a standard Power Distribution Unit (PDU) will ship standard with the master console. If the master console will not be installed in a rack with a PDU, a power cord must be ordered with the master console to connect to an alternate power source. If a PDU is not being used one of the following power cord features must be included in the order. The master console, if required for the initial SVC Storage Engine, requires one 110 volt power source. If a PDU is not used, one of the following power cord specify features is required to connect the master console to the power source.

Description                    Machine  Model  Feature
----------------------         -------  -----  -------
MC Power Cord (#1)              2145     4F2    9701
  U.S. 110 V 6'
MC Power Cord (#2)              2145     4F2    9702
  Eur,Mid-East,Africa
MC Power Cord (#3)              2145     4F2    9703
  Austral,N.Z.
MC Power Cord (#4)              2145     4F2    9704
  Eur,S.Korea
MC Power Cord (#5)              2145     4F2    9705
  Eur,Den
MC Power Cord (#6)              2145     4F2    9706
  Pakistan,S.Africa
MC Power Cord (#7)              2145     4F2    9707
  Switz,Liechtenstein
MC Power Cord (#8)              2145     4F2    9708
  Chile,Italy,Ethiopia
MC Power Cord (#9)              2145     4F2    9709
  Israel
MC Power Cord (#10)             2145     4F2    9710
  US/Japan/S.America
MC Power Cord (#11)             2145     4F2    9711
  Argentina
MC Power Cord (#12)             2145     4F2    9712
  China
MC Power Cord (#13)             2145     4F2    9713
  US 110 V, 9'
 
  • Minimum number of features: None.
  • Maximum number of features: Two.
  • Prerequisites: Feature #4001.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Only one MC Power Cord feature may be ordered for each master console (#4001)
  • Field installable: Yes.
  • Plant installable: Yes.

Miscellaneous Features

(#9298) SAN Integration Server

(No Longer Available as of June 22, 2004)

This feature must be specified for every SVC Storage Engine that is ordered as part of an order for the SAN Integration Server (Machine Type 2146). This feature is plant installed only.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: N/A.
  • Limitations: May be specified for 2146 orders only.
  • Field installable: No.
  • Plant installable: Yes.

Special Feature Codes -- Chargeable

                                                        Plant/
Description                    Machine  Model  Feature  Field   CSU(1)
----------------------------   -------  -----  -------  ------  ---
Storage Engine Preload          2145     4F2    0010    Plant   No
Storage Engine Preload PA       2145     4F2    0017    Plant   No
Storage Engine Preload AAS      2145     4F2    0018    Plant   No
Site secondary HW cluster       2145     4F2    0019    Plant   No
Initial Storage Engine          2145     4F2    3001    Plant   No
Additional Storage Engine       2145     4F2    3002    Plant   No
Master Console                  2145     4F2    4001    Both    No
Master Console - Software       2145     4F2    4002    Both    No
Master Console memory u/g       2145     4F2    4201    Field   No
1 m Fiber Optic Cable LC-LC     2145     4F2    5301    Both    No
5 m Fiber Optic Cable LC-LC     2145     4F2    5305    Both    No
25 m Fiber Optic Cable LC-LC    2145     4F2    5325    Both    No
LC-SC FC Adapter Cable          2145     4F2    5702    Both    No
UPSs                            2145     4F2    8100    Plant   No
UPS - Single                    2145     4F2    8115    Plant   No
 

Note: (1) CSU = Customer Setup.

Code Preloads

(#0010) Storage Engine Preload

This feature provides the required SVC Storage Software that will be preloaded by IBM on the SVC Storage Engine. It must be included with each SVC Storage Engine ordered. This feature is plant installed only.

  • Minimum number of features per Model 4F2: One.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: No.
  • Plant installable: Yes.

(#0017) Storage Engine Preload PA

This feature specifies that the software order be fulfilled via Passport Advantage. This feature must be included in the order for the first SVC Storage Engine ordered for a cluster (#3001), unless the software order is to be fulfilled via AAS (#0018). This feature is plant installed only and is mutually exclusive with feature number 0018.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: Feature #3001.
  • Corequisites: Feature #0010.
  • Compatibility Conflicts: Mutually exclusive with #0018.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: No.
  • Plant installable: Yes.

(#0018) Storage Engine Preload AAS

This feature specifies that the software order be fulfilled via AAS. This feature must be included in the order for the first SVC Storage Engine ordered for a cluster (#3001), unless the software order is to be fulfilled via Passport Advantage (#0017). This feature is plant installed only and is mutually exclusive with feature number 0017.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: Feature #3001.
  • Corequisites: Feature #0010.
  • Compatibility Conflicts: Mutually exclusive with #0017.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: No.
  • Plant installable: Yes.

(#0019) Site secondary HW cluster

This feature is for administrative purposes only and specifies that the order for a new cluster is not for the first cluster to be installed at the customer site; it specifies that this is for a subsequent cluster to be installed at the same site. Specifying feature #0019 will verify that no software is to be ordered, that is, that a software license is already in effect for a SVC cluster installed at the customer site.

  • Minimum number of features per Model 4F2: None.

  • Maximum number of features per Model 4F2: One.

  • Maximum number of features per Model 4F2: None,if first cluster installed at site.

  • Prerequisites: Feature #3001.

  • Corequisites: None.

  • Compatibility Conflicts: Mutually exclusive with #3002.

  • Customer Setup: No.

  • Limitations: None.

  • Field installable: No.

  • Plant installable: Yes.

Engine Features

(#3001) Initial Storage Engine

Feature number 3001 is used to indicate the first SVC Storage Engine of a SAN Volume Controller cluster. It must be included for one, and only one, SVC Storage Engine in a new cluster order. An order for the SVC Storage Software (5639-VC2) must be placed when feature number 3001 is ordered. This feature also provides the publications and software CD-ROMs included with the first SVC Storage Engine in the cluster. This feature is plant installed only.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: None.
  • Corequisites: Feature #0010 and either #0017 or #0018.
  • Corequisites: Feature #8100.
  • Compatibility Conflicts: Mutually exclusive with Feature 3002.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: No.
  • Plant installable: Yes.

(#3002) Additional Storage Engine

Feature number 3002 is used to indicate all additional SVC Storage Engines of a SAN Volume Controller cluster and for all SVC Storage Engines to be added to an existing (already installed) SAN Volume Controller cluster. When ordered as part of a new cluster, the number must be an odd number (1, 3, 5, or 7); when ordered to add to an existing cluster, the number must be even (2, 4, or 6). This feature is plant installed only.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: None.
  • Corequisites: Feature #0010.
  • Compatibility Conflicts: Mutually exclusive with Feature 3001.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: No.
  • Plant installable: Yes.

(#4001) Master Console

Feature number 4001 provides the master console for a SAN Volume Controller. The Master Console (# 4001) is an optional feature but must be included in an order for the initial (first) SVC Storage Engine of the first SAN Volume Controller cluster installed in a SAN. A SAN may have multiple SAN Volume Controller clusters installed and "managed" by just one master console.

This feature includes IBM and non-IBM Licensed Machine Code. Use is subject to the terms of the applicable licenses.

If the master console is used to manage more than two I/O Groups (4 nodes) within a cluster, it must have 2 GB of RAM. Master consoles shipped after October 29, 2004 ship with 2 GB of RAM installed. Questions about master console memory requirements should be directed to: Virtualization One-Off Administrator/Raleigh/IBM@IBMUS by your IBM sales representative.

Each master console includes a power (line) cord that will connect the master console to a rack PDU. An optional country-specific power cord, specified by feature number, may also be ordered with the initial SVC Storage Engine order if a PDU is not used.

This feature is both plant and field installable.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Two; features #4001 and #4002, in any combination, may not exceed a quantity of two.
  • Prerequisites: Feature number 3001 for orders of new clusters. None for MES orders.
  • Corequisites: None.
  • Compatibility Conflicts: Mutually exclusive with feature #3002.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

(#4002) Master Console - Software

This feature provides the master console software CD kit. If the master console, #4001, is not to be installed with the SVC cluster, a customer-supplied equivalent server must be substituted. This feature provides the software to manage the cluster; it is the equivalent of the software preloaded on feature #4001.

Fiber optic cables are required to connect the master console to the cluster.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Two; features #4001 and #4002, in any combination, may not exceed a quantity of two.
  • Prerequisites: Feature number 3001 for orders of new clusters. None for MES orders.
  • Corequisites: None.
  • Compatibility Conflicts: Mutually exclusive with feature #3002.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

(#4201) Master Console memory u/g

This feature provides an additional 1 GB memory for a currently installed master console that was shipped prior to October 29, 2004. It is required only if the master console will manage a SAN Volume Controller cluster of more than four nodes (engines).

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: No.

Cables

(#5301) 1 m Fiber Optic Cable LC-LC

This feature provides one 1-meter, fiber optic cable with LC connectors on each end. Four of this feature may be ordered with each SVC Storage Engine If feature number 4001 (master console) is included in the order for the SVC Storage Engine, the maximum number that may be ordered is six. This feature is both plant and field installable.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Four if # 4001 (master console) is not included in the order.
  • Maximum number of features per Model 4F2: Six if # 4001 (master console) is included in the order.
  • Maximum number of features per Model 4F2: Eight if two master console features (#4001) are included in the order.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

(#5305) 5 m Fiber Optic Cable LC-LC

This feature provides one 5-meter, fiber optic cable with LC connectors on each end. Four of this feature may be ordered with each SVC Storage Engine. If feature number 4001 (master console) is included in the order for the SVC Storage Engine, the maximum number that may be ordered is six. This feature is both plant and field installable.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Four if # 4001 (master console) is not included in the order.
  • Maximum number of features per Model 4F2: Six if # 4001 (master console) is included in the order.
  • Maximum number of features per Model 4F2: Eight if two master console features (#4001) are included in the order.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

(#5325) 25 m Fiber Optic Cable LC-LC

This feature provides one 25-meter, fiber optic cable with LC connectors on each end. Four of this feature may be ordered with each SVC Storage Engine. If feature number 4001 (master console) is included in the order for the SVC Storage Engine, the maximum number that may be ordered is six. This feature is both plant and field installable.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Four if # 4001 (master console) is not included in the order.
  • Maximum number of features per Model 4F2: Six if # 4001 (master console) is included in the order.
  • Maximum number of features per Model 4F2: Eight if two master console features (#4001) are included in the order.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

(#5702) LC-SC FC Adapter Cable

Feature number 5702 provides an adapter that allows an LC connector to be connected to an SC port. Four of this feature may be ordered with each SVC Storage Engine. If feature number 4001 (master console) is included in the order for the SVC Storage Engine, the maximum number that may be ordered is six. This feature is both plant and field installable.

  • Minimum number of features per Model 4F2: None.
  • Maximum number of features per Model 4F2: Four if # 4001 (master console) is not included in the order.
  • Maximum number of features per Model 4F2: Six if # 4001 (master console) is included in the order.
  • Maximum number of features per Model 4F2: Eight if two master console features (#4001) are included in the order.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field installable: Yes.
  • Plant installable: Yes.

UPS

(#8100) Uninteruptible Power Supplies

(No Longer Available as of May 10, 2005)

Feature number 8100 provides dual UPSs for the SAN Volume Controller. One UPS pair supports one or two I/O Groups; a second UPS pair supports a third or fourth I/O Group in a SVC cluster.

Each UPS pair includes power (line) cords that will connect the UPS pair to a rack power distribution unit (PDU). Country-specific power cords, specified by feature number, must also be included in the order for each UPS pair ordered.

  • Minimum number of features per Model 4F2: One on the initial order; none on a subsequent order.
  • Maximum number of features per Model 4F2: Two on the initial order; one on a subsequent order.
  • Prerequisites: Feature #3001 on the initial order. Feature #3002 on subsequent orders for the cluster.
  • Corequisites: One country-specific power cord (#98xx).
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Maximum of two #8100 per SVC cluster.
  • Field installable: No.
  • Plant installable: Yes.

(#8115) UPS - Single

This feature provides one UPS for one engine (node) of the SAN Volume Controller cluster. (Feature number 8100 provided a pair of UPSs, each of which supported two engines.) UPS - single (#8115) requires SVC Storage Software V2, or later.

For new SVC clusters ordered after May 10, 2005 which will run with SVC software V2, or later, feature number 8100 may not be ordered; one UPS - single must be ordered for each engine of a SVC cluster, both for the initial engine (#3001) and for additional engines (#3002).

Feature numbers 8115 and 8100 may be mixed in a SVC cluster only if SVC Storage Software V2, or later, is installed on the cluster.

Each UPS includes a power (line) cord for connecting the UPS to a rack PDU. Country-specific power cords, specified by feature number, must also be ordered when each UPS is ordered.

This feature is plant installed only.

  • Minimum number of features per Model 4F2: None.(1)
  • Maximum number of features per Model 4F2: One.
  • Prerequisites: Feature #3001 or #3002.
  • Corequisites: One country-specific power cord (#9714-#9726).
  • Compatibility Conflicts: Mutually exclusive with #8100.
  • Customer Setup: No.
  • Limitations: Maximum of eight per SVC cluster. Not supported by SVC Storage Software V1.x.
  • Field installable: No.
  • Plant installable: Yes.

Note: (1) For new SVC clusters using SVC Storage Software V2, or later, the minimum is one. For existing clusters using SVC Storage Software V1, and upgrading with additional nodes, the minimum is none.

Feature Exchanges

Not available.
Back to topBack to top
 
Accessories

None.

Customer Replacement Parts

None.
Back to topBack to top
 
Machine Elements

None.
Back to topBack to top
 
Supplies

None.

Diskettes

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Windows is a trademark of Microsoft Corporation.
 © IBM Corporation 2005.
Back to topBack to top