Description Feature
------------------------------------- ----------
- Install into customer provided rack 9204
- Plant F16 installed in C36 Cabinet 9211 (IPO)
- Field F16 installed in C36 Cabinet 9212
(#1736) Expedited Delivery Service Indicator
This feature number specifies that a system will be shipped to the
customer with expedited 2 day delivery.
- Attributes provided: None
- Attributes required: None
- For 2109-F16: (#1736)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: Does not apply
- Return parts MES: Does not apply
(#9205) Non-Rack Install
This feature will designate the 2109-xxx for a non-rack, tabletop
usage. You must order one specify feature number 98xx to
designate the country specific power cord.
- Minimum Number of Features per 2109: None.
- Maximum Number of Features per 2109: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
F16 Integration Specify Codes
(#9204) Install into Customer Provided Rack (Not C36)
Summary: This no-cost specify code designates the switch for
integration into a customer provided rack using the default power cord,
and indicates that the switch will not be integrated into the 2109-C36
cabinet.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Each 2109-F16 must have either feature
#9204, #9205, #9211, or #9212.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#9298) Plant Merge in 2146-V1A - SAN Integration Routing Code
This feature applies to the machine types that are integrated into the
2146-V1A. Each machine type must carry a routing code to ensure that the
components are delivered to the plant merge location.
- Minimum: None.
- Maximum: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Limitations: None.
- Plant Install/Field Install: Plant only.
Installation in 2109-C36 Cabinet
Summary: You can specify in your Initial Plant Order that up to three
Model F16 switches can be installed in the Model C36 Cabinet at time of
manufacturing by indicating feature #9211. Model F16s can also be field
installed into a customers existing 2109-C36 Cabinet, if space is
available, by specifying feature #9212.
(#9211) Plant Install F16 in 2109-C36
(No Longer Available as of April 29, 2005)
Summary: This no-cost specify code designates the 2109-F16 switch for
integration into the 2109-C36, when the combination is initial plant
order.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: Requires second power supply, feature #6203.
- Corequisites: Requires 2109-C36 with feature #6801 and #9210.
- Compatibility Conflicts: Each 2109-F16 must have either feature
#9204, #9205, #9211, or #9212.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9212) F16 Field Install Into C36
(No Longer Available as of April 29, 2005)
Summary: This no-cost specify code designates the 2109-F16 switch for
integration into an existing 2109-C36, which is already located at the
customer site, and helps increment the number of 2109-F32 switches
configured in the C36 cabinet. When selected as an MES, this no-cost
specify code does not include labor for field installation of the
2109-F16 switch into the C36 cabinet.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: Requires second power supply, feature #6203.
- Corequisites: Requires 2109-C36 with feature #6801 and #9210.
- Compatibility Conflicts: Each 2109-F16 must have either feature
#9204, #9205, #9211, or #9212.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
When specifying either feature #9211, or #9212, you must also indicate
the corresponding quantity of F16s to be installed in the 2109-C36
Cabinet by specifying the quantity of feature #9210 on the Model C36
order. The Model C36 Cabinet along with one, two, or three Model F16
switches must be grouped on the same system order number.
Power Cords for Non-rack Install
You must specify the type of power cord required when ordering the
2109 for non-rack, tabletop use with feature number 9205. Two
power cords are required when the additional power supply, feature number
6203 is ordered.
(#9800) Power Cord
This feature supplies a 125V, 10A, 2.8 meter line cord for Group 1
countries.
United States, Canada, Antigua, St. Lucia, St. Vincent, Dominica,
Grenadines, Grenada, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia,
Cayman Islands, Colombia, Costa Rica, Dominican Republic, El Salvador,
Ecuador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Mexico, Panama,
Peru, Suriname, Trinidad, Venezuela, Brazil, Japan, Korea, Nicaragua,
Philippines, Taiwan, Vietnam, Albania, Eritrea, Saudi Arabia.
(#9820) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Group 2
countries.
Afganistan, Netherlands Antilles, French Polynesia Guinea, Indonesia,
Armenia, Latvia, Angola, Austria, Belgium, Luxembourg, Belarus, Bosnia,
Botswana, Bulgaria, Camaroon, Central Africa Republic, Czech Republic,
Congo, Egypt, Finland, France, Germany, Greece, Hungary, Iceland,
Kazakhstan, Kirghizstan, Lebanon, Liberia, Macedonia, Mali, Mauritania,
Moldavia, Morocco, Mozambique, Netherlands, Norway, Poland, Portugal,
Romania, Rwanda, Sao Tome and Principe, Senegal, Serbia, Slovenia,
Slovakia, Spain, Sudan, Swaziland, Sweden, Syria, Arab Republic, Tunisia,
Turkey, Ukraine, Russia, Uzbekistan, Zaire, Zimbabwe, Burundi, Cape Verde
Islands, Estonia, Lesotho, Lichtenstein, Republic of Djibouti.
(#9825) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Group 3
countries.
Abu Dhabi, Brunei, Fiji, Hong Kong, Macao, Malaysia, Singapore,
Bahrain, Cyprus, Gambia, Ghana, Iraq, Ireland, Jordan, Kenya, Kuwait,
Malawi, Nepal, North Yemen, Nigeria, Oman, Qatar, Sierra Leone, Tanzania,
Uganda, United Arab Emirites, United Kingdom, Zambia.
(#9829) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Group 4
countries.
Bangladesh, Myanmar, Sri Lanka, Pakistan, South Africa, India.
(#9830) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Group 5
countries.
Chile, Ethiopia, Italy, Libya, Malta, Somalia.
(#9821) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Denmark.
(#9827) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Israel.
(#9828) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for
Switzerland.
(#9831) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Australia,
and New Zealand.
(#9833) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Thailand.
(#9834) Power Cord
This feature supplies a 250V, 10A, 2.8 meter line cord for Uruguay,
Argentina, and Paraguay.
(#9840) Power Cord
This feature supplies a 250V, 6A, 2.8 meter line cord for Peoples
Republic of China.
(#9986) Power Cord
This feature supplies a 125V, 10A, 1.8 meter line cord for U.S. usage.
- Minimum Number of Features per 2109: None.
- Maximum Number of Features per 2109: Two.
- Prerequisites: None.
- Corequisites: Feature number 9205.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
Description Machine Model Feature
------------------------------------ ------- ----- -------
IBM SAN Switch Model F16 - 16 Port 2109 F16
Transceivers (SFP):
- Shortwave Transceiver 2210
- SW SFP Transceiver 4 Pack 2214
- Longwave Transceiver 2220
- LW SFP Transceiver 4 Pack 2224
- 35 Km Ext Distance LW SFP Transceiver 2235
- 80 Km Ext Distance LW SFP Transceiver 2280
Fiber Optic Cables:
- Fiber Cable LC/LC 1m multimode 5601
- Fiber Cable LC/LC 2m multimode 5602
- Fiber Cable LC/LC 5m multimode 5605
- Fiber Cable LC/LC 7m multimode 5607
- Fiber Cable LC/LC 25m multimode 5625
- Fiber Cable LC/LC 31m multimode 5631
- LC/SC Coupling Cable 2m 5702
- Power Supply, Additional 6203
- Remote Switch Activation 7302
- Extended Fabric Activation 7303
- F16 Performance Bundle Activation 7421
Transceivers - Small Form-Factor Pluggable (SPF)
The 2109-F16 IBM SAN Switch includes eight shortwave optical SPF
ports, and the option to add an additional eight (16 total) longwave or
shortwave ports to the 2109-F16.
(#2210) Additional Shortwave Transceiver
This feature provides an additional shortwave transceiver allowing
Fibre Channel connections of up to 500 meters (.31 miles).
(#2220) Additional Longwave Transceiver
This feature provides an additional longwave transceiver allowing
Fibre Channel connections of up to 10.0 Km (6.2 miles).
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: Eight.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Maximum is total of both 2210 and 2220.
- Field Installable: Yes.
- Cable Order: None.
(#2235) 35 Km Extended Distance LW SFP Transceiver
Summary: This optional feature provides a Small Form factor Pluggable
(SFP) fiber optic transceiver, designed for operation with single mode 9
micron fiber optic cables having distances up to 35 Km. The 35 Km
Extended Distance Longwave (LW) SFP Transceiver is designed to help
disaster tolerance solutions without the need for separate gateway
integration.
(#2280) 80 Km Extended Distance LW SFP Transceiver
Summary: This optional feature provides a Small Form factor Pluggable
(SFP) fiber optic transceiver, designed for operation with single mode 9
micron fiber optic cables having distances up to 80 Km. The 80 Km
Extended Distance Longwave (LW) SFP Transceiver is designed to help
disaster tolerance solutions without the need for separate gateway
integration.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: Eight.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Min and Max are totals of features #2210, #2220, #2235,
and #2280.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Transceivers - SFP 4 Pack
(#2214) SW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four shortwave SFP
transceivers, designed to provide Fibre Channel connections at distances
up to 300 meters while using the appropriate 50.0/125 micrometer fiber
optic cable, and distances up to 175 meters while using the appropriate
62.5/125 micrometer fiber optic cable.
(#2224) LW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four longwave SFP
transceivers, designed to provide Fibre Channel connections at distances
up to 10 Km(6.2 miles), while using the appropriate 9.0/125 micrometer
single mode fiber optic cable.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Min and Max are totals of features #2214, and #2224.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Fiber Optic Cables
Summary: A fiber optic cable is required for attaching the IBM SAN
Switch to the host system adapters, or other storage area Fibre Channel
components. The cable can be customer supplied, or ordered with the
2109-M12 in the lengths available. The attaching fiber cable must be
50.0/125 micrometers for distances up to 300 meters, or 62.5/125
micrometers for distances up to 175 meters The connection is a LC
connector type.
The maximum number of features allowed per F16 Switch is the total of
#5601, #5605, #5625, #5602, #5607, and #5631.
(#5601) Fiber Cable LC/LC 1m multimode
(#5602) Fiber Cable LC/LC 2m multimode
(No Longer Available as of August, 16, 2002)
(#5605) Fiber Cable LC/LC 5m multimode
(#5607) Fiber Cable LC/LC 7m multimode
(No Longer Available as of August, 16, 2002)
(#5625) Fiber Cable LC/LC 25m multimode
(#5631) Fiber Cable LC/LC 31m multimode
(No Longer Available as of August, 16, 2002)
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: Sixteen
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Maximum is total of #5601, #5605, #5625, #5602, #5607,
and #5631.
- Initial Plant Order: Yes.
- Field Installable: Yes.
- Cable Order: None.
Fiber Optic Cable
Summary: A fiber optic cable is required for attaching the IBM
TotalStorage SAN Switch to the host system adapters, or other storage
area Fibre Channel components. The cable can be customer supplied, or
ordered with the 2109-xxx in the lengths available. The attaching fiber
cable must be 50.0/125 micrometers for distances up to 300 meters, or
62.5/125 micrometers for distances up to 175 meters. The connection is a
LC connector type.
(#5701) SC/LC Coupling Cable
This feature supplies an 8-inch, SC (male)/LC (female) coupling cable.
(#5702) LC/SC Coupling Cable 2m
This feature supplies a 2-meter, LC (male)/SC (female) coupling cable.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: 16.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Maximum is total of 5701, and 5702.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
In many situations, the required lengths and installation of fiber
optic cables will be unique to each customer's configuration and facility
specifications. Product support services offered by IBM Global Services'
Site and Connectivity Solutions can provide assistance for these unique
cabling and installation requirements. But for situations where the
fibre channel components and attaching subsystems are within the
distances available, there are several features available to accommodate
these simple installations.
More Features
(#6203) Power Supply, Additional
(No Longer Available as of April 29, 2005)
This feature provides an additional power supply for the 2109.
For rack mounted installation, a Power Distribution Unit (PDU) rack
jumper cord is provided. When ordering an additional power supply for
use in a tabletop configuration (#9205) a second power cord, feature
number 98xx is required.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#7202) Fabric Manager V3 Max Domains
(No Longer Available as of October 15, 2004)
Summary: This feature provides a Java-based application that can
simplify management of a multiple switch fabric. Brocade Web Tools and
Fabric Manager run on the same management server attached to any switch
in the core/edge fabric. It may also manage up to eight fabrics. Fabric
Manager requires a Windows NT/2K or Solaris 7 server with a Netscape or
Internet Explorer Web browser.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Initial Plant Order: Yes, both IPO and MES.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7203) Fabric Manager V4 Max Domains
Summary: The IBM TotalStorage SAN Switch Fabric Manager V4.0 optional
feature is designed to provide enhanced capabilities to the Java-based
Fabric Manager application to simplify management of up to eight fabrics.
The new Fabric Manager V4.0 optional feature provides enhanced security
management, additional RAS features, and call home capabilities. Fabric
Manager V4.0 requires a Windows NT/2000 or Solaris 7 server with a
Netscape or Internet Explorer Web browser.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Set-up: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7204) Fabric Manager V3 to V4 Upgrade Max Domains
(No Longer Available as of October 15, 2004)
Summary: The IBM TotalStorage SAN Switch Fabric Manager V4.0 Field
Upgrade optional feature is designed to provide a Fabric Fabric Manager
V4.0 Field Upgrade, for those customers who have already purchased Fabric
Manager for their IBM TotalStorage SAN Switch fabric installation. The
new Fabric Manager V4.0 optional feature provides Fabric Manager V4.0
requires a Windows NT/2000 or Solaris 7 server with a Netscape or
Internet Explorer Web browser.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: Yes, feature number 7202
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Set-up: Yes.
- Limitations: None.
- Field Installable: Yes, MES Only.
- Cable Order: None.
(#7302) Remote Switch Activation
This feature provides a means to obtain the unique activation key
necessary to enable the Remote Switch capability within the SAN Switch
Model F16 firmware. Remote Switch function is used on two SAN Switches
that are interconnected with a pair of CNT's Open System Gateways,
providing the Fibre Channel to asynchronous transfer mode (ATM)
conversion, across a wide-area network; and with the Peer-to-Peer Remote
Copy capability of the IBM Modular Storage Server (2106).
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Only two IBM SAN Switches can be in a fabric with
Remote Switch enabled.
- Field Installable: Yes.
- Cable Order: None.
(#7303) Extended Fabric Activation
This feature provides a means to obtain the unique activation key
necessary to enable the Extended Fabric capability within the SAN Switch
Model F16 firmware. Extended Fabric function provides extensions within
the internal switch buffers to maintain performance with distances
greater than ten kilometers, and up to seventy kilometers, by maximizing
buffering between the selected switch interconnect links.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#7421) F16 Performance Bundle Activation
This feature provides a means to obtain the unique activation key
necessary to enable the Performance Bundle function within the SAN Switch
Model F16 firmware. The Performance Bundle provides both Inter-Switch
Link (ISL) Trunking and Performance Monitoring capabilities. The
Trunking enables Fibre Channel packets to be distributed across up to
four Inter-Switch connections (links) between two Model F16 SAN Switches
providing up to eight gigabits per second of bandwidth and preserving
in-order delivery. Both SAN Switches must have this feature activated.
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#7423) F16 Advanced Security Activation
Summary: The IBM TotalStorage SAN Switch Advanced Security Activation
optional features enable policy-based security mechanisms integrated
within Fabric Operating System V2.6, V3.1, and V4.1. To enable Advanced
Security capabilities, all switches within the IBM SAN Switches Fabric
must be configured with their respective Fabric OS version (2.6, 3.1, and
4.1) before activating the Advanced Security optional feature license
key. When activated across the IBM SAN Switch Fabric, the Advanced
Security Activation feature is designed to provide the following security
capabilities:
- Centralized security management (trusted switches)
- Fabric-wide security policies to control access
- Port level access control
- Switch level access control
- Management access controls (Telnet, SNMP, HTTP, API)
- Encryption of management data such as passwords
- Strong and non-reputable authentication between switches
- Minimum Number of Features per 2109-F16: None.
- Maximum Number of Features per 2109-F16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Set-up: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
© IBM Corporation 2005.