IBM U.S. Sales Manual
Revised:  February 25, 2005.

Table of contents  Document options  IBM U.S. Product Life Cycle Dates Publications Abstract Features -- Specify/Special/Exchange Highlights Accessories Description Machine Elements Model Supplies Technical Description    
doprint  
 
IBM U.S. Product Life Cycle Dates
Type ModelAnnounced AvailableMarketing Withdrawn Service DiscontinuedReplaced By
2109-F16 2001/10/022001/10/12 2005/04/29 - 2005-H16


 
Abstract

The IBM 2109 SAN Fibre Channel Switch is used to interconnect multiple host servers with storage servers and devices, creating a Storage Area Network (SAN).

Model Abstract 2109-F16

(No Longer Available as of April 29, 2005)

The IBM 2109 SAN Switch Model F16 extends the broad range of scalable SAN connectivity solutions available from IBM for a wide variety of host and storage types. It includes sixteen nonblocking ports, each with full-duplex throughput at either 2 gigabits per second or 1 gigabit per second, and auto-sensing ports that self-negotiate to the highest speed supported by the attached server, storage, or switch. Hardware zoning is controlled at the port level, and software zoning is controlled at the worldwide name level.

The F16 provides support for high-speed data traffic with the Performance Bundle feature, which provides Inter-Switch Link (ISL) Trunking and Performance Monitoring. It provides Cascading support for flexibility in creating scalable fabric topologies. The Model F16 also comes with Brocade Web Tools, which provides a comprehensive set of management tools that support a Web browser interface for flexible, easy-to-use operations.
Back to topBack to top
 

Highlights

The IBM SAN Fibre Channel Switch offers:

  • Scalability from small-to very large-size SAN environments
  • Modularity for flexible system configurations, including diagnostics to isolate problems quickly
  • Support for Public Fibre Channel Arbitrated Loops

Model Highlights 2109-F16

  • 2 gigabit per second industry-standard Fibre Channel switch throughput

  • A high availability design with redundant power supplies, hot-pluggable components, and automatic path rerouting

  • An Inter-Switch Link Trunking option to combine up to four physical links into one logical high-speed trunk with up to 8 Gbps full-duplex throughput

  • A Performance Monitoring feature for end-to-end measurement of Fibre Channel traffic, including cyclic redundancy checking (CRC) error counts

  • Brocade Web Tools for fabric management

Back to topBack to top
 
Description

IBM introduces Model F16 of the IBM TotalStorage Storage Area Network (SAN) Switch family, providing up to 2 Gigabit Fibre Channel (FC) performance and additional functions to support the storage networking demands for higher security, throughput, and management controls. This model is a 16-port Fibre Channel switch based on a new generation of switch technology. It is designed to provide a 2 gigabit per second port-to-port throughput with auto-sensing capability for connecting to existing 1 gigabit per second host servers, storage, and switches, in a smaller 1U form factor, requiring half the space of the previous 16-port SAN Switch. This model is also designed to be fully interoperable with the current IBM SAN Switches (Models S08 and S16).

The IBM TotalStorage SAN Switch, Model F16, when compared to the previous IBM SAN Switches (S08 and S16), provides the enhanced, higher-performance connectivity necessary to make enterprise information accessible and available across multiple host systems, from various storage systems or devices forming a manageable storage area network (SAN). IBM SAN Switches are designed to enable storage resources to be shared efficiently and to scale rapidly to meet the demands by users for highly available, heterogeneous access to expanding storage pools. Utilizing the ANSI standard Fibre Channel interconnect technology, the Switch provides 2 gigabit per second (200 MB/s) transfer bandwidth on each Fibre Channel connection port. This model of the IBM SAN Switch is capable of supporting up to 16 ports for midrange to high-end enterprises. The IBM SAN Switch is designed to provide:

  • High performance with low latency. The Switch's nonblocking architecture provides multiple simultaneous connections, each capable of up to 2 gigabits per second, with maximum latency of 2 microseconds.

  • Universal ports that self-configure as F-ports, FL-ports, or E-ports.

  • Auto-sensing ports that will self-negotiate to the highest speed supported by the attached servers, storage, or switch.

  • Each port supports the new Small Form-Factor Pluggable (SFP) media with options for either shortwave optical connection for distances up to 300 meters, or longwave optical connections for distances up to 10 kilometers.

  • A smaller 1U package that can be either rack-mounted or used in a table-top configuration, with the option of a redundant power supply, providing a highly available switch.

  • Easy setup and configuration. Internal power-on self test and a Web browser interface usable from any Java-enabled browser on the Inter/intranet provide configuration monitoring and diagnostics.

  • Scalable SAN solutions. Cascading Switches enable flexibility in configurations to accommodate many different needs, and assure high availability and optimum performance. Connections to existing 2109 SAN Switches is supported, enabling an easy transition for existing Fibre Channel storage networks to the faster technology.

  • Brocade Web Tools, which allows you to control which host systems are logically connected to various storage systems and devices, providing security and access control.

  • Automatic Fabric discovery. The Switch allows external host and storage systems to discover other SAN-enabled systems that are connected to the connectivity infrastructure (fabric). This information is maintained within an internal name server database.

  • Distributed fabric services such a name serving, zoning, routing, and microcode upgrade.

  • Extended distance. The Switch can be configured with either shortwave or longwave Small Form-Factor Pluggable (SFP) transceivers, for distances up to 10 kilometers between connections.

Optional Features

The IBM SAN Switch, Model F16 has a number of selectable options. The base Switch contains eight shortwave SFP transceivers GBICs, providing eight Fibre Channel port connections. You can select, in increments of one, additional shortwave or longwave transceivers up to the maximum of 16 ports. A second power supply can be installed on the Switch, providing a redundant power supply. This enables dual-power source configurations to minimize power outages, and, with the hot-pluggable capability of the power supplies, typically allows for nondisruptive maintenance should a power supply fail. The IBM SAN Switch can be used in either rack-mounted or tabletop configurations. The Switch requires fiber optic cables for connection to the host systems, and storage systems or devices. These cables can be customer supplied, or ordered with the Switch. Additional features available for the IBM SAN Switch include:

  • Performance Bundle Activation - adds support for Inter-Switch Link Trunking with up to four links, or 8 gigabits per second bandwidth; and performance monitoring tools for measuring end-to-end activities.

  • Extended Fabric Activation - extends the internal switch buffers to maintain performance on Inter-Switch Links at distances greater than 10 kilometers, and up to 70 kilometers utilizing selected fiber cable extension mechanisms.

  • Remote Switch Activation - provides for the interconnection of two SAN Switches with a pair of CNT's Open System Gateways across an asynchronous transfer mode (ATM) wide area network.

Back to topBack to top
 
Model

Model Summary Matrix

Model FC Ports GBIC
F16 16 8 Shortwave

Customer Setup (CSU)

None.

Devices Supported

Specific details on supported devices; storage products attachability, SAN connectivity products, and configuration options are available on the Web at:

http://www.ibm.com/storage/FCSwitch

Model Conversions

None.
Back to topBack to top
 
Technical Description
TOC Link Physical Specifications TOC Link Operating Environment TOC Link Limitations
TOC Link Hardware Requirements TOC Link Software Requirements

Physical Specifications

The IBM SAN Switch can be configured for either rack-mount or tabletop use.

2109-F16 (1U)

  • Height (Rack-Mount): 4.33 cm (1.72 in)

  • Height (Tabletop): 4.72 cm (1.86 in)

  • Width: 42.86 cm (16.87 in)

  • Depth: 62.23 cm (24.51 in)

  • Weight:
    • Single power supply: 10.65 kg (23.5 lb)
    • Dual power supply: 12.70 kg (28.0 lb)

Operating Environment

  • Temperature:
    • Operating: 10 to 40.0 degrees C (50 to 104 degrees F)
    • Non operating: -35 to 65.0 degrees C (-31 to 147 degrees F)

  • Relative Humidity: 5 to 85% noncondensing @ 40 degrees C (104 degrees F)

  • Altitude: Up to 3,000 m (9,800 ft)

  • Shock: 4 Gg, 11 ms_sine low impulse

  • Vibration:
    • Operating: 5 G, 0-5 KHz @ 1.0 octave/minute
    • Non operating: 10 G, 0-5 KHz @ 1.0 octave/minute

  • Power (Operational Range): 85 - 264 V ac, 47 - 63 Hz

  • EMC Conformance:
    • FCC A
    • CISPR22 Class A
    • EN55022 Class A
    • VCCI Class A ITE
    • AS/NZS 3548 Class A
    • Taiwan BCIQ

  • Product Safety/Country Testing/Certification:
    • UL Standard 1950
    • CSA 950 (Canada)
    • IEC950/EN60950 (CF-Europe)
    • TUV EN60950 (Germany)

Limitations

Not applicable.

Hardware Requirements

Specific details on supported operating systems, servers, and devices, storage products attachability, SAN connectivity products, and configuration options are available on the Web at:

http://www.ibm.com/storage/FCSwitch

Software Requirements

Specific details on supported operating system releases are available on the Web at:

http://www.ibm.com/storage/FCSwitch

Back to topBack to top
 
Publications

The following publications are shipped with the product.

Additional copies of individual publications are available on the Internet at:

http://www.ibm.com/storage/FCSwitch
                                           Order
           Title                           Number
---------------------------------        ------------
IBM SAN Fibre Channel Switch 2109        GC26-7439
    Model F16 User's Guide
IBM SAN Fibre Channel Switch 2109        SY27-7623
    Model F16 Installation and
    Service Guide
 

Back to topBack to top
 
Features -- Specify/Special/Exchange
TOC Link No Charge Specify Codes TOC Link Special Feature Codes -- Chargeable TOC Link Feature Exchanges

No Charge Specify Codes

Description                                                Feature
-------------------------------------                      ----------
- Install into customer provided rack                      9204
- Plant F16 installed in C36 Cabinet                       9211 (IPO)
- Field F16 installed in C36 Cabinet                       9212
 

(#1736) Expedited Delivery Service Indicator

This feature number specifies that a system will be shipped to the customer with expedited 2 day delivery.

  • Attributes provided: None
  • Attributes required: None
  • For 2109-F16: (#1736)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

(#9205) Non-Rack Install

This feature will designate the 2109-xxx for a non-rack, tabletop usage. You must order one specify feature number 98xx to designate the country specific power cord.

  • Minimum Number of Features per 2109: None.
  • Maximum Number of Features per 2109: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: Yes.
  • Cable Order: None.

F16 Integration Specify Codes

(#9204) Install into Customer Provided Rack (Not C36)

Summary: This no-cost specify code designates the switch for integration into a customer provided rack using the default power cord, and indicates that the switch will not be integrated into the 2109-C36 cabinet.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: Each 2109-F16 must have either feature #9204, #9205, #9211, or #9212.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES
  • Cable Order: None.

(#9298) Plant Merge in 2146-V1A - SAN Integration Routing Code

This feature applies to the machine types that are integrated into the 2146-V1A. Each machine type must carry a routing code to ensure that the components are delivered to the plant merge location.

  • Minimum: None.
  • Maximum: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Limitations: None.
  • Plant Install/Field Install: Plant only.

Installation in 2109-C36 Cabinet

Summary: You can specify in your Initial Plant Order that up to three Model F16 switches can be installed in the Model C36 Cabinet at time of manufacturing by indicating feature #9211. Model F16s can also be field installed into a customers existing 2109-C36 Cabinet, if space is available, by specifying feature #9212.

(#9211) Plant Install F16 in 2109-C36

(No Longer Available as of April 29, 2005)

Summary: This no-cost specify code designates the 2109-F16 switch for integration into the 2109-C36, when the combination is initial plant order.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: Requires second power supply, feature #6203.
  • Corequisites: Requires 2109-C36 with feature #6801 and #9210.
  • Compatibility Conflicts: Each 2109-F16 must have either feature #9204, #9205, #9211, or #9212.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: No, IPO only.
  • Cable Order: None.

(#9212) F16 Field Install Into C36

(No Longer Available as of April 29, 2005)

Summary: This no-cost specify code designates the 2109-F16 switch for integration into an existing 2109-C36, which is already located at the customer site, and helps increment the number of 2109-F32 switches configured in the C36 cabinet. When selected as an MES, this no-cost specify code does not include labor for field installation of the 2109-F16 switch into the C36 cabinet.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: Requires second power supply, feature #6203.
  • Corequisites: Requires 2109-C36 with feature #6801 and #9210.
  • Compatibility Conflicts: Each 2109-F16 must have either feature #9204, #9205, #9211, or #9212.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

When specifying either feature #9211, or #9212, you must also indicate the corresponding quantity of F16s to be installed in the 2109-C36 Cabinet by specifying the quantity of feature #9210 on the Model C36 order. The Model C36 Cabinet along with one, two, or three Model F16 switches must be grouped on the same system order number.

Power Cords for Non-rack Install

You must specify the type of power cord required when ordering the 2109 for non-rack, tabletop use with feature number 9205. Two power cords are required when the additional power supply, feature number 6203 is ordered.

(#9800) Power Cord

This feature supplies a 125V, 10A, 2.8 meter line cord for Group 1 countries.

United States, Canada, Antigua, St. Lucia, St. Vincent, Dominica, Grenadines, Grenada, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Cayman Islands, Colombia, Costa Rica, Dominican Republic, El Salvador, Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Mexico, Panama, Peru, Suriname, Trinidad, Venezuela, Brazil, Japan, Korea, Nicaragua, Philippines, Taiwan, Vietnam, Albania, Eritrea, Saudi Arabia.

(#9820) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Group 2 countries.

Afganistan, Netherlands Antilles, French Polynesia Guinea, Indonesia, Armenia, Latvia, Angola, Austria, Belgium, Luxembourg, Belarus, Bosnia, Botswana, Bulgaria, Camaroon, Central Africa Republic, Czech Republic, Congo, Egypt, Finland, France, Germany, Greece, Hungary, Iceland, Kazakhstan, Kirghizstan, Lebanon, Liberia, Macedonia, Mali, Mauritania, Moldavia, Morocco, Mozambique, Netherlands, Norway, Poland, Portugal, Romania, Rwanda, Sao Tome and Principe, Senegal, Serbia, Slovenia, Slovakia, Spain, Sudan, Swaziland, Sweden, Syria, Arab Republic, Tunisia, Turkey, Ukraine, Russia, Uzbekistan, Zaire, Zimbabwe, Burundi, Cape Verde Islands, Estonia, Lesotho, Lichtenstein, Republic of Djibouti.

(#9825) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Group 3 countries.

Abu Dhabi, Brunei, Fiji, Hong Kong, Macao, Malaysia, Singapore, Bahrain, Cyprus, Gambia, Ghana, Iraq, Ireland, Jordan, Kenya, Kuwait, Malawi, Nepal, North Yemen, Nigeria, Oman, Qatar, Sierra Leone, Tanzania, Uganda, United Arab Emirites, United Kingdom, Zambia.

(#9829) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Group 4 countries.

Bangladesh, Myanmar, Sri Lanka, Pakistan, South Africa, India.

(#9830) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Group 5 countries.

Chile, Ethiopia, Italy, Libya, Malta, Somalia.

(#9821) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Denmark.

(#9827) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Israel.

(#9828) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Switzerland.

(#9831) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Australia, and New Zealand.

(#9833) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Thailand.

(#9834) Power Cord

This feature supplies a 250V, 10A, 2.8 meter line cord for Uruguay, Argentina, and Paraguay.

(#9840) Power Cord

This feature supplies a 250V, 6A, 2.8 meter line cord for Peoples Republic of China.

(#9986) Power Cord

This feature supplies a 125V, 10A, 1.8 meter line cord for U.S. usage.

  • Minimum Number of Features per 2109: None.
  • Maximum Number of Features per 2109: Two.
  • Prerequisites: None.
  • Corequisites: Feature number 9205.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: Yes.
  • Cable Order: None.

Special Feature Codes -- Chargeable

Description                             Machine   Model   Feature
------------------------------------    -------   -----   -------
IBM SAN Switch Model F16 - 16 Port      2109      F16
 Transceivers (SFP):
 - Shortwave Transceiver                                   2210
 - SW SFP Transceiver 4 Pack                               2214
 - Longwave Transceiver                                    2220
 - LW SFP Transceiver 4 Pack                               2224
 - 35 Km Ext Distance LW SFP Transceiver                   2235
 - 80 Km Ext Distance LW SFP Transceiver                   2280
 Fiber Optic Cables:
 - Fiber Cable LC/LC 1m multimode                          5601
 - Fiber Cable LC/LC 2m multimode                          5602
 - Fiber Cable LC/LC 5m multimode                          5605
 - Fiber Cable LC/LC 7m multimode                          5607
 - Fiber Cable LC/LC 25m multimode                         5625
 - Fiber Cable LC/LC 31m multimode                         5631
 - LC/SC Coupling Cable 2m                                 5702
 - Power Supply, Additional                                6203
 - Remote Switch Activation                                7302
 - Extended Fabric Activation                              7303
 - F16 Performance Bundle Activation                       7421
 

Transceivers - Small Form-Factor Pluggable (SPF)

The 2109-F16 IBM SAN Switch includes eight shortwave optical SPF ports, and the option to add an additional eight (16 total) longwave or shortwave ports to the 2109-F16.

(#2210) Additional Shortwave Transceiver

This feature provides an additional shortwave transceiver allowing Fibre Channel connections of up to 500 meters (.31 miles).

(#2220) Additional Longwave Transceiver

This feature provides an additional longwave transceiver allowing Fibre Channel connections of up to 10.0 Km (6.2 miles).

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: Eight.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Maximum is total of both 2210 and 2220.
  • Field Installable: Yes.
  • Cable Order: None.

(#2235) 35 Km Extended Distance LW SFP Transceiver

Summary: This optional feature provides a Small Form factor Pluggable (SFP) fiber optic transceiver, designed for operation with single mode 9 micron fiber optic cables having distances up to 35 Km. The 35 Km Extended Distance Longwave (LW) SFP Transceiver is designed to help disaster tolerance solutions without the need for separate gateway integration.

(#2280) 80 Km Extended Distance LW SFP Transceiver

Summary: This optional feature provides a Small Form factor Pluggable (SFP) fiber optic transceiver, designed for operation with single mode 9 micron fiber optic cables having distances up to 80 Km. The 80 Km Extended Distance Longwave (LW) SFP Transceiver is designed to help disaster tolerance solutions without the need for separate gateway integration.
  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: Eight.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Min and Max are totals of features #2210, #2220, #2235, and #2280.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

Transceivers - SFP 4 Pack

(#2214) SW SFP Transceiver - 4 Pack

Summary: This feature provides an additional four shortwave SFP transceivers, designed to provide Fibre Channel connections at distances up to 300 meters while using the appropriate 50.0/125 micrometer fiber optic cable, and distances up to 175 meters while using the appropriate 62.5/125 micrometer fiber optic cable.

(#2224) LW SFP Transceiver - 4 Pack

Summary: This feature provides an additional four longwave SFP transceivers, designed to provide Fibre Channel connections at distances up to 10 Km(6.2 miles), while using the appropriate 9.0/125 micrometer single mode fiber optic cable.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: Two.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Min and Max are totals of features #2214, and #2224.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

Fiber Optic Cables

Summary: A fiber optic cable is required for attaching the IBM SAN Switch to the host system adapters, or other storage area Fibre Channel components. The cable can be customer supplied, or ordered with the 2109-M12 in the lengths available. The attaching fiber cable must be 50.0/125 micrometers for distances up to 300 meters, or 62.5/125 micrometers for distances up to 175 meters The connection is a LC connector type.

The maximum number of features allowed per F16 Switch is the total of #5601, #5605, #5625, #5602, #5607, and #5631.

(#5601) Fiber Cable LC/LC 1m multimode

(#5602) Fiber Cable LC/LC 2m multimode

(No Longer Available as of August, 16, 2002)

(#5605) Fiber Cable LC/LC 5m multimode

(#5607) Fiber Cable LC/LC 7m multimode

(No Longer Available as of August, 16, 2002)

(#5625) Fiber Cable LC/LC 25m multimode

(#5631) Fiber Cable LC/LC 31m multimode

(No Longer Available as of August, 16, 2002)

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: Sixteen
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Maximum is total of #5601, #5605, #5625, #5602, #5607, and #5631.
  • Initial Plant Order: Yes.
  • Field Installable: Yes.
  • Cable Order: None.

Fiber Optic Cable

Summary: A fiber optic cable is required for attaching the IBM TotalStorage SAN Switch to the host system adapters, or other storage area Fibre Channel components. The cable can be customer supplied, or ordered with the 2109-xxx in the lengths available. The attaching fiber cable must be 50.0/125 micrometers for distances up to 300 meters, or 62.5/125 micrometers for distances up to 175 meters. The connection is a LC connector type.

(#5701) SC/LC Coupling Cable

This feature supplies an 8-inch, SC (male)/LC (female) coupling cable.

(#5702) LC/SC Coupling Cable 2m

This feature supplies a 2-meter, LC (male)/SC (female) coupling cable.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: 16.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: Maximum is total of 5701, and 5702.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

In many situations, the required lengths and installation of fiber optic cables will be unique to each customer's configuration and facility specifications. Product support services offered by IBM Global Services' Site and Connectivity Solutions can provide assistance for these unique cabling and installation requirements. But for situations where the fibre channel components and attaching subsystems are within the distances available, there are several features available to accommodate these simple installations.

More Features

(#6203) Power Supply, Additional

(No Longer Available as of April 29, 2005)

This feature provides an additional power supply for the 2109. For rack mounted installation, a Power Distribution Unit (PDU) rack jumper cord is provided. When ordering an additional power supply for use in a tabletop configuration (#9205) a second power cord, feature number 98xx is required.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Field Installable: Yes.
  • Cable Order: None.

(#7202) Fabric Manager V3 Max Domains

(No Longer Available as of October 15, 2004)

Summary: This feature provides a Java-based application that can simplify management of a multiple switch fabric. Brocade Web Tools and Fabric Manager run on the same management server attached to any switch in the core/edge fabric. It may also manage up to eight fabrics. Fabric Manager requires a Windows NT/2K or Solaris 7 server with a Netscape or Internet Explorer Web browser.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Initial Plant Order: Yes, both IPO and MES.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7203) Fabric Manager V4 Max Domains

Summary: The IBM TotalStorage SAN Switch Fabric Manager V4.0 optional feature is designed to provide enhanced capabilities to the Java-based Fabric Manager application to simplify management of up to eight fabrics. The new Fabric Manager V4.0 optional feature provides enhanced security management, additional RAS features, and call home capabilities. Fabric Manager V4.0 requires a Windows NT/2000 or Solaris 7 server with a Netscape or Internet Explorer Web browser.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Set-up: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

(#7204) Fabric Manager V3 to V4 Upgrade Max Domains

(No Longer Available as of October 15, 2004)

Summary: The IBM TotalStorage SAN Switch Fabric Manager V4.0 Field Upgrade optional feature is designed to provide a Fabric Fabric Manager V4.0 Field Upgrade, for those customers who have already purchased Fabric Manager for their IBM TotalStorage SAN Switch fabric installation. The new Fabric Manager V4.0 optional feature provides Fabric Manager V4.0 requires a Windows NT/2000 or Solaris 7 server with a Netscape or Internet Explorer Web browser.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: Yes, feature number 7202
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Set-up: Yes.
  • Limitations: None.
  • Field Installable: Yes, MES Only.
  • Cable Order: None.

(#7302) Remote Switch Activation

This feature provides a means to obtain the unique activation key necessary to enable the Remote Switch capability within the SAN Switch Model F16 firmware. Remote Switch function is used on two SAN Switches that are interconnected with a pair of CNT's Open System Gateways, providing the Fibre Channel to asynchronous transfer mode (ATM) conversion, across a wide-area network; and with the Peer-to-Peer Remote Copy capability of the IBM Modular Storage Server (2106).

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: Only two IBM SAN Switches can be in a fabric with Remote Switch enabled.
  • Field Installable: Yes.
  • Cable Order: None.

(#7303) Extended Fabric Activation

This feature provides a means to obtain the unique activation key necessary to enable the Extended Fabric capability within the SAN Switch Model F16 firmware. Extended Fabric function provides extensions within the internal switch buffers to maintain performance with distances greater than ten kilometers, and up to seventy kilometers, by maximizing buffering between the selected switch interconnect links.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes.
  • Cable Order: None.

(#7421) F16 Performance Bundle Activation

This feature provides a means to obtain the unique activation key necessary to enable the Performance Bundle function within the SAN Switch Model F16 firmware. The Performance Bundle provides both Inter-Switch Link (ISL) Trunking and Performance Monitoring capabilities. The Trunking enables Fibre Channel packets to be distributed across up to four Inter-Switch connections (links) between two Model F16 SAN Switches providing up to eight gigabits per second of bandwidth and preserving in-order delivery. Both SAN Switches must have this feature activated.

  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Field Installable: Yes.
  • Cable Order: None.

(#7423) F16 Advanced Security Activation

Summary: The IBM TotalStorage SAN Switch Advanced Security Activation optional features enable policy-based security mechanisms integrated within Fabric Operating System V2.6, V3.1, and V4.1. To enable Advanced Security capabilities, all switches within the IBM SAN Switches Fabric must be configured with their respective Fabric OS version (2.6, 3.1, and 4.1) before activating the Advanced Security optional feature license key. When activated across the IBM SAN Switch Fabric, the Advanced Security Activation feature is designed to provide the following security capabilities:

  • Centralized security management (trusted switches)
  • Fabric-wide security policies to control access
  • Port level access control
  • Switch level access control
  • Management access controls (Telnet, SNMP, HTTP, API)
  • Encryption of management data such as passwords
  • Strong and non-reputable authentication between switches
  • Minimum Number of Features per 2109-F16: None.
  • Maximum Number of Features per 2109-F16: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Set-up: Yes.
  • Limitations: None.
  • Field Installable: Yes, both IPO and MES.
  • Cable Order: None.

Feature Exchanges

Not available.
Back to topBack to top
 
Accessories

None.

Customer Replacement Parts

None.
Back to topBack to top
 
Machine Elements

None.
Back to topBack to top
 
Supplies

None.

Diskettes

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.
 © IBM Corporation 2005.