IBM U.S. Sales Manual
Revised:  August 30, 2005.

Table of contents  Document options  IBM U.S. Product Life Cycle Dates Publications Abstract Features -- Specify/Special/Exchange Highlights Accessories Description Machine Elements Model Supplies Technical Description    
doprint  
 
IBM U.S. Product Life Cycle Dates
Type ModelAnnounced AvailableMarketing Withdrawn Service DiscontinuedReplaced By
2109-M48 2005/07/262005/08/05 - - -


 
Abstract

The IBM 2109 SAN Fibre Channel Switch is used to interconnect multiple host servers with storage servers and devices, creating a Storage Area Network (SAN).

Model Abstract 2109-M48

The IBM 2109 SAN256B director Model M48 is designed for mid-range to enterprise level SAN applications and includes a minimum of two control processors, dual power supplies, and fans in a 14U rack height.
Back to topBack to top
 

Highlights

The IBM SAN Fibre Channel Switch offers:

  • Scalability from small- to very large-size SAN environments
  • Modularity for flexible system configurations, including diagnostics to isolate problems quickly
  • Support for Public Fibre Channel Arbitrated Loops

Model Highlights 2109-M48

The TotalStorage SAN256B director is designed to offer:

  • 4 Gbps industry-standard Fibre Channel (FC) switch capability for systems that support 4 Gbps throughput

  • Next generation enterprise director performance, scalability, flexibility, reliability, availability, and compatibility with IBM SAN Switches

  • Up to 256-port fabric director with single domain to help provide greater scalability, faster Control Processor Blades for low latency Fabric Services, and improved performance

  • 4, 2 and 1 Gbps auto-sensing capability, Full Fabric operation and Universal Port operation on all ports (F_Port, FL_Port, and E_Port)

  • SAN256B director base model includes Inter Switch Link (ISL) Trunking, Advanced Zoning, Web Tools, Fabric Watch, Performance Monitor and Hot Code Activation

  • SAN256B director optional features include Remote Switches, Extended Fabrics, Advanced Security and FICON with CUP activation.

Back to topBack to top
 
Description

The IBM 2109 TotalStorage SAN 256B director:

  • Is designed to deliver next generation enterprise director performance, scalability, flexibility, reliability, and availability

  • Is designed to provide a single domain with 256-port Fabric Switch functionality, yielding greater scalability with fewer domains, faster Control Processor Blades for low latency Fabric OS services, as well as improved performance over the IBM TotalStorage SAN Switch M14

  • Offers forward and backward compatibility with all IBM TotalStorage SAN Switch models, 1, 2 and 4 Gbps auto-sensing capability, as well as Advanced Fabric Services and management tools

Designed for mid-range to enterprise level SAN applications, the SAN256B director includes a minimum of two control processors, dual power supplies, and fans in a 14U rack height. The SAN256B director base model includes the following functions:

  • Full Fabric operation and Universal Port operation on all ports (F_Port, FL_Port, and E_Port). Requires ordering at least one of the optional blades listed below. IBM recommends deployment of at least two blades per director to enable high availability configurations.

  • Inter Switch Link (ISL) Trunking, Advanced Zoning.

  • Web tools, Fabric Watch, Performance Monitor.

  • Fabric OS 5.0, Hot Code Activation.

Several optional features are available for the director, including the following:

  • M48 32-Port 4 Gbps Switch Blades

  • M48 16-Port 4 Gbps Switch Blades

  • 4 Gbps short wave transceivers

  • 2 Gbps long wave transceivers

  • Extended Fabric Activation feature to increase ISL buffer credits to support disaster tolerance solutions with up to 70 km distance between sites

  • Advanced Security Activation to enable policy-based security mechanisms integrated within Fabric Operating System

  • FICON operation with CUP and optional Advanced Security

  • Optional features for director installation into 2109-C36 Cabinet

IBM TotalStorage SAN256B director (2109-M48)

The IBM TotalStorage SAN256B director is designed to support up to eight, 32-port Fibre Channel switch blades enabling a single domain director with up to 256 universal (E, F, and FL), full duplex, auto-sensing ports in a single 14U enclosure. Each port is capable of self-negotiation to the highest speed supported by the attached SAN infrastructure, operating at either 1, 2 or 4 Gbps throughput. Distances up to 10 km, 35 km, or 80 km are supported using the appropriate optional long wave laser 2 Gbps transceivers and 9.0u fiber cables. Short wave laser transceivers support distances up to 500m at 1 Gbps and up to 300m at 2 Gbps or 150m at 4 Gbps with 50.0u fiber cables.

The SAN256B director is designed to provide high availability features including:

  • Full Fabric operation and Universal Port operation on all M48 ports (F_Port, FL_Port, and E_Port)

  • Dual-redundant control processors (active/standby) designed to provide automatic control processor failover

  • Many non-disruptive software upgrades

  • Hot-swappable switch blades

  • Hot-swappable power supplies in redundant power subsystem

  • Hot-swappable blowers in redundant cooling subsystem

  • Extensive diagnostics, and system monitoring capabilities integrated with Fabric OS management tools

  • Fabric Shortest Path First (FSPF) rerouting around failed links

Optional Features

The IBM TotalStorage SAN256B director is available with a number of selectable options. The base SAN256B director does not include switch blades which are available in either 32-or 16-port configurations. At least one switch blade is required for host and storage connectivity. The SAN256B may be configured by adding up to eight 32-port (#3432) or 16-port (#3416) switch blades and a mixture of short wave and long wave optical transceivers up to the maximum 256 ports.

The SAN256B director will require fiber optic cables for connection to the host systems, and storage systems or devices. These cables can be supplied by the customer, or ordered with the switch.

Additional features for the SAN256B director include:

  • 4 Gbps short wave SFP transceiver four pack (#2414) - provides four short wave optical transceiver for SFP LC media.

  • 10 km 2 Gb LW SFP transceiver (#2320) - provides 10 km capable long wave 2 Gb optical transceiver for SFP 9 micron LC media.

  • 10 km 2 Gb LW SFP transceiver four pack (#2324) - provides four 10 km capable long wave 2 Gb optical transceiver for SFP 9 micron LC media.

  • 35 km Extended Distance LW SFP Transceiver (#2335) - provides extended distance long wave optical transceiver for SFP 9 micron LC media.

  • 80 km Extended Distance LW SFP Transceiver (#2380) - provides extended distance long wave optical transceiver for SFP 9 micron LC media.

  • M48 32-port 4 Gbps Switch Blade (#3432) - provides one 4 Gbps, 32-port switch blade

  • M48 16-port 4 Gbps Switch Blade (#3416) - provides one 4 Gbps, 16-port switch blade.

  • M48 Remote Switch Activation (#7802) - provides license key to enable the interconnection of two SAN Switches with a pair of CNT's Open System Gateways across an asynchronous transfer mode (ATM) wide area network.

  • M48 Extended Fabric Activation (#7803) - provides license key that helps optimize the management of the internal switch buffers to maintain performance on Inter-Switch Links (ISL) at distances greater than 10 km, and up to 70 km, utilizing selected fiber cable extension mechanisms

  • M48 Advanced Security Activation (#7823) - enables policy-based security mechanisms integrated within Fabric Operating System Versions 2.6, 3.1, 4.1 and 5.0. To enable Advanced Security capabilities, all switches within the IBM SAN Switches Fabric must be configured with their respective Fabric OS version (2.6, 3.1, 4.1 and 5.0) before activating the Advanced Security optional feature license key. When activated across the IBM SAN Switch Fabric, the Advanced Security Activation feature is designed to provide the following comprehensive security capabilities:
    • Centralized security management (trusted switches)
    • Fabric-wide security policies to control access
    • Port-level access control
    • Switch level access control
    • Management access controls (Telnet, SNMP, HTTP, API)
    • Encryption of management data such as passwords
    • Strong and non-reputable authentication between switches

  • M48 FICON with CUP activation (#7831) - provides IBM eServer zSeries FICON support

  • M48 FICON with CUP activation and Advanced Security Bundle (#7832) - provides both IBM eServer zSeries FICON support (#7831) and Advanced Security (#7823) in one bundle

  • First M48 installed in 2109-C36 (#9241) - provides installation of first 2109-M48 in 2109-C36.

  • Second M48 installed in 2109-C36 (#9242) - provides installation of a second 2109-M48 in 2109-C36.

  • Field Merge M48 in 2109-C36 (#9243) - provides plant hardware for installing 2109-M48 in existing customer 2109-C36

Supported Servers and Storage Systems

The IBM TotalStorage SAN Switch M48 is designed to support Fibre Channel connectivity for the following:

Servers:

  • IBM eServer zSeries and selected S/390 servers
  • IBM eServer pSeries and selected RS/6000 servers
  • IBM eServer iSeries and selected AS/400 servers
  • IBM eServer xSeries and selected Netfinity servers
  • Other Intel-based servers with Linux, and Microsoft Windows 2000 and Windows 2003
  • Selected Sun and HP servers

Storage Systems:

  • IBM TotalStorage DS8000
  • IBM TotalStorage DS6000
  • IBM TotalStorage DS4000
  • IBM TotalStorage Enterprise Storage Server
  • IBM TotalStorage FAStT Family of Storage Servers
  • IBM TotalStorage 3580, 3588, 3590, and 3592 Tape Drives
  • IBM TotalStorage 3494, 3582, 3583, and 3584 Tape Libraries
  • IBM TotalStorage 3581 Tape Autoloader
  • IBM TotalStorage 3584 High Availability Frame Model HA1
  • Other selected storage systems

For specific support dates, configuration options, server models, operating systems levels, attachment capabilities, and throughput connectivity speeds, visit:

http://www.ibm.com/totalstorage/san/b-type

Back to topBack to top
 
Model

Model Summary Matrix

Model FC Ports Transceivers
M48 0-256 0-256

Customer Setup (CSU)

No.

Devices Supported

Specific details on supported devices; storage products attachability, SAN connectivity products, and configuration options are available on the Web at:

http://www.ibm.com/totalstorage/san/b-type

Model Conversions

None.
Back to topBack to top
 
Technical Description
TOC Link Physical Specifications TOC Link Operating Environment TOC Link Limitations
TOC Link Hardware Requirements TOC Link Software Requirements

The IBM TotalStorage SAN256B director is designed to support up to eight, sixteen-port or thirty two-port Fibre Channel switch blades enabling a single domain core fabric switch with 256 universal (E, F, and FL), full duplex, auto-sensing ports in a single 14U enclosure. Each port is capable of self-negotiation to the highest speed supported by the attached SAN infrastructure, operating at either 1, 2, or 4 Gbps throughput. Distances up to 10 km, 35 Km, or 80 Km are supported using the appropriate optional long wave laser transceiver and 9.0u fiber cables. Short wave laser transceivers support distances up to 500m at 1 Gb or up to 300m at 2 Gbps or 150m at 4 Gbps with 50.0u fiber cables. The SAN256B director is designed to provide high availability features including:

  • Dual-redundant control processors (active/standby) designed to provide automatic control processor fail over

  • Many non-disruptive software upgrades

  • Hot-swappable switch blades

  • Hot-swappable power supplies in redundant power subsystem

  • Hot-swappable blowers in redundant cooling subsystem

  • Extensive diagnostics, and system monitoring capabilities integrated with Fabric OS management tools

  • Fabric Shortest Path First (FSPF) rerouting around failed links.

The SAN256B director base model includes a minimum of zero switch blades, zero fiber optic transceivers, two control processors, dual power supplies, and fans in 14U rack height. Customers will need to order either the 32-Port or 16-Port 4 Gbps M48 switch blades. Functionality in the SAN256B director base model includes the following:

  • Full Fabric operation and Universal Port operation on all M48 ports (F_Port, FL_Port, and E_Port)
  • Inter Switch Link (ISL) Trunking, Advanced Zoning
  • Web tools, Fabric Watch, Performance Monitor
  • Fabric OS 5.0, Hot Code Activation

Physical Specifications

The IBM TotalStorage SAN256B is only available for installation in the IBM TotalStorage SAN Switch Cabinet C36.

2109-M48 (14U):

  • Width: 43.74 cm (17.22 in)
  • Height: 61.24 cm (24.11 in)
  • Depth (without door): 70.90 cm (27.90 in.)
  • Depth (with door): 74.20 cm (29.20 in)
  • Weight (without media): 95 to 98 kg (210 to 216 lb)
  • Weight (empty chassis): 47 kg (104 lbs)

2109-C36 (36U):

  • Height: 1804 mm (71.0 in)
  • Width (with side panels): 644 mm (25.4 in)
  • Depth (with front/rear doors): 1098 mm (43.3 in)
  • Weight (2 M48s): 816 kg (1795 lb)

Operating Environment

IBM TotalStorage SAN256B (2109-M48)

  • Temperature:
    • Ambient Operating: 0 to 40.0 degrees C
    • Non-operating: -40 to 70 degrees C

  • Humidity Ambient Operating:
    • 20% to 85% non-condensing at 40 C
    • Non-operating and storage (non-condensing): 10% to 93%

  • Altitude Operating: 0 to 3 km

  • Shock Operating: 20 G, 11 ms, half sine 1G p-p, 5-500Hz, 1 octave/min

  • Shock Non-operating: 33 G, 11 ms, half sine 2.4G p-p, 5-500Hz, 1 octave/min

  • Vibration Operating: 5G p-p, 0 to 3kHz at 1.0 octave min

  • Vibration Non-operating: 10G p-p, 0 to 5 kHz at 1.0 octave min

  • Power: a maximum of 1500 Volt-Amps, 6.4 amps at 240V AC line voltage or 7.2 amps at 208V AC line voltage.

EMC Conformance:

  • ICES 003 Class A
  • FCC Part 15 Class A
  • VCCI Class A ITE
  • EN55022 Class A
  • EN55024
  • AS NZS 3548 Class A
  • CISPR22 Class A

Product Safety/Country Testing/Certification:

  • CSA 60950 (Canada)
  • UL Standard 60950
  • IEC EN60950 (CF-Europe)
  • EN60950 (Germany)
  • TUV, NEMKO
  • Argentina IRAM
  • Korea RRL
  • Russian Federation GOST GOST

Limitations

Due to the FCC Classification A and the acoustic sound rating for the IBM TotalStorage SAN256B (2109-M48), this product should not be installed in attended rooms. The SAN256B is used only in a typical commercial / industrial environment and not in a clean room.

The IBM TotalStorage SAN256B is supported only in the IBM TotalStorage SAN Switch Cabinet C36 (2109-C36).

Hardware Requirements

Specific details on supported operating systems, servers, and devices, storage products attachability, SAN connectivity products, and configuration options are available at:

http://www.ibm.com/totalstorage/san/b-type

Software Requirements

Specific details on supported operating system releases are available at:

http://www.ibm.com/totalstorage/san/b-type

Back to topBack to top
 
Publications

The following publications are shipped with the product.

Additional copies of individual publications are available on the Internet at:

http://www.ibm.com/totalstorage/san/b-type
                                             Order
           Title                             Number
------------------------------------------   ---------
IBM TotalStorage SAN256B Installation,       GC26-7761
Service, and User's Guide
IBM TotalStorage SAN Cabinet Model C36       GC26-7632
Installation and Service Guide
IBM eServer Translated Safety Notices        G229-9054
IBM TotalStorage SAN b-type 2109 Statement   GC26-7743
of Limited Warranty

Back to topBack to top
 
Features -- Specify/Special/Exchange
TOC Link No Charge Specify Codes TOC Link Special Feature Codes -- Chargeable TOC Link Feature Exchanges

No Charge Specify Codes

IBM TotalStorage SAN256B

Description                          Machine   Model   Feature
---------------------------------    -------   -----   -------
IBM TotalStorage SAN256B               2109     M48
 First M48 Installed in 2109-C36                         9241 (IPO)
 Second M48 Installed in 2109-C36                        9242 (IPO)
 Field Install M48 in 2109-C36                           9243 (IPO)
 

Installation

Summary: The M48 is supported only in the IBM TotalStorage SAN Switch Cabinet C36 (2109-C36). You must specify in your Initial Plant Order if one or two SAN256B directors will be plant installed in the 2109-C36. The only configuration supported in the C36 Cabinet is one or two SAN256B directors.

(#9241) First M48 Installed in the 2109-C36

Summary: This feature specifies that this is the first SAN256B to be installed into the C36 Cabinet during manufacture. This M48 will be located in the lower portion of the cabinet

(#9242) Second M48 Installed in the 2109-C36

Summary: This feature specifies that this is the second SAN256B to be installed into the C36 Cabinet during manufacture. This M48 will be located in the upper portion of the cabinet.

When specifying either feature #9241 or #9242 on your initial order, you must also indicate the corresponding quantity of SAN256B directors (maximum is two) to be installed in the C36 Cabinet by specifying 2109-C36 feature #9240. The C36 Cabinet along with one or two SAN256B directors must be grouped on the same system order.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: 2109-C36 with #9240.
  • Compatibility Conflicts: #9242 and #9243 can not coexist.
  • Compatibility Conflicts: Must specify either #9241, #9242 or #9243 on each SAN256B director initial order.
  • Customer Setup: No.
  • Limitations: None.
  • Initial Plant Order: Yes.
  • Field Installable: No, Initial Plant Order Only.
  • Cable Order: None.

(#9243) Field Install M48 in 2109-C36

Summary: This feature indicates that a 2109-C36 Cabinet already exists at the customer's location, and the M48 being ordered will be the second SAN256B director installed in the C36 Cabinet. There must be 14U of contiguous space available in the cabinet to allow field installation of the M48 SAN256B director.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: A 2109-C36 Cabinet must already exist in the customer's location to order a new M48 with #9243.
  • Corequisites: Existing C36 Cabinet.
  • Compatibility Conflicts: #9242 and #9243 can not coexist.
  • Compatibility Conflicts: Must specify either #9241, #9242 or #9243 on each SAN256B director initial order. Can coexist with a 2109-M14 in the same cabinet.
  • Customer Setup: No.
  • Limitations: None.
  • Initial Plant Order: Yes, available only on new M48 orders.
  • Field Installable: No, initial plant orders only
  • Cable Order: None.

Special Feature Codes -- Chargeable

IBM TotalStorage SAN256B

Description                          Machine   Model   Feature
---------------------------------    -------   -----   -------
IBM TotalStorage SAN256B               2109     M48
 - 10 Km 2 Gbps LW SPF Transceiver                       2320
 - 10 Km 2 Gbps LW SFP Transceiver -  4-Pack             2324
 - 35 Km 2 Gbps Ext Dist LW SFP Transceiver              2335
 - 80 Km 2 Gbps Ext Dist LW SFP Transceiver              2380
 - 4 Gbps SW SFP Transceiver 4-Pack                      2414
 - M48 16-Port 4 Gbps Switch Blade                       3416
 - M48 32-port 4 Gbps Switch Blade                       3432
 - M14/M48 N_Port ID Virtualization                      4745
 - Fiber Cable LC/LC 1m multimode                        5301
 - Fiber Cable LC/LC 5m multimode                        5305
 - Fiber Cable LC/LC 25m multimode                       5325
 - SC/LC Coupling Cable                                  5371
 - LC/SC Coupling Cable 2m                               5372
 - 9 Micron Fibre Cable 31m, singlemode SC/LC            5730
 - 9 Micron Fibre Cable 31m, singlemode LC/LC            5731
 - 9 Micron Fibre Cable 2m, singlemode SC/LC             5732
 - M48 Remote Switch Activation                          7802
 - M48 Extended Fabric Activation                        7803
 - M48 Advanced Security Activation                      7823
 - M48 FICON w/CUP Activation                            7831
 - M48 FICON w/CUP, Advanced Security                    7833
 

SAN256B Configuration Options

The SAN256B may be configured by adding up to eight 32-port (#3432) or 16-port (#3416) switch blades and a mixture of short wave and long wave optical transceivers up to the maximum 256 ports.

Transceivers - Small Form-Factor Pluggable (SFP)

Summary: A minimum of sixteen SFPs are required for each 16-Port switch blade (#3416), or thirty-two SFPs for each 32-Port switch blade (#3432) ordered for the SAN256B director.

A mixture of short wave, long wave, or extended distance ports can be configured by adding up to a maximum of 256 optical transceivers. All available ports must be populated with SFPs.

(#2320) 2 Gbps Long wave SFP Transceiver

Summary: This feature provides one long wave SFP transceiver, designed to provide Fibre Channel connections at distances up to 10 Km (6.2 miles), while using the appropriate 9.0/125 micrometer single mode fiber optic cable.

(#2335) 35 Km Extended Distance 2 Gbps LW SFP Transceiver

Summary: This optional feature provides a Small Form factor Pluggable (SFP) fiber optic transceiver, designed for operation with single mode 9 micron fiber optic cables having distances up to 35 Km. The 35 Km Extended Distance Long wave (LW) SFP Transceiver is designed for full compatibility with the SAN256B director and can help support disaster tolerance solutions without the need for separate gateway integration.

(#2380) 80 Km Extended Distance 2 Gbps LW SFP Transceiver

Summary: This optional feature provides a Small Form factor Pluggable (SFP) fiber optic transceiver, designed for operation with single mode 9 micron fiber optic cables having distances up to 80 Km. The 80 Km Extended Distance Long wave (LW) SFP Transceiver is designed for full compatibility with the SAN256B director and can help support disaster tolerance solutions without the need for separate gateway integration.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: 255.
  • Prerequisites: None.
  • Corequisites: All available ports must be populated with SFPs
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Max totals of features #2320, #2335, and #2380.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

Transceivers - SFP 4-Packs

(#2324) 2 Gbps LW SFP Transceiver - 4 Pack

Summary: This feature provides an additional four long wave SFP transceivers, designed to provide 4 Gbps Fibre Channel connections at distances up to 10 Km (6.2 miles), while using the appropriate 9.0/125 micrometer single mode fiber optic cable.

(#2414) 4 Gbps SW SFP Transceiver - 4 Pack

Summary: This feature provides an additional four short wave SFP transceivers, designed to provide Fibre Channel connections at distances up to 150 meters while using the appropriate 50.0/125 micrometer fiber optic cable, and distances up to 70 meters while using the appropriate 62.5/125 micrometer fiber optic cable.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: 64.
  • Prerequisites: None.
  • Corequisites: All available ports must be populated with SFPs.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Min and Max are totals of features #2324, #2414.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

The total of Fiber Optic Transceiver features = (4 x #2414) + #2320 + (4 x #2324) + #2335 + #2380, and must be a minimum equal to the number of ports available with switch blades (#3416, and #3432), up to a maximum of 256.

Switch Blades

Summary: No switch blades are shipped on initial SAN256B orders unless selected. The base SAN256B director does not include switch blades which are available in either 32-or 16-port configurations. Requires ordering at least one of the optional blades listed below. IBM recommends deployment of at least two blades per director to enable high availability configurations.

The SAN256B may be configured by adding up to eight 32-port (#3432) or 16-port (#3416) switch blades and a mixture of short wave and long wave optical transceivers up to the maximum 256 ports.

(#3416) M48 16-Port 4 Gbps Switch Blade

Summary: This feature provides a 16-port 4 Gbps switch blade for the SAN256B.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: Eight.
  • Prerequisites: None.
  • Corequisites: All available (16) ports must be populated with SFPs
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Min and Max are totals of features #3416 and #3432.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#3432) M48 32-Port 4 Gbps Switch Blade

Summary: This feature provides a 32-port 4 Gbps switch blade for the SAN256B.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: Eight.
  • Prerequisites: None.
  • Corequisites: All available (32) ports must be populated with SFPs
  • Compatibility Conflicts: None.
  • Customer Set-up: No.
  • Limitations: Min and Max are totals of features #3416 and #3432.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#4745) M14/M48 N_Port ID Virtualization:

Summary: Activates N_Port ID Virtualization on the IBM TotalStorage SAN256B director. Requires Fabric OS V5, or higher.
  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: Requires Fabric OS Version 5 or higher
  • Corequisites: None
  • Compatibility Conflicts: None
  • Customer Setup: Yes
  • Limitations: None
  • Field Installable: Yes, both IPO and MES.

Fiber Optic Cables: Summary: A fiber optic cable is required for attaching the SAN256B to the host system adapters, or other storage area Fibre Channel components. The cable can be customer supplied, or ordered with the 2109-M48 in the lengths available. The attaching fiber cable must be 50.0/125 micrometers for distances up to 300 meters at 2 Gbps speed or 150 meters at 4 Gbps. The attaching fibre cable must be 62.5/125 micrometers for distances up to 175 meters at 2 Gbps speed or 70 meters at 4 Gbps. The connection is a LC connector type.

The maximum number of features allowed per SAN256B director is the total of #5301, #5305, and #5325.

(#5301) Fiber Cable LC/LC 1m multimode

(#5305) Fiber Cable LC/LC 5m multimode

(#5325) Fiber Cable LC/LC 25m multimode

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: 255.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Max. is total of #5301, #5305, and #5325
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#5371) SC/LC Coupling Cable

(#5372) LC/SC Coupling Cable 2m

The maximum number of features allowed per SAN256B director is the total of #5371, and #5372.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: 255.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Max. is total of #5371, and #5372
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#5730) 9 Micron Fibre Cable 31m, singlemode SC/LC

(#5731) 9 Micron Fibre Cable 31m, singlemode LC/LC

(#5732) 9 Micron Fibre Cable 2m, singlemode SC/LC

The maximum number of features allowed per SAN256B director is the total of #5730, #5731, and #5732.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: 255.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Max. is total of #5730, #5731, #5732.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

In many situations, the lengths and installation of fiber optic cables required will be unique to each customer's configuration and facility specifications. Product support services offered by IBM Global Services' Site and Connectivity Solutions can provide assistance for these unique cabling and installation requirements.

Advanced Functions

(#7802) M48 Remote Switch Activation

Summary: This feature provides a means to obtain the unique activation key necessary to enable the Remote Switch capability within the SAN256B director firmware. Remote Switch function is used on two SAN switches that are interconnected with a pair of CNT's Open System Gateways, providing the fibre channel to asynchronous transfer mode (ATM) conversion, across a wide-area network.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Only two IBM SAN b-type switches can be in a fabric with Remote Switch enabled.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7803) M48 Extended Fabric Activation

Summary: This feature provides a means to obtain the unique activation key necessary to enable the Extended Fabric capability within the SAN256B director firmware. Extended Fabric function provides extensions within the internal switch buffers to maintain performance with distances greater than ten kilometers, and up to eighty kilometers, by maximizing buffering between the selected switch interconnect links.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7823) M48 Advanced Security Activation

Summary: The IBM TotalStorage SAN Switch Advanced Security Activation optional feature enables policy-based security mechanisms integrated within Fabric Operating System Versions 2.6, 3.1, 4.1, and 5.0. To enable Advanced Security capabilities, all switches within the IBM SAN Switches Fabric must be configured with their respective Fabric OS version (2.6, 3.1, 4.1, and 5.0) before activating the Advanced Security optional feature license key. When activated across the IBM SAN Switch Fabric, the Advanced Security Activation feature is designed to provide the following security capabilities.

  • Centralized security management (trusted switches)
  • Fabric-wide security policies to control access
  • Port level access control
  • Switch level access control
  • Management access controls (Telnet, SNMP, HTTP, API)
  • Encryption of management data such as passwords
  • Strong and non-reputable authentication between switches
  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7831) M48 FICON w/CUP Activation

Summary: This feature provides in-band management of the supported SAN b-type switch and director products by System Automation for OS/390 or z/OS on IBM 9672 Parallel Enterprise G5 and G6 servers, and zSeries 900 and 990 servers.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: Requires M48 Advanced Security Activation #7823.
  • Compatibility Conflicts: Cannot coexist with feature #7833.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7833) M48 FICON w/CUP Activation and Advanced Security Bundle

Summary: This feature provides the B32 FICON CUP and Advanced Security Activation features in a single package to streamline ordering and deployment.

  • Minimum Number of Features per 2109-M48: None.
  • Maximum Number of Features per 2109-M48: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: Cannot coexist with feature #7831.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

Feature Exchanges

Not available.
Back to topBack to top
 
Accessories

None.

Customer Replacement Parts

None.
Back to topBack to top
 
Machine Elements

Not available.
Back to topBack to top
 
Supplies

None.

Diskettes

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Windows is a trademark of Microsoft Corporation.
 © IBM Corporation 2005.