The IBM 2109 TotalStorage SAN 256B director:
- Is designed to deliver next generation enterprise director
performance, scalability, flexibility, reliability, and availability
- Is designed to provide a single domain with 256-port Fabric Switch
functionality, yielding greater scalability with fewer domains, faster
Control Processor Blades for low latency Fabric OS services, as well as
improved performance over the IBM TotalStorage SAN Switch M14
- Offers forward and backward compatibility with all IBM TotalStorage
SAN Switch models, 1, 2 and 4 Gbps auto-sensing capability, as well as
Advanced Fabric Services and management tools
Designed for mid-range to enterprise level SAN applications, the
SAN256B director includes a minimum of two control processors, dual power
supplies, and fans in a 14U rack height. The SAN256B director base model
includes the following functions:
- Full Fabric operation and Universal Port operation on all ports
(F_Port, FL_Port, and E_Port). Requires ordering at least one of the
optional blades listed below. IBM recommends deployment of at least two
blades per director to enable high availability configurations.
- Inter Switch Link (ISL) Trunking, Advanced Zoning.
- Web tools, Fabric Watch, Performance Monitor.
- Fabric OS 5.0, Hot Code Activation.
Several optional features are available for the director, including
the following:
- M48 32-Port 4 Gbps Switch Blades
- M48 16-Port 4 Gbps Switch Blades
- 4 Gbps short wave transceivers
- 2 Gbps long wave transceivers
- Extended Fabric Activation feature to increase ISL buffer credits to
support disaster tolerance solutions with up to 70 km distance between
sites
- Advanced Security Activation to enable policy-based security
mechanisms integrated within Fabric Operating System
- FICON operation with CUP and optional Advanced Security
- Optional features for director installation into 2109-C36 Cabinet
IBM TotalStorage SAN256B director (2109-M48)
The IBM TotalStorage SAN256B director is designed to support up to
eight, 32-port Fibre Channel switch blades enabling a single domain
director with up to 256 universal (E, F, and FL), full duplex,
auto-sensing ports in a single 14U enclosure. Each port is capable of
self-negotiation to the highest speed supported by the attached SAN
infrastructure, operating at either 1, 2 or 4 Gbps throughput. Distances
up to 10 km, 35 km, or 80 km are supported using the appropriate optional
long wave laser 2 Gbps transceivers and 9.0u fiber cables. Short wave
laser transceivers support distances up to 500m at 1 Gbps and up to 300m
at 2 Gbps or 150m at 4 Gbps with 50.0u fiber cables.
The SAN256B director is designed to provide high availability features
including:
- Full Fabric operation and Universal Port operation on all M48 ports
(F_Port, FL_Port, and E_Port)
- Dual-redundant control processors (active/standby) designed to
provide automatic control processor failover
- Many non-disruptive software upgrades
- Hot-swappable switch blades
- Hot-swappable power supplies in redundant power subsystem
- Hot-swappable blowers in redundant cooling subsystem
- Extensive diagnostics, and system monitoring capabilities integrated
with Fabric OS management tools
- Fabric Shortest Path First (FSPF) rerouting around failed links
Optional Features
The IBM TotalStorage SAN256B director is available with a number of
selectable options. The base SAN256B director does not include switch
blades which are available in either 32-or 16-port configurations. At
least one switch blade is required for host and storage connectivity.
The SAN256B may be configured by adding up to eight 32-port (#3432) or
16-port (#3416) switch blades and a mixture of short wave and long wave
optical transceivers up to the maximum 256 ports.
The SAN256B director will require fiber optic cables for connection to
the host systems, and storage systems or devices. These cables can be
supplied by the customer, or ordered with the switch.
Additional features for the SAN256B director include:
- 4 Gbps short wave SFP transceiver four pack (#2414) - provides four
short wave optical transceiver for SFP LC media.
- 10 km 2 Gb LW SFP transceiver (#2320) - provides 10 km capable long
wave 2 Gb optical transceiver for SFP 9 micron LC media.
- 10 km 2 Gb LW SFP transceiver four pack (#2324) - provides four 10 km
capable long wave 2 Gb optical transceiver for SFP 9 micron LC media.
- 35 km Extended Distance LW SFP Transceiver (#2335) - provides
extended distance long wave optical transceiver for SFP 9 micron LC
media.
- 80 km Extended Distance LW SFP Transceiver (#2380) - provides
extended distance long wave optical transceiver for SFP 9 micron LC
media.
- M48 32-port 4 Gbps Switch Blade (#3432) - provides one 4 Gbps,
32-port switch blade
- M48 16-port 4 Gbps Switch Blade (#3416) - provides one 4 Gbps,
16-port switch blade.
- M48 Remote Switch Activation (#7802) - provides license key to enable
the interconnection of two SAN Switches with a pair of CNT's Open System
Gateways across an asynchronous transfer mode (ATM) wide area network.
- M48 Extended Fabric Activation (#7803) - provides license key that
helps optimize the management of the internal switch buffers to maintain
performance on Inter-Switch Links (ISL) at distances greater than 10 km,
and up to 70 km, utilizing selected fiber cable extension mechanisms
- M48 Advanced Security Activation (#7823) - enables policy-based
security mechanisms integrated within Fabric Operating System Versions
2.6, 3.1, 4.1 and 5.0. To enable Advanced Security capabilities, all
switches within the IBM SAN Switches Fabric must be configured with their
respective Fabric OS version (2.6, 3.1, 4.1 and 5.0) before activating
the Advanced Security optional feature license key. When activated
across the IBM SAN Switch Fabric, the Advanced Security Activation
feature is designed to provide the following comprehensive security
capabilities:
- Centralized security management (trusted switches)
- Fabric-wide security policies to control access
- Port-level access control
- Switch level access control
- Management access controls (Telnet, SNMP, HTTP, API)
- Encryption of management data such as passwords
- Strong and non-reputable authentication between switches
- M48 FICON with CUP activation (#7831) - provides IBM eServer zSeries
FICON support
- M48 FICON with CUP activation and Advanced Security Bundle (#7832) -
provides both IBM eServer zSeries FICON support (#7831) and Advanced
Security (#7823) in one bundle
- First M48 installed in 2109-C36 (#9241) - provides installation of
first 2109-M48 in 2109-C36.
- Second M48 installed in 2109-C36 (#9242) - provides installation of a
second 2109-M48 in 2109-C36.
- Field Merge M48 in 2109-C36 (#9243) - provides plant hardware for
installing 2109-M48 in existing customer 2109-C36
Supported Servers and Storage Systems
The IBM TotalStorage SAN Switch M48 is designed to support Fibre
Channel connectivity for the following:
Servers:
- IBM eServer zSeries and selected S/390 servers
- IBM eServer pSeries and selected RS/6000 servers
- IBM eServer iSeries and selected AS/400 servers
- IBM eServer xSeries and selected Netfinity servers
- Other Intel-based servers with Linux, and Microsoft Windows 2000 and
Windows 2003
- Selected Sun and HP servers
Storage Systems:
- IBM TotalStorage DS8000
- IBM TotalStorage DS6000
- IBM TotalStorage DS4000
- IBM TotalStorage Enterprise Storage Server
- IBM TotalStorage FAStT Family of Storage Servers
- IBM TotalStorage 3580, 3588, 3590, and 3592 Tape Drives
- IBM TotalStorage 3494, 3582, 3583, and 3584 Tape Libraries
- IBM TotalStorage 3581 Tape Autoloader
- IBM TotalStorage 3584 High Availability Frame Model HA1
- Other selected storage systems
For specific support dates, configuration options, server models,
operating systems levels, attachment capabilities, and throughput
connectivity speeds, visit:
- http://www.ibm.com/totalstorage/san/b-type
Back to top
Model
|
Model Summary Matrix
Model |
FC Ports |
Transceivers |
M48 |
0-256 |
0-256 |
Customer Setup (CSU)
No.
Devices Supported
Specific details on supported devices; storage products attachability,
SAN connectivity products, and configuration options are available on the
Web at:
- http://www.ibm.com/totalstorage/san/b-type
Model Conversions
None.
Back to top
Technical Description
|
The IBM TotalStorage SAN256B director is designed to support up to
eight, sixteen-port or thirty two-port Fibre Channel switch blades
enabling a single domain core fabric switch with 256 universal (E, F, and
FL), full duplex, auto-sensing ports in a single 14U enclosure. Each
port is capable of self-negotiation to the highest speed supported by the
attached SAN infrastructure, operating at either 1, 2, or 4 Gbps
throughput. Distances up to 10 km, 35 Km, or 80 Km are supported using
the appropriate optional long wave laser transceiver and 9.0u fiber
cables. Short wave laser transceivers support distances up to 500m at 1
Gb or up to 300m at 2 Gbps or 150m at 4 Gbps with 50.0u fiber cables.
The SAN256B director is designed to provide high availability features
including:
- Dual-redundant control processors (active/standby) designed to
provide automatic control processor fail over
- Many non-disruptive software upgrades
- Hot-swappable switch blades
- Hot-swappable power supplies in redundant power subsystem
- Hot-swappable blowers in redundant cooling subsystem
- Extensive diagnostics, and system monitoring capabilities integrated
with Fabric OS management tools
- Fabric Shortest Path First (FSPF) rerouting around failed links.
The SAN256B director base model includes a minimum of zero switch
blades, zero fiber optic transceivers, two control processors, dual power
supplies, and fans in 14U rack height. Customers will need to order
either the 32-Port or 16-Port 4 Gbps M48 switch blades. Functionality in
the SAN256B director base model includes the following:
- Full Fabric operation and Universal Port operation on all M48 ports
(F_Port, FL_Port, and E_Port)
- Inter Switch Link (ISL) Trunking, Advanced Zoning
- Web tools, Fabric Watch, Performance Monitor
- Fabric OS 5.0, Hot Code Activation
The IBM TotalStorage SAN256B is only available for installation in the
IBM TotalStorage SAN Switch Cabinet C36.
2109-M48 (14U):
- Width: 43.74 cm (17.22 in)
- Height: 61.24 cm (24.11 in)
- Depth (without door): 70.90 cm (27.90 in.)
- Depth (with door): 74.20 cm (29.20 in)
- Weight (without media): 95 to 98 kg (210 to 216 lb)
- Weight (empty chassis): 47 kg (104 lbs)
2109-C36 (36U):
- Height: 1804 mm (71.0 in)
- Width (with side panels): 644 mm (25.4 in)
- Depth (with front/rear doors): 1098 mm (43.3 in)
- Weight (2 M48s): 816 kg (1795 lb)
IBM TotalStorage SAN256B (2109-M48)
- Temperature:
- Ambient Operating: 0 to 40.0 degrees C
- Non-operating: -40 to 70 degrees C
- Humidity Ambient Operating:
- 20% to 85% non-condensing at 40 C
- Non-operating and storage (non-condensing): 10% to 93%
- Altitude Operating: 0 to 3 km
- Shock Operating: 20 G, 11 ms, half sine 1G p-p, 5-500Hz, 1
octave/min
- Shock Non-operating: 33 G, 11 ms, half sine 2.4G p-p, 5-500Hz, 1
octave/min
- Vibration Operating: 5G p-p, 0 to 3kHz at 1.0 octave min
- Vibration Non-operating: 10G p-p, 0 to 5 kHz at 1.0 octave min
- Power: a maximum of 1500 Volt-Amps, 6.4 amps at 240V AC line voltage
or 7.2 amps at 208V AC line voltage.
EMC Conformance:
- ICES 003 Class A
- FCC Part 15 Class A
- VCCI Class A ITE
- EN55022 Class A
- EN55024
- AS NZS 3548 Class A
- CISPR22 Class A
Product Safety/Country Testing/Certification:
- CSA 60950 (Canada)
- UL Standard 60950
- IEC EN60950 (CF-Europe)
- EN60950 (Germany)
- TUV, NEMKO
- Argentina IRAM
- Korea RRL
- Russian Federation GOST GOST
Due to the FCC Classification A and the acoustic sound rating for the
IBM TotalStorage SAN256B (2109-M48), this product should not be installed
in attended rooms. The SAN256B is used only in a typical commercial /
industrial environment and not in a clean room.
The IBM TotalStorage SAN256B is supported only in the IBM TotalStorage
SAN Switch Cabinet C36 (2109-C36).
Specific details on supported operating systems, servers, and devices,
storage products attachability, SAN connectivity products, and
configuration options are available at:
- http://www.ibm.com/totalstorage/san/b-type
Specific details on supported operating system releases are available
at:
- http://www.ibm.com/totalstorage/san/b-type
Back to top
Publications
|
The following publications are shipped with the product.
Additional copies of individual publications are available on the
Internet at:
- http://www.ibm.com/totalstorage/san/b-type
Order
Title Number
------------------------------------------ ---------
IBM TotalStorage SAN256B Installation, GC26-7761
Service, and User's Guide
IBM TotalStorage SAN Cabinet Model C36 GC26-7632
Installation and Service Guide
IBM eServer Translated Safety Notices G229-9054
IBM TotalStorage SAN b-type 2109 Statement GC26-7743
of Limited Warranty
Back to top
Features -- Specify/Special/Exchange
|
IBM TotalStorage SAN256B
Description Machine Model Feature
--------------------------------- ------- ----- -------
IBM TotalStorage SAN256B 2109 M48
First M48 Installed in 2109-C36 9241 (IPO)
Second M48 Installed in 2109-C36 9242 (IPO)
Field Install M48 in 2109-C36 9243 (IPO)
Installation
Summary: The M48 is supported only in the IBM TotalStorage SAN Switch
Cabinet C36 (2109-C36). You must specify in your Initial Plant Order if
one or two SAN256B directors will be plant installed in the 2109-C36.
The only configuration supported in the C36 Cabinet is one or two SAN256B
directors.
(#9241) First M48 Installed in the 2109-C36
Summary: This feature specifies that this is the first SAN256B to be
installed into the C36 Cabinet during manufacture. This M48 will be
located in the lower portion of the cabinet
(#9242) Second M48 Installed in the 2109-C36
Summary: This feature specifies that this is the second SAN256B to be
installed into the C36 Cabinet during manufacture. This M48 will be
located in the upper portion of the cabinet.
When specifying either feature #9241 or #9242 on your initial order,
you must also indicate the corresponding quantity of SAN256B directors
(maximum is two) to be installed in the C36 Cabinet by specifying
2109-C36 feature #9240. The C36 Cabinet along with one or two SAN256B
directors must be grouped on the same system order.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: 2109-C36 with #9240.
- Compatibility Conflicts: #9242 and #9243 can not coexist.
- Compatibility Conflicts: Must specify either #9241, #9242 or #9243
on each SAN256B director initial order.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes.
- Field Installable: No, Initial Plant Order Only.
- Cable Order: None.
(#9243) Field Install M48 in 2109-C36
Summary: This feature indicates that a 2109-C36 Cabinet already
exists at the customer's location, and the M48 being ordered will be the
second SAN256B director installed in the C36 Cabinet. There must be 14U
of contiguous space available in the cabinet to allow field installation
of the M48 SAN256B director.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: A 2109-C36 Cabinet must already exist in the
customer's location to order a new M48 with #9243.
- Corequisites: Existing C36 Cabinet.
- Compatibility Conflicts: #9242 and #9243 can not coexist.
- Compatibility Conflicts: Must specify either #9241, #9242 or #9243
on each SAN256B director initial order. Can coexist with a 2109-M14 in
the same cabinet.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes, available only on new M48 orders.
- Field Installable: No, initial plant orders only
- Cable Order: None.
IBM TotalStorage SAN256B
Description Machine Model Feature
--------------------------------- ------- ----- -------
IBM TotalStorage SAN256B 2109 M48
- 10 Km 2 Gbps LW SPF Transceiver 2320
- 10 Km 2 Gbps LW SFP Transceiver - 4-Pack 2324
- 35 Km 2 Gbps Ext Dist LW SFP Transceiver 2335
- 80 Km 2 Gbps Ext Dist LW SFP Transceiver 2380
- 4 Gbps SW SFP Transceiver 4-Pack 2414
- M48 16-Port 4 Gbps Switch Blade 3416
- M48 32-port 4 Gbps Switch Blade 3432
- M14/M48 N_Port ID Virtualization 4745
- Fiber Cable LC/LC 1m multimode 5301
- Fiber Cable LC/LC 5m multimode 5305
- Fiber Cable LC/LC 25m multimode 5325
- SC/LC Coupling Cable 5371
- LC/SC Coupling Cable 2m 5372
- 9 Micron Fibre Cable 31m, singlemode SC/LC 5730
- 9 Micron Fibre Cable 31m, singlemode LC/LC 5731
- 9 Micron Fibre Cable 2m, singlemode SC/LC 5732
- M48 Remote Switch Activation 7802
- M48 Extended Fabric Activation 7803
- M48 Advanced Security Activation 7823
- M48 FICON w/CUP Activation 7831
- M48 FICON w/CUP, Advanced Security 7833
SAN256B Configuration Options
The SAN256B may be configured by adding up to eight 32-port (#3432) or
16-port (#3416) switch blades and a mixture of short wave and long wave
optical transceivers up to the maximum 256 ports.
Transceivers - Small Form-Factor Pluggable (SFP)
Summary: A minimum of sixteen SFPs are required for each 16-Port
switch blade (#3416), or thirty-two SFPs for each 32-Port switch blade
(#3432) ordered for the SAN256B director.
A mixture of short wave, long wave, or extended distance ports can be
configured by adding up to a maximum of 256 optical transceivers. All
available ports must be populated with SFPs.
(#2320) 2 Gbps Long wave SFP Transceiver
Summary: This feature provides one long wave SFP transceiver,
designed to provide Fibre Channel connections at distances up to 10 Km
(6.2 miles), while using the appropriate 9.0/125 micrometer single mode
fiber optic cable.
(#2335) 35 Km Extended Distance 2 Gbps LW SFP Transceiver
Summary: This optional feature provides a Small Form factor Pluggable
(SFP) fiber optic transceiver, designed for operation with single mode 9
micron fiber optic cables having distances up to 35 Km. The 35 Km
Extended Distance Long wave (LW) SFP Transceiver is designed for full
compatibility with the SAN256B director and can help support disaster
tolerance solutions without the need for separate gateway integration.
(#2380) 80 Km Extended Distance 2 Gbps LW SFP Transceiver
Summary: This optional feature provides a Small Form factor Pluggable
(SFP) fiber optic transceiver, designed for operation with single mode 9
micron fiber optic cables having distances up to 80 Km. The 80 Km
Extended Distance Long wave (LW) SFP Transceiver is designed for full
compatibility with the SAN256B director and can help support disaster
tolerance solutions without the need for separate gateway integration.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: 255.
- Prerequisites: None.
- Corequisites: All available ports must be populated with SFPs
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max totals of features #2320, #2335, and #2380.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Transceivers - SFP 4-Packs
(#2324) 2 Gbps LW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four long wave SFP
transceivers, designed to provide 4 Gbps Fibre Channel connections at
distances up to 10 Km (6.2 miles), while using the appropriate 9.0/125
micrometer single mode fiber optic cable.
(#2414) 4 Gbps SW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four short wave SFP
transceivers, designed to provide Fibre Channel connections at distances
up to 150 meters while using the appropriate 50.0/125 micrometer fiber
optic cable, and distances up to 70 meters while using the appropriate
62.5/125 micrometer fiber optic cable.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: 64.
- Prerequisites: None.
- Corequisites: All available ports must be populated with SFPs.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Min and Max are totals of features #2324, #2414.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
The total of Fiber Optic Transceiver features = (4 x #2414) + #2320 +
(4 x #2324) + #2335 + #2380, and must be a minimum equal to
the number of ports available with switch blades (#3416, and #3432), up
to a maximum of 256.
Switch Blades
Summary: No switch blades are shipped on initial SAN256B orders
unless selected. The base SAN256B director does not include switch
blades which are available in either 32-or 16-port configurations.
Requires ordering at least one of the optional blades listed below. IBM
recommends deployment of at least two blades per director to enable high
availability configurations.
The SAN256B may be configured by adding up to eight 32-port (#3432) or
16-port (#3416) switch blades and a mixture of short wave and long wave
optical transceivers up to the maximum 256 ports.
(#3416) M48 16-Port 4 Gbps Switch Blade
Summary: This feature provides a 16-port 4 Gbps switch blade for the
SAN256B.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: Eight.
- Prerequisites: None.
- Corequisites: All available (16) ports must be populated with SFPs
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Min and Max are totals of features #3416 and #3432.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#3432) M48 32-Port 4 Gbps Switch Blade
Summary: This feature provides a 32-port 4 Gbps switch blade for the
SAN256B.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: Eight.
- Prerequisites: None.
- Corequisites: All available (32) ports must be populated with SFPs
- Compatibility Conflicts: None.
- Customer Set-up: No.
- Limitations: Min and Max are totals of features #3416 and #3432.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#4745) M14/M48 N_Port ID Virtualization:
Summary: Activates N_Port ID Virtualization on the IBM TotalStorage
SAN256B director. Requires Fabric OS V5, or higher.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: Requires Fabric OS Version 5 or higher
- Corequisites: None
- Compatibility Conflicts: None
- Customer Setup: Yes
- Limitations: None
- Field Installable: Yes, both IPO and MES.
Fiber Optic Cables: Summary: A fiber optic cable is
required for attaching the SAN256B to the host system adapters, or other
storage area Fibre Channel components. The cable can be customer
supplied, or ordered with the 2109-M48 in the lengths available. The
attaching fiber cable must be 50.0/125 micrometers for distances up to
300 meters at 2 Gbps speed or 150 meters at 4 Gbps. The attaching fibre
cable must be 62.5/125 micrometers for distances up to 175 meters at 2
Gbps speed or 70 meters at 4 Gbps. The connection is a LC connector
type.
The maximum number of features allowed per SAN256B director is the
total of #5301, #5305, and #5325.
(#5301) Fiber Cable LC/LC 1m multimode
(#5305) Fiber Cable LC/LC 5m multimode
(#5325) Fiber Cable LC/LC 25m multimode
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: 255.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of #5301, #5305, and #5325
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5371) SC/LC Coupling Cable
(#5372) LC/SC Coupling Cable 2m
The maximum number of features allowed per SAN256B director is the
total of #5371, and #5372.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: 255.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of #5371, and #5372
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5730) 9 Micron Fibre Cable 31m, singlemode SC/LC
(#5731) 9 Micron Fibre Cable 31m, singlemode LC/LC
(#5732) 9 Micron Fibre Cable 2m, singlemode SC/LC
The maximum number of features allowed per SAN256B director is the
total of #5730, #5731, and #5732.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: 255.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of #5730, #5731, #5732.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
In many situations, the lengths and installation of fiber optic cables
required will be unique to each customer's configuration and facility
specifications. Product support services offered by IBM Global Services'
Site and Connectivity Solutions can provide assistance for these unique
cabling and installation requirements.
Advanced Functions
(#7802) M48 Remote Switch Activation
Summary: This feature provides a means to obtain the unique
activation key necessary to enable the Remote Switch capability within
the SAN256B director firmware. Remote Switch function is used on two SAN
switches that are interconnected with a pair of CNT's Open System
Gateways, providing the fibre channel to asynchronous transfer mode (ATM)
conversion, across a wide-area network.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Only two IBM SAN b-type switches can be in a fabric
with Remote Switch enabled.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7803) M48 Extended Fabric Activation
Summary: This feature provides a means to obtain the unique
activation key necessary to enable the Extended Fabric capability within
the SAN256B director firmware. Extended Fabric function provides
extensions within the internal switch buffers to maintain performance
with distances greater than ten kilometers, and up to eighty kilometers,
by maximizing buffering between the selected switch interconnect links.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7823) M48 Advanced Security Activation
Summary: The IBM TotalStorage SAN Switch Advanced Security Activation
optional feature enables policy-based security mechanisms integrated
within Fabric Operating System Versions 2.6, 3.1, 4.1, and 5.0. To enable
Advanced Security capabilities, all switches within the IBM SAN Switches
Fabric must be configured with their respective Fabric OS version (2.6,
3.1, 4.1, and 5.0) before activating the Advanced Security optional
feature license key. When activated across the IBM SAN Switch Fabric,
the Advanced Security Activation feature is designed to provide the
following security capabilities.
- Centralized security management (trusted switches)
- Fabric-wide security policies to control access
- Port level access control
- Switch level access control
- Management access controls (Telnet, SNMP, HTTP, API)
- Encryption of management data such as passwords
- Strong and non-reputable authentication between switches
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7831) M48 FICON w/CUP Activation
Summary: This feature provides in-band management of the supported
SAN b-type switch and director products by System Automation for OS/390
or z/OS on IBM 9672 Parallel Enterprise G5 and G6 servers, and zSeries
900 and 990 servers.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: Requires M48 Advanced Security Activation #7823.
- Compatibility Conflicts: Cannot coexist with feature #7833.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7833) M48 FICON w/CUP Activation and Advanced Security Bundle
Summary: This feature provides the B32 FICON CUP and Advanced
Security Activation features in a single package to streamline ordering
and deployment.
- Minimum Number of Features per 2109-M48: None.
- Maximum Number of Features per 2109-M48: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Cannot coexist with feature #7831.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
Not available.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
© IBM Corporation 2005.
Back to top
|
|
|
|
|
|
|
|