Description Machine Model Feature
----------------------------- ------- ----- -------
CNT FC/9000 FC Director 2042 001
2 Gb XFIO2 Modules (Initial build) 9222
Plant Install in 2042-C40 Cabinet 9204
Field Install in 2042-C40 Cabinet 9205
Country Kits:
U.S. 9601
Canada 9602
Mexico 9603
Argentina 9604
Brazil 9605
Chile 9606
Columbia 9607
Czech Republic 9635
Austria 9620
Belgium 9621
Denmark 9622
Finland, Norway 9623
France 9624
Germany 9625
Hungary 9636
Italy 9626
Liechtenstein 9627
Netherlands 9628
Portugal 9629
Russia 9630
Spain 9631
Sweden 9632
Switzerland 9633
United Kingdom, Ireland, Hong Kong 9634
South Africa 9637
Egypt 9638
Croatia, Slovenia 9639
Bulgaria, Poland 9640
Israel 9641
Greece 9642
Turkey 9643
Slovakia 9644
Saudi Arabia 9645
Romania 9646
Australia 9650
Japan 9651
New Zealand 9652
Peoples Republic of China 9653
Singapore 9654
South Korea 9655
Taiwan 9656
CNT FC/9000-128 FC Director 2042 128
Director
2 Gb XFIO2 Modules (Initial build) 9222
International Power 9150
North American Power 9160
Country Kits:
U.S. 9601
Canada 9602
Mexico 9603
Argentina 9604
Brazil 9605
Chile 9606
Columbia 9607
Czech Republic 9635
Austria 9620
Belgium 9621
Denmark 9622
Finland, Norway 9623
France 9624
Germany 9625
Hungary 9636
Italy 9626
Liechtenstein 9627
Netherlands 9628
Portugal 9629
Russia 9630
Spain 9631
Sweden 9632
Switzerland 9633
United Kingdom, Ireland, Hong Kong 9634
Egypt 9638
Croatia, Slovenia 9639
Israel 9641
Greece 9642
Turkey 9643
Slovakia 9644
Saudi Arabia 9645
Romania 9646
Australia 9650
Japan 9651
New Zealand 9652
Peoples Republic of China 9653
Singapore 9654
South Africa 9637
South Korea 9655
Taiwan 9656
CNT FC/9000 40U Cabinet 2042 C40
International Power 9150
North American Power 9160
Plant Install 2042-0001 in C40 Cabinet 9201
Cabinet Filler Panel 9202
Plant Install N16 into FC/9000 Model C40 Cabinet 9435
CNT FC/9000-256 FC Director 2042 256
2 Gb XFIO2 Modules (Initial build) 9222
North American Power 9160
Country Kits:
U.S. 9601
Canada 9602
Mexico 9603
Argentina 9604
Brazil 9605
Chile 9606
Columbia 9607
(#9222) 2 Gb XFIO2 Modules (Initial build only)
(No Longer Available as of December 31, 2004)
Summary: All new build machines are currently configured with 2 Gb
XFIO2 modules (equivalent to #5210), in the base assembly. Designate
this mandatory specify feature on all new build (IPO) orders.
For the 2042-001, there are two I/O modules included in the base
assembly. For the Model 128 there are three I/O modules included in the
base assembly. For the 2042-256, there are four I/O modules included in
the base assembly. Additional FIO or XFIO2 modules are available to fill
the remaining empty slots in the FC/9000 directors (see features #5010
and #5210).
- Minimum Number of Features per 2042-001: One.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: One.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: One.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Must order one #9222.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
Power Supply
Summary: You must specify the type of power required when ordering
CNT FC/9000-256 FC Director (2042-256), CNT FC/9000-128 FC
Director (2042-128) or the CNT FC/9000 40U Cabinet (2042-C40).
Specify the North American Power (#9160) for the United States,
Canada, or Mexico, and International Power (#9150) for all other
countries.
You must designate either feature number 9150 or 9160 in your initial
order. Power cords are included with the power supply.
(#9150) International Power
(No Longer Available as of December 31, 2004)
Specify this feature for countries requiring International Power.
This feature provides Cabinet power cords with IEC 60309 connector.
(#9160) North American Power
(No Longer Available as of December 31, 2004)
Specify this feature for North American Power requirements (United
States, Canada, Mexico). This feature provides Cabinet power cords with
NEMA L6-20P connector.
- Minimum Number of Features per 2042-C40: One.
- Maximum Number of Features per 2042-C40: One.
- Minimum Number of Features per 2042-128: One.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: One.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Select either #9150 or #9160.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO.
- Cable Order: None.
(#9601 - #9656) Country Kits
Summary: You must specify the specific Country Kit as a corequisite
of feature #7600, IN-VSN Enterprise Server Bundle. Specify the
appropriate Country Kit based on the installation location. Features
#9601-#9656 will provide the appropriate power cords, monitor, modem, and
phone line adapter, and appropriate licenses.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Corequisites: Required when ordering feature #7600
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
C40 Cabinet Installation Codes
The CNT FC/9000 40U Cabinet (C40) can contain one or two CNT FC/9000
Model 001 (2042-001), or CNT UltraNet Multi-service Directors (2042-N16).
Feature #9201, for Model 001, and #9235, for Model N16, will configure
the director into a new FC/9000 Model C40 Cabinet purchase.
For New C40 Order, must order #9201 = Min 1 Unit, or #9435 = Min 1
Unit (C40 must include at least one model 001 or one model N16).
(#9201) Plant Install Model 001 into CNT FC/9000 C40 Cabinet
(No Longer Available as of December 31, 2004)
Specify this feature in your initial order of the CNT FC/9000 Cabinet
to designate that the Model 001 FC/9000 Director will be plant installed
in a 2042-C40 Cabinet.
- Minimum Number of Features per 2042-C40: None.
- Maximum Number of Features per 2042-C40: Two.
- Prerequisites: None.
- Corequisites: Requires 2042-001 with #9204.
- Corequisites: Feature #9202 is required if only one 2042-001 is to
be installed in the 2042-C40 Cabinet.
- Compatibility Conflicts: Must have 2042-001 Director on same order.
- Compatibility Conflicts: Must specifiy either #9201 or #9435 on each
2042-C40 order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#9202) Cabinet Filler Panel
(No Longer Available as of December 31, 2004)
Specify this feature in your initial order to provide a Cabinet filler
panel for the unused (empty) section of the Cabinet to ensure proper air
flow. The feature is not required when two 2042-001 Directors are
installed in the Cabinet, 2042-C40 feature #9201.
- Minimum Number of Features per 2042-C40: None
- Maximum Number of Features per 2042-C40: One.
- Prerequisites: Feature #9201
- Corequisites: None.
- Compatibility Conflicts: Total of #9201 and #9202 must equal two.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No.
- Cable Order: None.
(#9204) Plant Install 2042-001 Director
(No Longer Available as of December 31, 2004)
Specify this feature in your initial order to designate if the FC/9000
Fibre Channel Director plant installed in a 2042-C40 Cabinet.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Cannot coexist with 9205
- Customer Setup: No.
- Limitations: None.
- Field Installable: No.
- Cable Order: None.
(#9205) Field Install 2042-001 Director
(No Longer Available as of August 26, 2005)
Specify this feature in your initial order to designate if the FC/9000
Fibre Channel Director 1 will be field installed in an existing 2042-C40
Cabinet.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: Cannot coexist with 9204
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes
- Cable Order: None
(#9435) Plant Install N16 into CNT FC/9000 C40 Cabinet
(No Longer Available as of December 31, 2004)
Specify this feature in your initial order of the CNT FC/9000 Cabinet
to designate that the CNT UltraNet Multi-service Director will be plant
installed in a 2042-C40 Cabinet.
- Minimum Number of Features per 2042-C40: None.
- Maximum Number of Features per 2042-C40: Two.
- Prerequisites: None.
- Corequisites: Requires 2042-N16 with #9431.
- Compatibility Conflicts: Must have 2042-N16 Director on same order.
- Compatibility Conflicts: Must specifiy either #9201 or #9435 on each
2042-C40 order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
Description Machine Model Feature
------------------------------- ------- ----- -------
CNT FC/9000 FC Director 2042 001
Shortwave GBIC 2010
Longwave GBIC 2020
Ext. Longwave GBIC (80 Km) 2030
Shortwave SFP Transceiver 2210
Longwave SFP Transceiver 2220
LW 35 Km SFP Transceiver 2235
LW 80 Km 2 Gbps SFP Transceiver 2280
CWDM Extended Distance Module 8-Port Mux 2308
CWDM Extended Distance Module 16-Port Mux 2316
1470 nm Wavelength Specific SFP 2321
1490 nm Wavelength Specific SFP 2322
1510 nm Wavelength Specific SFP 2323
1530 nm Wavelength Specific SFP 2324
1550 nm Wavelength Specific SFP 2325
1570 nm Wavelength Specific SFP 2326
1590 nm Wavelength Specific SFP 2327
1610 nm Wavelength Specific SFP 2328
Upgrade Model 001 to 256 capable 4001
Upgrade Model 001 HA to 256 capable 4002
Upgrade Model 128 to 256 capable 4008
Upgrade Model 128 HA to 256 capable 4009
Interconnect Kit for 128 port capability 4128
Advanced Interconnect Kit for 128-port capability 4129
Interconnect Kit for 256-port capability 4256
1 Gb FIO Module (8 ports) 5010
2 Gb XFIO2 Module (8 ports) 5210
FCME Upper (Replacement for 1 Gbps Directors) 5220
FCME Lower (Replacement for 1 Gbps Directors) 5221
High Availability Option 5020
5m, LC/LC Singlemode 9u Fiber Cable 5405
25m, LC/LC Singlemode 9u Fiber Cable 5425
5m, SC/SC Singlemode 9u Fiber Cable 5505
25m, SC/SC Singlemode 9u Fiber Cable 5525
5m, LC/LC Multimode 50u Fiber Cable 5605
25m, LC/LC Multimode 50u Fiber Cable 5625
SC/LC Coupling Kit, 50u 5701
SC/LC Coupling Kit, 9u 5703
4M SC/LC Single Mode, 4 meter Fiber Cable 5704
25M SC/LC Single Mode, 25 meter Fiber Cable 5705
4M SC/LC Multimode, 4 meter Fiber 5706
25M SC/LC MultiMode, 25 meter Fiber Cable 5707
FIO Slot Filler Modules 5910
Non-High Availability Filler Modules 5920
Additional IN-VSN Enterprise Manager Client 7201
FICON Management Server 7202
FICON Cascading Activation 7203
IN-VSN Enterprise Manager Server Bundle 7600
Ethernet Hub, 8 ports 7603
24-Port Hub 7604
PC Replacement Upgrade for EM Server 7610
512 MB Memory Card 7621
Advanced Remote Serviceability Kit 7625
Warranty Extension (2 Yrs) - 001 8001
Warranty Extension (3 Years) 8011
CNT FC/9000-128 FC Director 2042 128
Shortwave GBIC (multimode fibre) 2010
Longwave GBIC (single mode fibre) 2020
Ext. Longwave GBIC (80 Km) 2030
Shortwave SFP Transceiver 2210
Longwave SFP Transceiver 2220
LW 35 Km SFP Transceiver 2235
LW 80 Km 2 Gbps SFP Transceiver 2280
CWDM Extended Distance Module 8-Port Mux 2308
CWDM Extended Distance Module 16-Port Mux 2316
1470 nm Wavelength Specific SFP 2321
1490 nm Wavelength Specific SFP 2322
1510 nm Wavelength Specific SFP 2323
1530 nm Wavelength Specific SFP 2324
1550 nm Wavelength Specific SFP 2325
1570 nm Wavelength Specific SFP 2326
1590 nm Wavelength Specific SFP 2327
1610 nm Wavelength Specific SFP 2328
Upgrade Model 128 to 256 capable 4008
Upgrade Model 128 HA to 256 capable 4009
Interconnect Kit for 256-port capability 4256
Additional FIO Modules (8-ports) 5010
2 Gb XFIO2 Module (8 ports) 5210
FIO Slot Filler Modules 5910
HA Option/128 Port 5022
FCME Upper (Replacement for 1 Gbps Directors) 5220
FCME Lower (Replacement for 1 Gbps Directors) 5221
5m, LC/LC Singlemode 9u Fiber Cable 5405
25m, LC/LC Singlemode 9u Fiber Cable 5425
5m, SC/SC Singlemode 9u Fiber Cable 5505
25m, SC/SC Singlemode 9u Fiber Cable 5525
5m, LC/LC Multimode 50u Fiber Cable 5605
25m, LC/LC Multimode 50u Fiber Cable 5625
Fibre Optical Cable, 5 meter 5805
Fibre Optical Cable, 25 meter 5825
SC/LC Coupling Kit, 50u 5701
SC/LC Coupling Kit, 9u 5703
4M SC/LC Single Mode, 4 meter Fiber Cable 5704
25M SC/LC Single Mode, 25 meter Fiber Cable 5705
4M SC/LC Multimode, 4 meter Fiber 5706
25M SC/LC MultiMode, 25 meter Fiber Cable 5707
Non-HA Filler Mods/128 Port 5922
Additional IN-VSN Enterprise Manager Client 7201
FICON Management Server 7202
FICON Cascading Activation 7203
IN-VSN Enterprise Manager Server Bundle 7600
Ethernet Hub, 8 ports 7603
24-Port Hub 7604
PC Replacement Upgrade for EM Server 7610
512 MB Memory Card 7621
Advanced Remote Serviceability Kit 7625
Extended Warranty of CNT FC/9000 128
Port Director 8002
Warranty Extension (3 Years)- 128 8012
CNT FC/9000-256 FC Director 2042 256
Shortwave GBIC (multimode) 2010
Longwave GBIC (single mode) 2020
Ext. Longwave GBIC (80 Km) 2030
Shortwave SFP Transceiver 2210
Longwave SFP Transceiver 2220
LW 35 Km SFP Transceiver 2235
LW 80 Km 2 Gbps SFP Transceiver 2280
CWDM Extended Distance Module 8-Port Mux 2308
CWDM Extended Distance Module 16-Port Mux 2316
1470 nm Wavelength Specific SFP 2321
1490 nm Wavelength Specific SFP 2322
1510 nm Wavelength Specific SFP 2323
1530 nm Wavelength Specific SFP 2324
1550 nm Wavelength Specific SFP 2325
1570 nm Wavelength Specific SFP 2326
1590 nm Wavelength Specific SFP 2327
1610 nm Wavelength Specific SFP 2328
Additional FIO Modules (8-ports) 5010
2 Gb XFIO2 Module (8 ports) 5210
FCME Upper (Replacement for 1 Gbps Directors) 5220
FCME Lower (Replacement for 1 Gbps Directors) 5221
HA Option/256-Port 5224
5m, LC/LC Singlemode 9u Fiber Cable 5405
25m, LC/LC Singlemode 9u Fiber Cable 5425
5m, SC/SC Singlemode 9u Fiber Cable 5505
25m, SC/SC Singlemode 9u Fiber Cable 5525
5m, LC/LC Multimode 50u Fiber Cable 5605
25m, LC/LC Multimode 50u Fiber Cable 5625
Fibre Optical Cable, 5 meter 5805
Fibre Optical Cable, 25 meter 5825
SC/LC Coupling Kit, 50u 5701
SC/LC Coupling Kit, 9u 5703
4M SC/LC Single Mode, 4 meter Fiber Cable 5704
25M SC/LC Single Mode, 25 meter Fiber Cable 5705
4M SC/LC Multimode, 4 meter Fiber 5706
25M SC/LC MultiMode, 25 meter Fiber Cable 5707
FIO Slot Filler Modules 5910
Non-HA Filler Mods/256-Port 5924
Additional IN-VSN Enterprise Manager Client 7201
FICON Management Server 7202
FICON Cascading Activation 7203
IN-VSN Enterprise Manager Server Bundle 7600
Ethernet Hub, 8-ports 7603
24-Port Hub 7604
PC Replacement Upgrade for EM Server 7610
512 MB Memory Card 7621
Advanced Remote Serviceability Kit 7625
Warranty Extension (2 Years)- 256 8003
Warranty Extension (3 Years)- 256 8013
CNT FC/9000 Cabinet 2042 C40
C40 Cabinet North America 7800
C40 Cabinet International 7801
(#4001) Upgrade Model 001 to 256-Port Capable
(No Longer Available as of September 30, 2005)
Summary: This feature provides upgrade hardware necessary for the
Model 001 (FC/9000-64) to be able to be scaled to a 256-port and 2Gb
ready configuration. This feature provides two new Switch Modules, a new
control module, and new appropriate filler panels. When upgrading a
Model 001 that is not HA (does not have feature #5020) to 2Gb or 256-port
Director capability, this feature is mandatory.
(#4002) Upgrade Model 001/HA to 256-Port Capable
(No Longer Available as of September 30, 2005)
Summary: This feature provides upgrade hardware necessary for the
Model 001 (FC/9000-64), with High Availability installed, to be able to
be scaled to a 256-port and 2Gb ready configuration. This feature
provides three new Switch Modules, two new control modules, and new
appropriate filler panels. When upgrading a Model 001 that has HA
(feature #5020) to 2Gb or 256-port Director capability, this feature is
mandatory.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: Feature #5020 is required for feature #4002; features
#5020 and #4001 are mutually exclusive.
- Corequisites: None.
- Compatibility Conflicts: Select either #4001 or #4002.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, MES only.
- Cable Order: None.
(#4008) Upgrade Model 001 or 128 to 256-Port Capable
(No Longer Available as of September 30, 2005)
Summary: This feature provides upgrade hardware necessary for the
Model 128 (FC/9000-128) to be able to be scaled to a 256-port and 2Gb
ready configuration. This feature can also be used if interconnecting
two original hardware Model 001s (FC/9000-64), and eliminates using
feature #4128. This feature provides four new Switch Modules, two new
control modules, and new appropriate filler panels. When upgrading a
Model 128, or two original hardware Model 001s that are not HA (does not
have feature #5022) to 2Gb or 256-port Director capability, this feature
is mandatory.
(#4009) Upgrade Model 001/HA or 128/HA to 256-Port Capable
(No Longer Available as of September 30, 2005)
Summary: This feature provides upgrade hardware necessary for the
Model 128 (FC/9000-128), with High Availability installed, to be able to
be scaled to a 256-port and 2Gb ready configuration. This feature can
also be used if interconnecting two original hardware Model 001s
(FC/9000-64), and eliminates using feature #4128. This feature provides
five new Switch Modules, four new control modules, and new appropriate
filler panels. When upgrading a Model 128 that has HA (feature #5022),
or two original hardware Model 001s that have HA (feature #5020) to 2Gb
or 256-port Director capability, this feature is mandatory.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Prerequisites: For the Model 001, Feature #5020 or #5022 is required
for feature #4009; features #5020 and #4008 are mutually exclusive. For
the Model 128, feature #5022 is required for feature #4009; features
#5022 and #4008 are mutually exclusive.
- Corequisites: None.
- Compatibility Conflicts: Select either #4008 or #4009.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, MES only.
- Cable Order: None.
(#4128) Interconnect Kit for 128 port Capability
(No Longer Available as of September 30, 2005)
Summary: This feature provide the hardware and firmware necessary to
interconnect two 64 port FC/9000 Directors installed in the same 40U
Cabinet to operate as a 128 port Director. Included are interconnect
cables, FC/9000 firmware upgrade to 128 port capability, and IN-VSN
Management Server upgrade to 128 port capability. Two 64 port FC/9000
Directors interconnected with this feature are functionally equivalent to
the Model-128, the 128 port FC/9000 Director. The installation of this
feature is a disruptive install.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: Must have two 64 port FC/9000 Directors (2042-001)
installed in the same 40U Cabinet (2042-C40). This feature can be
ordered on a second 64 port Director (2042-001) with specify feature
#9205 for Field Installation.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#4129) Interconnect Kit for 128-port Capability
(No Longer Available as of September 30, 2005)
Summary: This feature provide the hardware and firmware necessary to
interconnect two new hardware 64-port FC/9000 Directors installed in the
same 40U Cabinet to operate as a 128-port Director. Included are
interconnect cables, FC/9000 firmware upgrade to 128-port capability, and
IN-VSN Management Server upgrade to 128-port capability. Two 64-port
FC/9000 Directors interconnected with this feature are functionally
equivalent to the Model 128, the 128-port FC/9000 Director. The
installation of this feature is a disruptive install.
Note: #4129 is designed to interconnect two 64-port Directors that have
the upgraded 256-port/2Gb ready (new hardware) hardware installed.
Original hardware 64-port Directors being interconnected require either
feature #4128 and remain at the original hardware, or features #4008/4009
which provide upgrade to new hardware and the interconnection kit. New
hardware 64-port Directors, do not require #4001/4002 upgrade as it is
included in the base configuration of the Model 001.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: Must have two 64-port FC/9000 Directors (2042-001)
installed in the same 40U Cabinet (2042-C40). This feature can be
ordered on a second 64-port Director (2042-001) with specify feature
#9205 for Field Installation.
- Corequisites: None.
- Compatibility Conflicts: Select feature #4128, or #4008/4009 if old
hardware Model 001s.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#4256) Interconnect Kit for 256-port Capability
(No Longer Available as of September 30, 2005)
Summary: This feature provides the hardware and firmware necessary to
interconnect two 128-port FC/9000 Directors that have the upgraded
256-port hardware (new hardware) installed and in two adjacent 40U
Cabinets to operate as a 256-port Director. Included are interconnect
cables, FC/9000 firmware upgrade to 256-port capability, and IN-VSN
Management Server upgrade to 256-port capability. Two 128-port FC/9000
Directors interconnected with this feature are functionally equivalent to
the Model 256, the 256-port FC/9000 Director. The installation of this
feature is a disruptive install.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Prerequisites: Must have two 128-port FC/9000 Directors, either:
- Two adjacent Model 128s; that have the new hardware installed (see
features 4008/4009); or
- Four Model 001s installed in two adjacent FC/9000 Cabinets (2042-C40)
that have the new hardware installed (see features #4001/4002 or
4008/4009), and are interconnected (see feature #4008/4009 or
#4128/4129); or
- One Model 128 that has the new hardware installed and an adjacent
FC/9000 Cabinet (#2042-C40) with two MODEL 001s feature #2042-001s that
are interconnected and have the new hardware installed.
- Corequisites: None.
- Compatibility Conflicts: This feature can be ordered on either one
of the 64-port Directors (#2042-001), or on one of the Model 128s for
field installation (MES). Only one feature #4256 is required.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
2 Gb and 1 Gb Configuration Options
The CNT FC/9000 Fibre Channel Director allows a wide range of
configuration options and can be ordered with combinations of 2 Gb XFIO2
or 1 Gb FIO Modules. The basic building block is the I/O Module which
contains eight Fibre Channel ports, and is available with 2 Gb or 1 Gb
technology. New built base CNT FC/9000 Directors are configured with
the 2 Gb XFIO2 Modules. Growth to the maximum port counts is available
with either 2 Gb XFIO2 or 1 Gb FIO Modules.
- Model 001, you can add from one to six additional 8-port FIO Modules
(#5010), XFIO2 Modules (#5210), and/or Filler Modules (#5910) in any
combination for a maximum of 64-ports.
- Model 128, you can add from one to 13 additional 8-port FIO Modules
(#5010), XFIO2 Modules (#5210), and/or Filler Modules (#5910) in any
combination for a maximum of 128 ports.
- Model 256, you can add from one to 28 additional 8-port FIO Modules
(#5010), XFIO2 Modules (#5210), and/or Filler Modules (#5910) in any
combination for a maximum of 256 ports.
The 2 Gb XFIO2 Module (#5210) supports autosensing, and will operate
as either a 2 Gb port or 1 Gb port depending on the attaching device
capabilities. Autosensing enables the 2 Gb XFIO2 module to support both
1 Gb and 2 Gb fabric devices. The 2 Gb XFIO2 Modules can be configured
with either shortwave (#2210) or longwave (#2220) SFP transceivers, or
for distances up to 35 Km or 80 Km, with
the Extended Distance Longwave 2 Gb SFP transceivers (#2235 or #2280).
The 1 Gb FIO Module (#5010) supports 1 Gb fabric, 1 Gb public loop
(FC-AL), and 1 Gb private loop devices. The 1 Gb FIO Module is a
necessary component to include attachment of 1 Gb FC-AL devices, such as
IBM 3590 and LTO tape products. The 1 Gb FIO Modules can be configured
with either shortwave (#2010) or longwave (#2020) GBICs, or for distances
up to 80 Km with the Extended Longwave GBIC (#2030).
Intermix of 2 Gb XFIO2 and 1 Gb FIO Modules in a FC/9000 Director
enables support of both 1 Gb and 2 Gb fabric devices, as well as 1 Gb
loop devices.
Any mixture of shortwave and longwave configured ports are supported,
but all ports must have transceivers or GBICs ordered. Transceivers and
GBICs must be ordered in increments of 8, either eight shortwave, eight
longwave or a mix of shortwave and longwave.
I/O Modules
(#5010) Additional FIO Modules (8-ports)
Summary: This feature supplies an additional 8-port FIO Module. You
may designate in your initial order the maximum per model of FIO Modules
(#5010), and/or Filler Modules (#5910) in any combination.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Six.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 13.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 28.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Max. is total of #5010, #5210, and #5910 on initial
order.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5210) Additional 2 Gb XFIO2 Module
Summary: This feature supplies an additional 8-port XFIO2 Module.
When ordering additional XFIO2 modules for field (MES) installation,
the maximum MES quantity will allow you to remove and replace existing
FIO modules (#5010) in the base configuration. Ordering the maximum MES
quantity is only necessary for CNT Directors whose initial machine
build included the FIO (#5010 equivalent) modules in the base assembly.
This feature may only be ordered for a 2042 that is "New Version
Hardware/2 Gb capable".
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Six.
- Maximum Number of MES Features per 2042-001: Eight.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 13.
- Maximum Number of MES Features per 2042-128: 16.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 28.
- Maximum Number of MES Features per 2042-256: 32.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: 2042 must be "New Version Hardware/2 Gb
capable".
- Customer Setup: No.
- Limitations: Max. is total of #5010, #5210, and #5910 on initial
order.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5910) FIO/XFIO2 Slot Filler Modules
(No Longer Available as of December 31, 2004)
Summary: This feature supplies a filler module for the unused (empty)
FIO/XFIO2 slots to ensure proper air flow. Unused (empty) FIO/XFIO2
slots must have a filler.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Six.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 13.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 28.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Max. is total of #5010, #5210, and #5910 on initial
order.
- Field Installable: No, IPO.
- Cable Order: None.
Gigabit Interface Converters
Summary: The 1 Gb FIO Modules (#5010) can be configured with either
shortwave (#2010) or longwave (#2020) GBICs, or for distances up to 80 Km
with the Extended Longwave GBIC (#2030). Any combination of shortwave
and longwave GBICs can be configured on a FIO module. All ports on the
FIO modules must have a GBIC ordered. GBICs are ordered in increments of
8, either eight shortwave, eight longwave, or a mix of shortwave and
longwave based on the number of FIO modules ordered.
(#2010) Shortwave GBIC
Summary: This feature supplies a shortwave GBIC allowing Fibre
Channel connections of up to 500 meters (.31 miles).
(#2020) Longwave GBIC
Summary: This feature supplies a longwave GBIC allowing Fibre Channel
connections of up to 10.0 Km (6.2 miles).
(#2030) Extended Longwave GBIC
Summary: This feature supplies an extended longwave GBIC allowing
FC/9000 Director-to FC/9000 Director connections of up to 80.0 Km (49.6
miles). Both FC/9000 Directors must use the Extended Longwave GBIC for
an interconnection at extended distances.
- Minimum Number of Features per 2042-001: 0
- Maximum Number of Features per 2042-001: 48, in increments of 8
- Minimum Number of Features per 2042-128: 0
- Maximum Number of Features per 2042-128: 104, in increments of 8
- Minimum Number of Features per 2042-256: 0
- Maximum Number of Features per 2042-256: 224, in increments of 8
- Prerequisites: None.
- Corequisites: Feature #5010 is required for each 8 additional GBICs
over the minimum ordered.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Max is total of features #2010, #2020, and #2030.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
SFP Transceivers
Summary: The 2 Gb XFIO2 Modules can be configured with either
shortwave (#2210) or longwave (#2220) SFP transceivers, or for distances
up to 35 Km or 80 Km, with the Extended Distance Longwave 2 Gb SFP
tranceivers (#2235 or #2280). Any
combination of shortwave and longwave transceivers can be configured on a
XFIO2 module. All ports on the XFIO2 modules must have a transceiver
ordered. Transceivers are ordered in increments of 8, either eight
shortwave, eight longwave, or a mix of shortwave and longwave based on
the number of XFIO2 modules ordered.
Note: Feature #9222 indicates that the base FC/9000 Director is built
with 2 Gb XFIO2 Modules, in which case, SFP Transceivers (#2210, #2220,
#2235, or #2280) are required. GBICs (#2010, #2020 and #2030) are used
only with FIO Modules.
(#2210) Shortwave SFP Transceiver
Summary: This feature supplies one shortwave optical SFP transceiver
that autosenses to operate at either 2 Gb (for connections up to 300
meters), or 1 Gb (for connections up to 500 meters) dependent on the
attaching device.
(#2220) Longwave SFP Transceiver
Summary: This feature supplies one longwave optical SFP transceiver
that autosenses to operate at either 2 Gb, or 1 Gb for connections up
to 10 Km.
(#2235) Extended Distance 35 Km Longwave 2 GB SFP
The Extended Distance 35 Km Longwave 2 GB SFP option is designed to
provide extended distance up to 35 Km between supported devices, while
operating at 2 Gpbs. Dedicated port buffer credits within the CNT
FC/9000 Family are designed to work with the 35 Km longwave 2 Gb SFP
to help users extend FCP and FICON Inter Switch Links (ISL)s up to 35 Km
distance, in campus environments or metropolitan area networks. The 35
Km longwave 2 GB SFP is designed to be hot pluggable for use in any port
on the XFIO2 module (#5210).
- Minimum Number of Features per 2042-001: 16
- Maximum Number of Features per 2042-001: 64, in increments of 8
- Minimum Number of Features per 2042-128: 24
- Maximum Number of Features per 2042-128: 128, in increments of 8
- Minimum Number of Features per 2042-256: 32
- Maximum Number of Features per 2042-256: 256(1), in increments of 8
- Prerequisites: None.
- Corequisites: Feature #5210 is required for each 8 additional
Transceivers over the minimum ordered. Minimums apply only if feature
#9222 is specified on the initial order. For MES orders, the minimums
are zero.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Max is total of features #2210, #2220, and #2235.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#2280) Extended Distance 80 Km Longwave 2 GB SFP
Summary: The Extended Distance 80 Km Longwave 2 Gigabit SFP option
is designed to provide (up to 80 Km) Inter-Switch Links (ISLs) between
FC/9000 Directors while operating at 2 Gbps, depending upon optical
cable quality of the customer-provided dark fiber cable plant. The 80
Km Longwave 2 Gigabit SFP is designed to be hot pluggable for use in
any port on the XFIO2 Blade (FC#5210). XFIO2 Blades support both
shortwave and longwave SFP transceivers on the same blade.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: 64, in increments of 8
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 128, in increments of 8
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 256*, in increments of 8
- Prerequisites: None.
- Corequisites: Feature #5210 is required for each 8 additional
transceivers over the minimum ordered. Minimums apply only if feature
#9222 is specified on the initial order. For MES orders, the minimums
are zero.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Max total is for features #2210, #2220, #2235, and
#2280.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Note: (1)Due to AAS order entry limitations the maximum quantity that can
be ordered of any specific feature number is 255. When you wish to order
the maximum capacity of 256 of a specific feature (ie; #2210, Quantity =
256) enter into AAS a quantity of 255, CNT will fulfill the order for
the complete 256 transceivers. This limitation applies to both plant
(IPO) and Field (MES) ordering. This limitation does not affect mixed
GBIC ordering (ie: #2210, Qty = 128, and #2220, Qty = 128), in this case
the maximum quantity can be ordered in AAS.
CWDM Extended Distance Modules
(#2308) CWDM Extended Distance Module 8-Port Mux
(#2316) CWDM Extended Distance Module 16-Port Mux
Summary: The CNT Coarse Wave Division Multiplex (CWDM) extended
distance support option is available in an 8-Port Mux or 16-Port Mux
module. The CNT CWDM option is designed to support fiber optic cable
consolidation for applications with large numbers of Inter-Switch Links
(ISL)s routed between remotely located FC/9000 Directors. Physically,
it aggregates eight fiber cable pairs into a single fiber cable pair
between remote FC/9000 Director sites. Depending upon optical cable
quality of the customer-provided dark fiber cable plant, the CNT CWDM
extended distance support option is designed to provide up to 60 Km
ISLs between FC/9000 Directors while operating at 2 Gbps. When ordering
the 8-Port Mux or 16-Port Mux module, you must purchase at least one CWDM
wavelength specific SFP (#2321 through #2328).
The CNT Coarse Wave Division Multiplex (CWDM) extended distance
support option utilizes eight different wavelength specific SFPs, which
are designed for use on the XFIO2 Blade (#5210), which accepts SFP
transceivers. A single mode fiber optic cable (#5405) is used to make
connection between the CWDM wavelength specific SFP and port on the
8-Port Mux or 16-Port Mux module.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Two.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: Five
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: Eight.
- Prerequisites: None.
- Corequisites: Must buy at least one wavelength specific SFP (#2321
through #2328).
- Corequisites: Max per Model is total of #2308 and #2316.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For use only with XFIO2 Modules (#5210) which accepts
SFPs.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#2321 - #2328) Wavelength Specific SFPs
Summary: The CNT Coarse Wave Division Multiplex (CWDM) extended
distance support option utilizes eight different wavelength specific
SFPs, which are designed for use on the XFIO2 Blade (#5210), which
accepts SFP transceivers. A single mode fiber optic cable (#5405) is
used to make connection between the CWDM Wavelength Specific SFP and
port on the 8-Port Mux Module (#2308) or 16-Port Mux Module (#2316).
Depending upon optical cable quality of the customer provided dark fiber
cable plant, the CNT CWDM extended distance support option is designed
to provide up to 60 Km ISLs between FC/9000 Directors while operating
a 2 Gbps.
- (#2321) 1470 nm Wavelength Specific SFP
- (#2322) 1490 nm Wavelength Specific SFP
- (#2323) 1510 nm Wavelength Specific SFP
- (#2324) 1530 nm Wavelength Specific SFP
- (#2325) 1550 nm Wavelength Specific SFP
- (#2326) 1570 nm Wavelength Specific SFP
- (#2327) 1590 nm Wavelength Specific SFP
- (#2328) 1610 nm Wavelength Specific SFP
- Minimum Number of each Feature per 2042-001: None.
- Maximum Number of each Feature per 2042-001: Four.
- Minimum Number of each Feature per 2042-128: None.
- Maximum Number of each Feature per 2042-128: Ten.
- Minimum Number of each Feature per 2042-256: None.
- Maximum Number of each Feature per 2042-256: Sixteen.
- Prerequisites: Must already have #2308 or #2316.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For use only with XFIO2 Modules (#5210) which accepts
SFPs.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
High Availability Options
(#5020) High Availability Option/64 Port
Summary: This feature provides a second Fabric Switch Module, second
Fibre Controller Module, and a second Power Module (providing redundant
power supplies). You must designate in your initial order either feature
#5020 or #5920.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5020 and #5920 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#5022) High Availability Option/128 Port
Summary: This feature supplies a second Fabric Switch Module, second
Fibre Controller Module, and a second Power Module (providing redundant
power supplies) for the Model 128. You must designate in your initial
order either feature #5022 or #5922.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5022 and #5922 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes.
- Cable Order: None.
(#5220 - #5221) CNT upgrades for 1 Gbps Directors
Summary: The CNT upgrade support option for 1 Gigabit fabric
Directors provides the means to replace existing FC/9000 Control Module
(FCM) blades with FC/9000 Control Module Enhanced (FCME) blades, and add
support for firmware release 4.3 enhanced functions on 1 Gigabit fabric
Directors. In order to operate at 2 Gigabit speeds as well as upgrade
to release 4.3, you must separately purchase the 2 Gbps upgrade package.
(#5220) FCME Upper (Replacement For 1GB/S Directors)
(#5221) FCME Lower (Replacement For 1GB/S Directors)
- Minimum Number of each Features per 2042-001: None.
- Maximum Number of each Features per 2042-001: One.
- Minimum Number of each Features per 2042-128: None.
- Maximum Number of each Features per 2042-128: Two.
- Minimum Number of each Features per 2042-256: None.
- Maximum Number of each Features per 2042-256: Four.
- Prerequisites: For #5221, must already have same number of #5220.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, MES Only.
- Cable Order: None.
(#5224) High Availability Option/256-Port
Summary: This feature supplies a second Fabric Switch Module, second
Fibre Controller Module, and a second Power Module (providing redundant
power supplies) for the Model 256. You must designate in your initial
order either feature #5224 or #5924.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5224 and #5924 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#5920) Non-High Availability Filler Modules
(No Longer Available as of August 26, 2005)
This feature provides the filler module for the unused (empty) HA
slots to ensure proper air flow. You must order either feature #5020 or
5920.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5020 and #5920 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No.
- Cable Order: None.
(#5922) Non-High Availability Filler Modules/128 Port
(No Longer Available as of December 31, 2004)
Summary: This feature supplies the filler modules for the unused
(empty) HA slots to ensure proper air flow for the Model 128. You must
order either feature #5022 or 5922.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5022 and #5922 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No.
- Cable Order: None.
(#5924) Non-High Availability Filler Modules/256-Port
(No Longer Available as of December 31, 2004)
Summary: This feature supplies the filler modules for the unused
(empty) HA slots to ensure proper air flow for the Model 256. You must
order either feature #5224 or 5924.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #5224 and #5924 cannot coexist on the
initial order.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO.
- Cable Order: None.
Fiber Optic Cables
A fiber optic cable is required for attaching the 2042 FC/9000 FC
Director's port Transceiver/GBIC to the host system adapters, a fibre
channel storage subsystem, or another fibre channel SAN component. Fibre
optical cables are customer supplied to enable maximum flexibility and
compatibility in various environments, but where a limited distance
connection exists, fiber optic cables can be ordered with the CNT
products from IBM.
In many situations, the lengths and installation of fiber optic cables
required will be unique to each customer's configuration and facility
specifications. Product support services offered by IBM Global Services'
Site and Connectivity Solutions can provide assistance for these unique
cabling and installation requirements.
For situations where the Fibre Channel Directors and attaching
subsystems are within twenty-five meters, there are features to
accommodate these simple installations. Each feature provides either a
multimode 50.0/125 micrometer or a singlemode 9.0/125 micrometer fiber
optic cable in the available length with duplex SC connectors at both
ends. Customer supplied fiber optic cables for shortwave connections
must be multimode 50.0/125 micrometers for distances up to 500 meters at
1Gb, or multimode 62.5/125 micrometers for distances up to 175 meters at
1Gb; for longwave connections the fiber cable must be singlemode 9.0/125
micrometers for distances up to 10 kilometers.
(#5405) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 5.0 meter
fiber optic cable with LC plug connections at both ends.
(#5425) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 25.0 meter
fiber optic cable with LC plug connections at both ends.
(#5505) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 5.0 meter
fiber optic cable with SC plug connections at both ends.
(#5525) Fibre Channel Cable
Summary: This feature supplies a single mode, 9.0 micron, 25.0 meter
fiber optic cable with SC plug connections at both ends.
(#5605) Fibre Channel Cable
Summary: This feature supplies a multimode, 50.0 micron, 5.0 meter
fiber optic cable with LC plug connections at both ends.
(#5625) Fibre Channel Cable
Summary: This feature supplies a multimode, 50.0 micron, 25.0 meter
fiber optic cable with LC plug connections at both ends.
(#5805) Fiber Channel Cable
Summary: This feature supplies a multimode optical 50.0 micron cable,
5.0 meters fiber optic cable with SC plug connections at both ends.
(#5825) Fiber Channel Cable
Summary: This feature supplies a multimode optical 50.0 micron cable,
25.0 meters fiber optic cable with SC plug connections at both ends.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: 64
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 128
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 256
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
New fiber optic convenience cables are added to assist connection
between SC and LC fiber optic connector assemblies:
(#5704) 4M SC/LC Single Mode, 4 meter Fiber Cable
Summary: This feature supplies a single mode, 9.0 micron, 4.0 meter
fiber optic cable with a male SC and male LC plug connection at each end.
(#5705) 25M SC/LC Single Mode, 25 meter Fiber Cable
Summary: This feature supplies a single mode, 9.0 micron, 25.0 meter
fiber optic cable with a male SC and male LC plug connection at each end.
(#5706) 4M SC/LC Multimode, 4 meter Fiber
Summary: This feature supplies a multimode, 50.0 micron, 4.0 meter
fiber optic cable with a male SC and male LC plug connection at each end.
(#5707) 25M SC/LC Multimode, 25 meter Fiber Cable
Summary: This feature supplies a multimode, 50.0 micron, 25.0 meter
fiber optic cable with a male SC and male LC plug connection at each end.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: 64.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 128.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 256.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Coupling Cables
(#5701) SC/LC Coupling Kit, 50u
Summary: This feature supplies a coupling kit for multimode, 50.0
micron, fiber optic cable. The kit includes:
- One duplex SC (female)/SC (female) coupler
- One duplex LC (female)/LC (female) coupler
- One four-meter fiber optic cable with an SC (male) connector on one
end and an LC (male) connector on the other.
(#5703) SC/LC Coupling Kit, 9u
Summary: This feature supplies a coupling kit for singlemode, 9.0
micron, fiber optic cable. The kit includes:
- One duplex SC (female)/SC (female) coupler
- One duplex LC (female)/LC (female) coupler
- One four-meter fiber optic cable with an SC (male) connector on one
end and an LC (male) connector on the other.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: 64
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 128
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: 256
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Maximum is the total number of #5701 and #5703.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Product Support Services offered by IBM Global Services can provide
additional fiber optic components, and fiber optic cabling solutions.
IBM Site and Connectivity Services (IT Consulting and Implementation
Services in the U.S.) provides structured, modular, fiber optic data
center connectivity solutions as part of its Fiber Transport Services
(FTS) offering. Preterminated fiber optic trunk cables in standard
lengths up to 138 m (450 ft) and fiber optic jumper cables in lengths up
to 61 m (200 ft) are available as part of the planing, fiber optic
commodities, and installation activities performed by IBM personnel.
Custom lengths and custom installation of fiber optic cables, both
multimode and single mode, can also be provided as part of IBM Site and
Connectivity Services' solutions. Contact your local IBM Services Sales
Specialist for additional information on Fiber Transport Services or IBM
Site and Connectivity Services. In the United States, call
1-800-IBM-4YOU, or contact Matt Matthews at 770-863-2326 (tie line
753-2326).
Additional information can also be found at:
http://www.as.ibm.com/asus/connectivity.html
(#7201) Additional IN-VSN Enterprise Manager Client
Summary: This feature supplies additional IN-VSN Client software for
additional Windows NT or Windows 2000 workstation interfaces to the
IN-VSN Management Server.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: 16.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: 16.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7202) FICON Management Server
Summary: This feature supplies additional code within the CNT
FC/9000 Fibre Channel Director to support in-band management of the
Director by System Automation for OS/390 and zSeries 900 and 800 Servers.
System Automation OS/390 provides a single point of control for managing
connectivity in active I/O configurations. It takes an active role in
detecting unusual I/O conditions and lets a customer view and change
paths between a processor and an Input/Output device using the dynamic
switching capability of the FC/9000 FC Directors. This type of dynamic
in-band management is currently in the 9032 ESCON Directors.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7203) FICON Cascading Activation
Summary: This feature supplies the firmware activation to enable
FC/9000 Directors to be cascaded in FICON protocol applications. The
FC/9000 Director must be upgraded to new version hardware (256-port
capable and 2Gb ready) and at firmware level 3.2.2 or later for this
capability.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: Firmware at level 3.2.2 or later
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7600) IN-VSN Enterprise Manager Server Bundle
Summary: This feature supplies a desktop PC running Windows 2000 and
includes: a monitor, one gigabit memory, internal and external modems
for call home and remote diagnostics, and an 24-port Ethernet Hub with
cables for private LAN connections to FC/9000 FC Directors Control
Modules.
For the Server Bundle, you must specify the appropriate Country Kit
(based ion installation location), feature #9601-9656 with the IN-VSN
Enterprise Server Bundle. Features #9601-9656 will provide the
appropriate power cords, modem, phone line adapter, and appropriate
licenses.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: Must specify Country Kit feature #9601-#9656
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7603) Ethernet Hub, 8-ports
(No Longer Available as of August 26, 2005)
Summary: This feature supplies an additional 8-port Ethernet Hub. To
support the attachment of multiple FC/9000 Directors to the private LAN
of the IN-VSN Enterprise Manager Server PC, additional Ethernet ports may
be required. This feature enables you to order up to two additional
8-port Ethernet Hubs. The country unique power cords are provided with
the Management Server Bundle (#7600), no power cord will be supplied with
this feature.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Two.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: Two.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes. MES only.
- Cable Order: None.
CNT Management Support Options
CNT management support options are designed to enhance management
of installations including large fabrics and multiple directors. New
management support options include a new 24-Port Hub, PC Replacement
Upgrade For IN-VSN Enterprise Manager (EM) Server, 512 MB memory upgrade
for EM Server, and Advanced Remote Serviceability Kit upgrade for EM
Server.
(#7604) 24-Port Hub
Summary: This feature supplies an optional 24-Port hub, designed to
help manage multiple CNT Directors and reduce the need for multiple
hubs. This optional 24-Port hub may be used to connect with the current
8-Port hub, which is provided standard with the FC/9000 Enterprise
Manager (#7600).
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7610) PC Replacement Upgrade for EM Server
Summary: This feature supplies an optional PC Replacement Upgrade for
Enterprise Managers (EM) Server, to assist customers with older model
Enterprise Managers, who find their current PC may not support additional
memory capacity. It is not necessary to purchase any software with this
option. The optional PC Replacement Upgrade is provided as Field
Installable (MES) only, for customers with an existing FC/9000
installation. New plant orders should purchase the standard FC/9000
server (#7600), which accommodates additional memory capacity. The
optional PC Replacement Upgrade for EM Server includes the following
items:
- PC with 1 GB memory
- Monitor, Keyboard, Mouse
- NIC card
- Internal modem
For further information on CNT EM Server configurations and
guidelines regarding potential PC Replacement Upgrade, refer to the IBM
page in the following CNT Alliance support web site:
http://www.cnt.com/alliances
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, MES Only.
- Cable Order: None.
(#7621) 512 MB Memory Card
Summary: This optional feature is provided to increase the amount of
memory installed in a single Enterprise Manager Server, to help support
management of multiple 256-port FC/9000 Directors. The following provide
the recommended total memory for installation into a single EM Server, to
support the corresponding number of ports and 256-port Directors.
Number Number of Total Memory
Of Ports 256-port Directors Required for EM
-------- ------------------ ---------------
256 (1) FC/9000-256 256 MB
768 (3) FC/9000-256 512 MB
1536 (6) FC/9000-256 1024 MB
For further information on CNT EM Server configurations and
guidelines regarding memory capacity, refer to the IBM page in the
following CNT Alliance support web site:
http://www.cnt.com/alliances
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Two.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: Two.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(#7625) Advanced Remote Serviceability Kit
Summary: This feature supplies an optional Advanced Remote
Serviceability Kit designed to assist service representatives to
troubleshoot and diagnose problems remotely. This optional feature is
designed to benefit customers by helping to restore the system more
rapidly and reduce the need for potential service calls. The Advanced
Remote Serviceability Option is designed to operate in any Enterprise
Manager Server having the latest version of Enterprise Manager software
installed, and having an available PCI slot to support the Serial
Ethernet Quad-Port Card. The optional Advanced Remote Serviceability Kit
includes the following items:
- Serial Ethernet Quad-Port Card for the Enterprise Manager
- Crossover Cables
- Ethernet Cables
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Features for 2042-C40 FC/9000 Cabinet
(#7800) C40 Cabinet North America Shipping for CNT N16
(No Longer Available as of December 31, 2004)
Specify this feature for North American shipping requirements (United
States, Canada, Mexico).
- Minimum Number of Features per 2042-C40: None.
- Maximum Number of Features per 2042-C40: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
(#7801) C40 Cabinet International Shipping for CNT N16
(No Longer Available as of December 31, 2004)
Specify this feature for countries requiring International shipping
requirements.
- Minimum Number of Features per 2042-C40: None.
- Maximum Number of Features per 2042-C40: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: No, IPO only.
- Cable Order: None.
Warranty Extensions
All warranties for this product are provided by CNT Technologies.
The current warranty for the CNT FC/9000 Fibre Channel Directors is
24 hours per day/7 days per week, same day service support for 13 months
from the date of shipment from CNT. Warranty extensions are
available at time of initial order, or for products currently under
warranty with optional features #80xx. For products not currently under
warranty, optional features number #80xx may be used to re-establish
warranty coverage effective the last day of the prior warranty coverage
period.
(#8001) Warranty Extension (2 Yrs) for CNT FC/9000 64-Port Director (IBM 2042-001)
Summary: This feature extends the CNT hardware warranty period
for an additional two years with 24X7, same day service. Ordering this
feature with the 2042-001 will provide a total of three years. Ordering
the Maximum quantity (2), will provide a total of five years. Customers
with CNT products currently under warranty can order this feature as
Field Installable (MES). For products not currently under warranty, you
can order this feature as Field Installable (MES) to re-establish
warranty coverage effective the last day of the prior warranty coverage
period.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8001 and #8011 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#8011) Warranty Extension (3 Yrs) for CNT FC/9000 64-Port Director (IBM 2042-001)
Summary: This feature extends the CNT hardware warranty period
for an additional three years with 24X7, same day service. Ordering this
feature with the 2042-001 will provide a total of four years warranty.
Customers with CNT products currently under warranty can order this
feature as Field Installable (MES). For products not currently under
warranty, you can order this feature as Field Installable (MES) to
re-establish warranty coverage effective the last day of the prior
warranty coverage period.
- Minimum Number of Features per 2042-001: None.
- Maximum Number of Features per 2042-001: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8001 and #8011 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#8002) Warranty Extension (2 Yrs) for CNT FC/9000 128-Port Director (IBM 2042-128)
Summary: This feature extends the CNT hardware warranty period
for an additional two years with 24X7, same day service. Ordering this
feature with the 2042-128 will provide a total of three years. Ordering
the Maximum quantity (2), will provide a total of five years. Customers
with CNT products currently under warranty can order this feature as
Field Installable (MES). For products not currently under warranty, you
can order this feature as Field Installable (MES) to re-establish
warranty coverage effective the last day of the prior warranty coverage
period.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8002 and #8012 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#8012) Warranty Extension (3 Yrs) for CNT FC/9000 128-Port Director (IBM 2042-128)
Summary: This feature extends the CNT hardware warranty period
for an additional three years with 24X7, same day service. Ordering this
feature with the 2042-128 will provide a total of four years warranty.
Customers with CNT products currently under warranty can order this
feature as Field Installable (MES). For products not currently under
warranty, you can order this feature as Field Installable (MES) to
re-establish warranty coverage effective the last day of the prior
warranty coverage period.
- Minimum Number of Features per 2042-128: None.
- Maximum Number of Features per 2042-128: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8002 and #8012 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#8003) Warranty Extension (2 Yrs) for CNT FC/9000 256-Port Director (IBM 2042-256)
Summary: This feature extends the CNT hardware warranty period
for an additional two years with 24X7, same day service. Ordering this
feature with the 2042-256 will provide a total of three years. Ordering
the Maximum quantity (2), will provide a total of five years. Customers
with CNT products currently under warranty can order this feature as
Field Installable (MES). For products not currently under warranty, you
can order this feature as Field Installable (MES) to re-establish
warranty coverage effective the last day of the prior warranty coverage
period.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8003 and #8013 are mutually exclusive.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
(#8013) Warranty Extension (3 Yrs) for CNT FC/9000 256-Port Director (IBM 2042-256)
Summary: This feature extends the CNT hardware warranty period
for an additional three years with 24X7, same day service. Ordering this
feature with the 2042-256 will provide a total of four years warranty.
Customers with CNT products currently under warranty can order this
feature as Field Installable (MES). For products not currently under
warranty, you can order this feature as Field Installable (MES) to
re-establish warranty coverage effective the last day of the prior
warranty coverage period.
- Minimum Number of Features per 2042-256: None.
- Maximum Number of Features per 2042-256: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: #8003 and #8013 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Field Installable: Yes, both IPO and MES
- Cable Order: None.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited.
© IBM Corporation 2005.
Back to top
|
|
|
|