Description Machine Model Feature
---------------------------- ------- ----- -------
IBM TotalStorage SAN Cabinet 2109 C36
Plant Installation:
- Designate number of 2109-M12 SAN Switches for 9200
Plant Installation in 2109-C36 Rack
- Designate number of 2109-F16 SAN Switches for 9210
Plant Installation in 2109-C36 Rack
- Designate number of 2109-F16 SAN Switches for 9220
Plant Installation in 2109-C36 Rack
- Designate number of 2109-M14 SAN Switches for 9230
Installation in 2109-C36 Rack
- Designate number of 2109-M48 SAN256B for 9240
Installation in 2109-C36 Rack
Language Nomenclature (Safety Labels):
- Language Group - US English 9300
- Language Group - French 9703
- Language Group - German 9704
- Language Group - Spanish 9708
- Language Group - Italian 9711
- Language Group - Canadian French 9712
- Language Group - Japanese 9714
- Language Group - Korean 9716
- Language Group - Hungarian 9719
- Language Group - Simplified Chinese (Peoples 9722
Republic of China)
- Language Group - Brazilian/Portuguese 9751
- Language Group - Greek 9754
Power Cords - Select one:
- Single-Phase (US/Canada) 9800
- Universal without wall plug connector (non-US/Canada) 9802
- Single-Phase (Australia) 9822
- Single-Phase (New Zealand) 9826
- Single-Phase (Korea) 9835
- Single-Phase (US Chicago) 9986
- Single-Phase (Group 1) 9824
Argentina, Bahamas, Bangladesh, Barbados,
Bermuda, Bolivia, Brunei, Chile, Colombia,
Costa Rica, Dominican Republic, Ecuador,
El Salvador, Guatemala, Guyana, Honduras,
Hong Kong, India, Indonesia, Jamaica, Japan,
Macao, Malaysia, Mexico, Myanmar, Netherlands
Antilles, Panama, Peoples Republic of China,
Peru, Philippines, Singapore, Sri Lanka,
Suriname, Taiwan, Trinidad, Uruguay, Venezuela
- Single-Phase (Group 2) 9823
Bahrain, Belgium, Botswana, Brazil, Egypt,
Ethiopia, France, Germany, Ghana, Greece,
Iceland, Iraq, Ireland, Italy, Kenya, Jordan,
Kuwait, Lebanon, Malawi, Nigeria, Norway, Oman,
Qatar, Saudi Arabia, Spain, Sudan, Tanzania,
Uganda, United Arab Emirates, United Kingdom,
Zaire, Zambia, Zimbabwe
IBM TotalStorage SAN Switch Cabinet C36
Installation
Summary: You must specify in your Initial Plant Order if one or two
Model M12 switches will be plant installed in the 2109-C36. The IBM
TotalStorage SAN Switch M12 is supported only in the IBM TotalStorage SAN
Switch Cabinet C36 (2109-C36). The only configuration supported in the
C36 Cabinet is one or two 2109-M12 switches.
(#9200) Designate Number of 2109-M12 Switches for Plant Installation
(No Longer Available as of February 25, 2005)
in a 2109-C36 Rack
This specify feature designates plant installation of the 2109-M12
switch in a 2109-C36.
- Minimum Number of Features per 2109-C36: One.
- Maximum Number of Features per 2109-C36: Two.
- Prerequisites: None.
- Corequisites: 2109-M12 #9201 or #9202.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes.
- Field Installable: No.
- Cable Order: None.
C36 integration specify code for SAN Switches
Summary: New no-additional-cost cabinet integration features are
introduced for the 2109-C36 Cabinet. When configured with one 2109-M12
or M14 Director, the C36 Cabinet is designed to support up to three
2109-F16 and two 2109-F32 SAN switches.
(#9210) Designate 2109-F16 Switches for Installation in C36 Cabinet
;p.(No Longer Available as of February 25, 2005)
Summary: This no-cost specify code helps configure a number of
2109-F16 switches integrated within the 2109-C36 cabinet. When selected
as an initial plant order, this no-cost specify code helps configure the
combination of switches and cabinet for delivery from the factory. When
selected as a MES, this no-cost specify code helps maintain the cabinet
configuration in the field.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: Three.
- Prerequisites: Requires PDU feature #6081 = 1.
- Corequisites: Requires 2109-F16 with feature #9211 or #9212.
- Compatibility Conflicts: Yes, space available in Cabinet
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#9220) Designate 2109-F32 Switches for Installation in C36 Cabinet
(No Longer Available as of October 28, 2005)
Summary: This no-cost specify code helps configure a number of
2109-F32 switches integrated within the 2109-C36 cabinet. When selected
as an initial plant order, this no-cost specify code helps configure the
combination of switches and cabinet for delivery from the factory. When
selected as a MES, this no-cost specify code helps maintain the cabinet
configuration in the field.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: Two.
- Prerequisites:
- Prerequisites: Requires PDU feature #6081 = 1.
- Corequisites: Requires 2109-F32 with feature #9221 or #9222.
- Compatibility Conflicts: Yes, space available in Cabinet
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#9230) Designate 2109-M14 Switches for Installation in C36 Cabinet
Summary: This no-cost specify code helps configure up to two 2109-M14
switches integrated within the 2109-C36 cabinet. When selected as an
initial plant order, this no-cost specify code helps configure the
combination of switches and cabinet for delivery from the factory. When
selected as a MES, this no-cost specify code helps maintain the cabinet
configuration in the field.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: Two.
- Prerequisites: None.
- Corequisites: Requires 2109-M14 with feature #9231, #9232, or #9233.
- Compatibility Conflicts: Yes, space available in Cabinet
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#9240) Designate 2109-M48 Switches for Installation in C36 Cabinet
Summary: This no-cost specify code helps configure up to two 2109-M48
directors integrated within the 2109-C36 cabinet. When selected as an
initial plant order, this no-cost specify code helps configure the
combination of directors and cabinet for delivery from the factory. When
selected as a MES, this no-cost specify code helps maintain the cabinet
configuration in the field.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: Two.
- Prerequisites: None.
- Corequisites: Requires 2109-M48 with feature #9241, #9242, or #9243.
- Compatibility Conflicts: Yes, space available in Cabinet
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
Language Nomenclature (Safety Labels)
Summary: Safety Labels are included with the hardware and if
translations are available they will be provided in the language based on
country code. If anything other than the standard language for that
country is required, it must be specified with one of the following
specify numbers:
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes.
- Field Installable: No.
- Cable Order: None.
Publication Language Specify Number
-------------------- --------------
- Language Group - US English 9300
- Language Group - French 9703
- Language Group - German 9704
- Language Group - Spanish 9708
- Language Group - Italian 9711
- Language Group - Canadian French 9712
- Language Group - Japanese 9714
- Language Group - Korean 9716
- Language Group - Hungarian 9719
- Language Group - Simplified Chinese (Peoples 9722
Republic of China)
- Language Group - Brazilian/Portuguese 9751
- Language Group - Greek 9754
Power Cords
Summary: You must specify the type of power cords required for the
two standard power distribution units (PDU). Two line cords are supplied
with each order.
- Minimum Number of Features per 2109-C36: One.
- Maximum Number of Features per 2109-C36: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes.
- Field Installable: No.
- Cable Order: None.
(#9800) Power Cord
This feature supplies two Single-Phase line cords for the US and
Canada.
(#9802) Power Cord
This feature supplies two Universal line cords without the wall plug
connector for non-US/Canada.
(#9822) Power Cord
This feature supplies two Single-Phase line cords for Australia.
(#9823) Power Cord
This feature supplies two Single-Phase line cords for Group 2
countries:
- Group 2 - Bahrain, Belgium, Botswana, Brazil, Egypt, Ethiopia,
France, Germany, Ghana, Greece, Iceland, Iraq, Ireland, Italy, Kenya,
Jordan, Kuwait, Lebanon, Malawi, Nigeria, Norway, Oman, Qatar, Saudi
Arabia, Spain, Sudan, Tanzania, Uganda, United Arab Emirates, United
Kingdom, Zaire, Zambia, Zimbabwe
(#9824) Power Cord
This feature supplies two Single-Phase line cords for Group 1
countries:
- Group 1 - Argentina, Bahamas, Bangladesh, Barbados, Bermuda, Bolivia,
Brunei, Chile, Colombia, Costa Rica, Dominican Republic, Ecuador, El
Salvador, Guatemala, Guyana, Honduras, Hong Kong, India, Indonesia,
Jamaica, Japan, Macao, Malaysia, Mexico, Myanmar, Netherlands Antilles,
Panama, Peoples Republic of China, Peru, Philippines, Singapore, Sri
Lanka, Suriname, Taiwan, Trinidad, Uruguay, Venezuela
(#9826) Power Cord
This feature supplies two Single-Phase line cords for New Zealand.
(#9835) Power Cord
This feature supplies two Single-Phase line cords for Korea.
(#9986) Power Cord
This feature supplies two Single-Phase line cords for US Chicago.
Description Machine Model Feature
----------------------------------- ------- ----- -------
IBM TotalStorage SAN Cabinet 2109 C36
Ruggedized Rack Feature 6080
PDU Pair for F-series installation 6081
IBM TotalStorage SAN Switch Cabinet C36
(#6080) Ruggedized Rack Feature
Summary: For enhanced rigidity and stability of the 2109-C36 Cabinet,
the optional Ruggedized Rack Feature provides additional hardware that
reinforces the cabinet and anchors it to the floor. This hardware is
designed primarily for use in locations where earthquakes are a concern.
The feature includes a large steel brace or truss that bolts into the
rear of the cabinet. It is hinged on the left side so it can swing out
of the way for each access to the cabinet drawers when necessary. The
Ruggedized Rack Feature also includes hardware for bolting the cabinet to
a concrete floor or a similar surface and bolt-in steel filler panels for
any unoccupied spaces in the cabinet. When a cabinet is bolted to the
floor, the front and rear anti-tilt plates are not necessary. Cabinets
ordered with this feature are shipped without the anti-tilt plates.
Instead, the base of the cabinet has an additional front trim panel.
This panel is designed to accommodate a standard AC Power outlet.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Initial Plant Order: Yes.
- Field Installable: Yes.
- Cable Order: None.
(#6081) PDU Pair for F-series switch installation
Summary: The C-36 PDU Pair For F-Series Switch optional feature
provides a pair of Power Distribution Units (PDU) required for
integration of 2109-F16 and 2109-F32 switches into a 2109-C36 cabinet.
This feature is mandatory before selecting feature #9210 or #9220 on the
2109-C36.
- Minimum Number of Features per 2109-C36: None.
- Maximum Number of Features per 2109-C36: One.
- Prerequisites: None.
- Corequisites: Feature #9210 or #9220.
- Compatibility Conflicts: Required for installation of 2109-F16 or
2109-F32 Switch into the C36 Cabinet.
- Customer Setup: No.
- Limitations: Can not coexisit with feature #9200 when second
2109-M12 is installed in cabinet. #9200, Maximum = 2.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
© IBM Corporation 2005.
Back to top
|
|
|
|