Description Machine Model Feature Min Max
---------------------------------- ------- ----- ------- --- ---
IBM TotalStorage SAN256N director 2045 N16
SAN256N North American Power Cord Bundle 9301 0 1
Installation:
Plant Install SAN256N into SANC40N Cabinet 9421 0 1
Field Install SAN256N into SANC40N Cabinet 9422 0 1
Country Kits:
U.S. 9601 0 1
Canada 9602 0 1
Mexico 9603 0 1
Argentina 9604 0 1
Brazil 9605 0 1
Chile 9606 0 1
Columbia 9607 0 1
Bolivia 9608 0 1
Ecuador 9609 0 1
Paraguay 9610 0 1
Peru 9611 0 1
Uruguay 9612 0 1
Venezuela 9613 0 1
IBM TotalStorage SANC40N Cabinet 2045 C40
Plant Install SAN256N into SANC40N Cabinet 9425 0 1
SANC40N Cabinet North America Shipping 9810 0 1
SANC40N Cabinet International Shipping 9811 0 1
SAN256N director features
Power Supply
Summary: You must specify the type of power required when ordering
IBM TotalStorage SAN256N director (2045-N16).
Specify the North American Power (#9301) for the United States,
Canada, or Mexico, and International Power (#9302) for all other
countries.
You must designate either feature number 9301 or 9302 in your initial
order. Power cords are included with the power supply.
(#9301) SAN256N Power Cord Bundle (North America)
(No Longer Available as of September 30, 2005)
Specify this feature for North American Power requirements (United
States, Canada, Mexico). This feature provides Cabinet power cords with
NEMA L6-20P connector.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must select either #9301 or #9302.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9302) SAN256N Power Cord Bundle (International)
(No Longer Available as of September 30, 2005)
Specify this feature for countries requiring International Power.
This feature provides Cabinet power cords with IEC 60309 connector.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must specify either #9301 or #9302.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9601 - 9686) Country Kits
Summary: You must specify the specific Country Kit as a
corequisite of feature #7600, Enterprise Manager Server Bundle.
Specify the appropriate Country Kit based on the installation location.
Features #9601-#9686 will provide the appropriate
power cords, monitor, modem, and phone line adapter, and appropriate
licenses.
- Minimum Number of Features per 2042-N16: None.
- Maximum Number of Features per 2042-N16: One.
- Corequisites: Required when ordering feature #7600.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
SAN256N cabinet installation features
(#9421) Plant Install SAN256N into SANC40N Cabinet
(No Longer Available as of September 30, 2005)
Specify this feature in your initial order of the IBM TotalStorage
SAN256N director to designate that the director will be plant installed
in a SANC40N (2045-C40) Cabinet.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: Requires 2045-C40 with #9425.
- Compatibility Conflicts: Must have 2045-C40 Cabinet on same order.
- Compatibility Conflicts: Must specifiy either #9421 or #9422 on each
2045-N16 order being installed into a 2045-C40 Cabinet.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9422) Field Install SAN256N into SANC40N Cabinet
(No Longer Available as of September 30, 2005)
Specify this feature in your initial order of the IBM TotalStorage
SAN256N director to designate that the director will be field installed
in an existing 2045-C40 Cabinet.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must have space available in existing
2045-C40 Cabinet.
- Compatibility Conflicts: Must specifiy either #9421 or #9422 on each
2045-N16 order being installed into a 2045-C40 Cabinet.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
SANC40N cabinet features
C40 cabinet installation codes
The IBM TotalStorage SANC40N cabinet (2045-C40) is designed to accept
up to two SAN256N directors (2045-N16). SAN256N directors may be
installed in the SANC40N 40U Cabinet at the plant or in the field for an
already installed SANC40N 40U Cabinet with available space.
(#9425) Plant Install SAN256N into SANC40N Cabinet
(No Longer Available as of September 30, 2005)
Specify this feature in your initial order of the IBM TotalStorage
SANC40N cabinet to designate that the IBM TotalStorage SAN256N director
will be plant installed in a 2045-C40 Cabinet.
- Minimum Number of Features per 2045-C40: One.
- Maximum Number of Features per 2045-C40: Two.
- Prerequisites: None.
- Corequisites: Requires 2045-N16 with #9421.
- Compatibility Conflicts: Must have 2045-N16 Director on same order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9810) SANC40N Cabinet North America Shipping
(No Longer Available as of September 30, 2005)
Specify this feature for North American shipping requirements (United
States, Canada, Mexico).
- Minimum Number of Features per 2045-C40: None.
- Maximum Number of Features per 2045-C40: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must specify either #9811 or #9812.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9811) SANC40N Cabinet International Shipping
(No Longer Available as of September 30, 2005)
Specify this feature for countries requiring International shipping.
- Minimum Number of Features per 2045-C40: None.
- Maximum Number of Features per 2045-C40: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must specify either #9811 or #9812.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
VOLTAGE:
A specify code for voltage/power is required.
Specify code Description
------------ -----------
9301 SAN256N North American Power Cord Bundle
Description Machine Model Feature Min Max
---------------------------------- ------- ----- ------- --- ---
IBM TotalStorage SAN256N director 2045 N16
Shortwave 2 Gbps SFP Transceiver - 4 Pack 2214 0 64
Longwave 2 Gbps SFP Transceiver - 4 Pack 2224 0 64
LW 35 Km SFP Transceiver 2235 0 128
LW 80 Km 2 Gbps SFP Transceiver 2280 0 128
10 Gbps XFP Transceiver 2390 0 4
Switch Module 5301 0 1
SAN256N 16 Port 2 Gbps Fibre Channel I/O Blade 5316 2 16
10 Gbps ISL + 12 2 Gb FC IO Blade 5390 0 4
5m, LC/LC Singlemode 9u Fiber Cable 5405 0 255
25m, LC/LC Singlemode 9u Fiber Cable 5425 0 255
5m,LC/LC Multimode 50u Fiber Cable 5605 0 255
25m, LC/LC Multimode 50u Fiber Cable 5625 0 255
SAN256N FICON CUP 7301 0 4
SAN256N FICON Cascading 7302 0 4
SAN256N SAN Services Bundle 7303 0 4
Enterprise Manager Server Bundle 7600 0 1
Ethernet Hub, 8 ports 7603 0 1
Ethernet Hub, 24 ports 7604 0 1
Vertical Fibre Cable Management Set 7640 0 1
Fiber Trunking Break-out box 7645 0 1
Single mode 64-port cable bundle 7646 0 4
Multimode 64-port cable bundle 7647 0 4
Single mode 6-port cable bundle 7650 0 11
Multimode 6-port cable bundle 7651 0 11
SAN256N features
SFP Transceivers
Summary: Fibre Channel ports on the SAN256N (2045-N16) director may
be configured with either shortwave (#2214) or longwave (#2224) SFP
transceivers, or for distances up to 35 Km or 80 Km, with the extended
distance longwave 2 Gb SFP tranceivers (#2235 or #2280).
Any combination of shortwave and longwave transceivers can be
configured for the 2 Gbps interfaces on the SAN n-type blades (#5316 and
#5390). The 10 Gbps interface on the 10 Gbps ISL I/O Blade (#5390)
requires a single form-factor pluggable transceiver, called an XFP,
designed for this link rate (#2390).
All available ports in the SAN256N director blades must have a
transceiver ordered. The total number of SFPs of all types required is
dependent upon the type and number of SAN256N blades ordered. Refer to
the SAN256N n-type Blades section for details.
(#2214) SW SFP Transceiver - 4 Pack
Summary: This feature provides an additional four shortwave
SFP transceivers, designed to provide Fibre Channel connections
at distances up to 300 meters while using the appropriate 50.0/125
micrometer fiber optic cable, and distances up to 175 meters while
using the appropriate 62.5/125 micrometer fiber optic cable.
(#2224) LW SFP Transceiver - 4 Pack:
Summary: This feature provides an additional four longwave
SFP transceivers, designed to provide Fibre Channel connections
at distances up to 10 Km (6.2 miles), while using the
appropriate 9.0/125 micrometer single mode fiber optic cable.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 64.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Combinations of all SFP Transceivers
must be ordered in increments equal to the number of available ports
on all SAN n-type blades ordered.
- Customer Setup: Yes.
- Limitations: Min and Max are totals of features #2214, and #2224.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#2235) Extended Distance 35 Km Longwave 2 Gbps SFP
Summary: The Extended Distance 35 Km Longwave 2 Gbps SFP option is
designed to provide extended, unrepeated distance up to 35 Km between
supported devices, while operating at 2 Gbps. Dedicated port
buffer credits within the SAN256N director are designed to
work with the 35 Km longwave 2 Gbps SFP to help users extend
FCP and FICON Inter-Switch Links (ISLs) up to 35 Km distance,
in campus environments or metropolitan area networks. The 35
Km longwave 2 Gbps SFP is designed to be hot pluggable for use
in any 1 or 2 Gbps port on the SAN256N n-type blades (#5316 and #5390).
(#2280) Extended Distance 80 Km Longwave 2 Gbps SFP
Summary: The Extended Distance 80 Km Long Wave 2 Gbps SFP option
is designed to provide (up to 80 km unrepeated) Inter-Switch Links (ISLs)
between SAN256N directors while operating at 2 Gbps, depending
upon optical cable quality of the customer-provided dark fiber
cable plant. The 80 Km Long Wave 2 Gbps SFP is designed to be
hot pluggable for use in any 1 or 2 Gbps port on the SAN256N I/O
blades (#5316 and #5390).
SAN256N I/O n-type blades support both shortwave and longwave SFP
transceivers on the same module.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 128.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Combinations of all SFP Transceivers
must be ordered in increments equal to the number of available ports
on all SAN n-type blades ordered.
- Customer Setup: Yes.
- Limitations: Max total is for features #2235, and #2280.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#2390) 10 Gbps XFP Transceiver with Digital Optical Monitoring 10 Km
Summary: The 10 Gbps interface on the 10 Gbps ISL Blade (#5390)
requires a single form-factor pluggable transceiver, called an XFP,
designed for this link rate. The XFP transceiver, designed to support
industry standards, can be used for unrepeated distances of 10 km, over
single mode fiber, and supports digital diagnostics for monitoring of
various laser health parameters. Distances up to 17 km are possible, at
full bi-directional 10 Gbps, with the use of repeating devices.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: Feature #5390.
- Compatibility Conflicts: Must order one #2390 for each #5390
ordered.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
SAN256N n-type Blades
The 16-slot, 256-port capable IBM TotalStorage SAN256N (IBM 2045-N16)
is available in configurations starting with a combination of any two
16 port Fibre Channel I/O and 10 Gbps ISL blades, providing growth
from 26 to 256 ports.
Available SAN n-type blades include:
- (#5316) 16 Port 2 Gbps Fibre Channel I/O Blade
- (#5390) 10 Gbps ISL Blade with twelve 2 Gbps interfaces plus
one 10 Gbps interface (13 ports total)
Blade quantities per N16 director:
- Minimum = 5316 + 5390 = 2
- Maximum = 5316 + 5390 = 16
All available ports must be populated with SFPs.
(#5301) Switch Module
Summary: The base 2045-N16 is configured with three switch
modules providing full bandwidth and non-blocking switch capability
for all ports even in the event of a loss or removal of any
switch module. This feature provides additional throughput for
configurations consisting of 10 Gbps and 256 ports.
The 10 Gbps ISL Blades (#5390) consume more
internal bandwidth than 16-port 2 Gbps Blades, but the 2045-N16
can still provide full, non-blocking switch capability for all ports
even with the loss of one of the switch modules
with this feature installed. This feature is a prerequisite for the
first 10 Gb ISL blade (#5390) to be installed in a 2045-N16.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: Required for first #5390 ordered.
- Compatibility Conflicts: None, does not require SFPs.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5316) 16 Port 2 Gbps Fibre Channel I/O Blade
Summary: This feature supplies an additional 16 port FC I/O blade.
On the SAN256N, you can add up to sixteen
16 port FC I/O Blades for a maximum of 256 ports.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 16.
- Prerequisites: None.
- Corequisites: Must order 16 2 Gbps SFPs: (4 x 2214)+(4 x 2224) +
2235 + 2280.
- Compatibility: All available ports must be populated with SFPs
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5390) 10 Gbps ISL Blade
Summary: This feature provides a 10 Gbps
Fibre Channel ISL (Inter-Switch Link) interface for consolidating
multiple physical 1 and 2 Gbps ISLs. Customers can easily reduce the
quantity of existing ISL cabling with this standards based, high speed
interface. The 10 Gbps interface accepts a single form-factor pluggable
transceiver, called an XFP, designed for this link rate (see feature
#2390). The 10 Gbps ISL blade also includes twelve standard 2 Gbps Fibre
Channel interfaces. These interfaces support all the same features as a
standard 16-port Fibre Channel I/O blade (#5316) and can use any mix of
the four different types of SFP's currently available (#2214, 2224, 2235,
2280). All ports are required to have SFPs installed. The 10 Gbps ISL
blade is hot-swappable into any available I/O blade slot and supports
non-disruptive code load and activation. The 2045-N16 can have up to
four 10 Gbps ISL blades installed within the same chassis. As a
prerequisite, the operation of a 10 Gbps ISL blade in a 2045-N16 requires
all four switch modules to be installed to maintain full system
bandwidth between all ports even in the event of a loss or removal of any
switch module. An additional switch module (#5301) must be ordered in
conjunction with the first 10 Gbps ISL blade.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: Feature #5301.
- Corequisites: Must order 12 2 Gbps SFPs: (4 x 2214)+(4 x 2224) +
2235 + 2280, and one 10 Gbps XFP, 2390.
- Compatibility: All available ports must be populated with SFPs
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Fiber Optic Cables
A fiber optic cable is required for attaching the IBM TotalStorage
SAN256N director port to the host system adapters, a fibre channel
storage subsystem, or another fibre channel SAN component. Fibre optical
cables are customer supplied to enable maximum flexibility and
compatibility in various environments, but where a limited distance
connection exists, fiber optic cables can be ordered with the CNT
products from IBM.
In many situations, the lengths and installation of fiber optic cables
required will be unique to each customer's configuration and facility
specifications. Product support services offered by IBM Global Services'
Site and Connectivity Solutions can provide assistance for these unique
cabling and installation requirements.
For situations, where the Fibre Channel Directors and attaching
subsystems are within twenty-five (or thirty) meters, and are using a
shortwave optical connection, there are two features now available to
accommodate these simple installations. Each feature provides a
multimode 50.0/125 micrometer fiber optic cable in the available length
with duplex SC connectors at both ends. Customer supplied fiber optic
cables for shortwave connections must be multimode 50.0/125 micrometers
for distances up to 500 meters, or multimode 62.5/125 micrometers for
distances up to 175 meters; for longwave connections the fiber cable must
be singlemode 9.0/125 micrometers for distances up to 10 kilometers. The
connector is a duplex SC type.
(#5405) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 5.0 meter
fiber optic cable with LC plug connections at both ends.
(#5425) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 25.0 meter
fiber optic cable with LC plug connections at both ends.
(#5605) Fibre Channel Cable
Summary: This feature supplies a multimode, 50.0 micron, 5.0 meter
fiber optic cable with LC plug connections at both ends.
(#5625) Fibre Channel Cable
Summary: This feature supplies a multimode, 50.0 micron, 25.0 meter
fiber optic cable with LC plug connections at both ends.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 255.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of #5405, #5425, #5605, and #5625.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7301) SAN256N FICON CUP
The FICON CUP (Control Unit Port) feature supports in-band management
of the IBM TotalStorage SAN256N director by System Automation for OS/390
or z/OS on IBM 9672 Parallel Enterprise G5, G6 servers, and zSeries 900
and 990 servers. To enable in-band management on multiple directors,
each SAN256N will need to be configured with the FICON CUP feature
(#7301). This support provides a single point of control for managing
connectivity in active FICON I/O configurations. System Automation for
OS/390 or z/OS can now concurrently manage IBM 9032 ESCON Directors as
well as CNT Ultra-Net Multi-Service Directors and CNT FC/9000 Fibre
Channel Directors with FICON.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: When selected, you must order one unit of
#7301 for every four units of 16 port blades (#5316) ordered.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7302) SAN256N N16 FICON Cascading
The FICON Cascading feature (#7302) is required for cascading, or
creating FICON inter-switch links, between SAN256N directors with FICON
protocol applications. One feature (#7302) is needed per SAN256N
director to enable FICON Cascading between multiple directors in the same
fabric. This feature activates the firmware within the SAN256N necessary
to manage FICON configurations with up to two SAN256N directors (or a UMD
and FC/9000 Fibre Channel Director) between the FICON host server and the
FICON storage device. This feature enables further scalability of FICON
fabrics beyond the port count of a single SAN256N director. This feature
is optionally available for non-FICON, open systems Fibre Channel
environments where customers want the same degree of high integrity in
their fabric.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: When selected, you must order one unit of
#7302 for every four units of 16 port blades (#5316) ordered.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7303) SAN256N N16 SAN Services Bundle
The optional SAN Services Bundle consists of advanced SAN management
capabilities available for the UltraNet Multi-service Director. The
optional SAN Services Bundle enables activation of Logical Domains
partitioning functionality on the SAN256N.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: When selected, you must order one unit of
#7303 for every four units of 16 port blades (#5316) ordered.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7600) Enterprise Manager Server Bundle
Summary: This feature supplies a desktop PC running Windows 2000 and
includes: a 17-inch monitor, internal and external modems for call home
and remote diagnostics, and an 8-port Ethernet Hub with cables for
private LAN connections to up to 7 IBM TotalStorage SAN256N director
control modules.
For the Server Bundle, you must specify the appropriate Country Kit
(based on installation location), feature #9601-9662 with the IN-VSN
Enterprise Server Bundle. Features #9601-9662 will provide the
appropriate power cords, modem, phone line adapter, and appropriate
licenses.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: Must specify Country Kit feature #9601-#9662.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7603) Ethernet Hub - 8 ports
Summary: This feature supplies an additional 8-port Ethernet Hub. To
support the attachment of multiple SAN256N directors to the private LAN
of the IN-VSN Enterprise Manager Server PC, additional Ethernet ports may
be required. This feature enables you to order up to two additional
8-port Ethernet Hubs. The country unique power cords are provided with
the Management Server Bundle (#7600), no power cord will be supplied with
this feature.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7604) Ethernet Hub - 24 ports
Summary: This feature supplies an optional 24-Port hub, designed to
help manage multiple CNT Directors and reduce the need for multiple hubs.
This optional 24-Port hub may be used to connect with the current 8-Port
which is provided standard with the Enterprise Manager Server Bundle
(#7600).
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Cable Management for the SAN256N director
(#7640) Vertical Fiber Cable Management Set
This feature provides fiber cable management hardware which is
attached to the left and right sides of the SAN256N chassis in order
to facilitate more organized cabling. The vertical fiber cable
management set works in conjunction with horizontal fiber cable
management hardware already existing on each SAN256N chassis.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7645) Fiber Trunking Break-Out Box with Trunk Strain Relief
Summary: This feature provides four patch panel assemblies for
attachment to a single 2045-N16 chassis. Each patch panel provides
Multifiber Terminated Push-on (MTP) connector coupling between trunk
cables and patch cable bundles (refer to #7646-7651). Each panel
provides enough MTP couplers to cable to 64
Fibre Channel and associated monitoring ports plus several spare
couplers. Panels are labeled and hinged to provide easy access to both
sides of each coupler. Retention hardware to provide strain relief for
direct-attach trunk cables entering the UMD cabinet is included with
this feature.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7646) Single mode 64-Port Cable Bundle
Summary: This feature provides twelve
6-to-1 single mode cable assemblies for use with the Fiber Trunking
Break-out Patch Panel (#7645). Each assembly is terminated on
one end by a single MTP connector and on the other by six LC connectors.
The twelve assemblies are made up of different lengths to facilitate
more organized cabling. This bundle provides sufficient connections from
a patch panel for a single quadrant of 2045-N16 ports or, to 64 Fibre
Channel and associated monitoring ports. All the cables in this bundle
are 9/125 micron single mode fibers and are for use with single mode
direct-attach trunk cables. Individual cable assemblies are available
via features #7650 and #7651.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: Requires feature #7645.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7647) Multimode 64-Port Cable Bundle
Summary: This feature provides twelve 6-to-1 multimode cable
assemblies for use with the Fiber Trunking Break-out Patch Panel
(#7645). Each assembly is terminated on one end by a single MTP
connector and on the other by six LC connectors. The twelve assemblies
are made up of different lengths to facilitate more organized cabling.
This bundle provides sufficient connections from a
patch panel for a single quadrant of 2045-N16 ports, or to 64 Fibre
Channel and associated monitoring ports. All the cables in this bundle
are 50/125 micron multimode fibers and are for use with multimode
direct-attach trunk cables. Individual cable assemblies are available
via features #7650 and 7651.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: Four.
- Prerequisites: None.
- Corequisites: Requires feature #7645.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7650) Single mode 6-Port Cable Bundle
Summary: This feature provides an
individual 6-to-1 single mode cable assembly for use with the Fiber
Trunking Break-out Patch Panel (#7645). This cable is terminated
on one end by a single MTP connector and on the other by six LC
connectors. This cable provides a single MTP connection from a patch
panel to six Fibre Channel ports (LC connectors). The cable consists of
9/125 micron single mode fibers and is for use with single mode
direct-attach trunk cables. This feature is not a FRU.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 11.
- Prerequisites: None.
- Corequisites: Requires feature #7645.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7651) Multimode 6-Port Cable Bundle
Summary: This feature provides an
individual 6-to-1 multi-mode cable assembly for use with the Fiber
Trunking Break-out Patch Panel (#7645). This cable is terminated
on one end by a single MTP connector and on the other by six LC
connectors. This cable provides a single MTP connection from a patch
panel to six Fibre Channel ports (LC connectors). The cable consists of
50/125 micron multimode fibers and is for use with multimode
direct-attach trunk cables. This feature is not a FRU.
- Minimum Number of Features per 2045-N16: None.
- Maximum Number of Features per 2045-N16: 11.
- Prerequisites: None.
- Corequisites: Requires feature #7645.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
© IBM Corporation 2005.
Back to top
|
|
|
|