Plant
Description Machine Model(s) Feature Field
-------------------------------- ------- -------- ------- -----
NEMA 5-15P, 120v/15a
Power Cord, UK, 2.5m 2027 140, 232 1012 Plant
220v/10a
Power Cord, European, 2.5m 2027 140, 232 1013 Plant
220v/10a
Power Cord, Australian, 2.5m 2027 140, 232 1014 Plant
220v/10a
Power Cord, USA, 9 ft 10 in 2027 140, 232 1016 Plant
208-240v
Power Cord, Italy/Chile/Libya 2027 140, 232 1021 Plant
220v/10a
Power Cord, Israel, 2.5m 2027 140, 232 1022 Plant
250v/10a
Power Cord, Thai/Bolivia/Peru 2027 140, 232 1023 Plant
NEMA 6-15P, 250v/10a
Power Cord, Denmark 2027 140, 232 1024 Plant
250v/10a
Power Cord, Africa/Burma/Bang 2027 140, 232 1025 Plant
250v/10a
Power Cord, Switz/Liecht 2027 140, 232 1026 Plant
250v/10a
Power Cord, USA, 1.8m 240v/15a 2027 232 1027 Plant
Non-locking NEMA L6-15P
Power Cord, USA, 1.8m 240v/6a 2027 140, 232 1028 Plant
Twist-lock NEMA L6-15P
Power Cord, USA, 2.8m 240v/6a 2027 140, 232 1029 Plant
Twist-lock NEMA L6-15P
Power Cord, Japan, 2.8m 2027 140, 232 1030 Plant
NEMA 6-15P 240v/6
Power Cords - Model 140 and Model 232
One, and only one, country-specific power cord feature may be included
in the order for each Model 140 and Model 232. To ensure you receive the
correct country specific power cord, you must specify the power cord in
your initial plant order. The Model 140 and Model 232 are equipped with
one 110v U.S. Power Cord, and one rack PDU jumper in the base
configuration. In the U.S., all other U.S. power cord
selections are completely optional. For example, if a U.S.
220v Power Cord is desired, there are various optional U.S.
feature numbers to select from. For non-U.S. installations,
appropriate power cord selection is required. If the
Model 140 and Model 232 are not being installed in the
U.S., you must choose the appropriate power cord for the
country the machine will be installed in.
These features are plant install only; they may not be
ordered as MES.
(#1012 - #1030) Power Cords for the 2027-140 and 2027-232
US--->
- Minimum number of features for 2027-140 and 2027-232: None.
- Maximum number of features for 2027-140 and 2027-232: One.
<---US
AP, LA, CAN, EMEA--->
- Minimum number of features for 2027-140 and 2027-232: One.
- Maximum number of features for 2027-140 and 2027-232: One.
<---AP, LA, CAN, EMEA
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: All 2027-140 and 2027-232 power cord
features are mutually exclusive. For non-U.S. orders, you must
specify one Power Cord feature (#1012-#1030) in your initial
plant order for the 2027-140 and 2027-232.
- Customer Set-up: No.
- Limitations: None.
- Plant / Field Install: Plant install only.
Plant
Description Machine Model(s) Feature Field
-------------------------------- ------- -------- ------- -----
Installation in 2032-C40 Cabinet:
Inst SAN140M in Cab (Plant) 2027 140 9231 Plant
Inst SAN140M in Cab (Field) 2027 140 9232 Plant
Inst SAN32M1 in Cab (Plant) 2027 232 9233 Plant
Inst SAN32M1 in Cab (Field) 2027 232 9234 Plant
Field Install 2027-232 in IBM Cab. 2027 232 9237 Plant
Plant Install 2027-140 in 2027-C40 2027 140 9241 Plant
Field Install 2027-140 in 2027-C40 2027 140 9242 Plant
Plant Install 2027-232 in 2027-C40 2027 232 9243 Plant
Field Install 2027-232 in 2027-C40 2027 232 9244 Plant
Installation
You must specify in your Initial Plant Order if the TotalStorage SAN
m-type family will be plant or field installed in the 2032 Model C40,
2027 Model C40, or in a supported IBM cabinet. Note that the plant
installation features for Models 140 and 232 have matching/paired
features on the 2032 Model C40 and 2027 Model C40; both install
features must be specified.
Installation in a cabinet
(#9231) Inst SAN140M in Cab (Plant)
This feature specifies installation of the IBM TotalStorage
SAN140M director in a 2032 Model C40 Cabinet prior to being
shipped from the plant.
(#9232) Inst SAN140M in Cab (Field)
This feature specifies installation of the IBM TotalStorage
SAN140M director in a 2032 Model C40 Cabinet by IBM when the
switch is installed at the customer location.
- Minimum number of install features: One.
- Maximum number of install features: One.
- Prerequisites: None.
- Corequisites: For #9231, #9215 is required on the 2032 Model C40
- Compatibility Conflicts: #9231 and #9232 are mutually exclusive.
- Customer Setup: No.
- Limitations: None.
- Plant installable: Yes.
- Field Installable: No.
(#9233) Inst SAN32M1 in Cab (Plant)
(No Longer Available as of July 29, 2005)
This feature specifies installation of the IBM TotalStorage SAN32M-1
switch in a 2032 Model C40 cabinet prior to being shipped from the plant.
(#9234) Inst SAN32M1 in Cab (Field)
This feature specifies installation of the IBM TotalStorage SAN32M-1
switch in a 2032 Model C40 cabinet by IBM when the switch is installed at
the customer location. This feature includes shipment of a rack mount
kit suitable for 2032-C40 cabinet and industry-standard 19-inch racks.
(#9237) Field Install 2027-232 in IBM 7014 Cabinet
Installation of the IBM TotalStorage SAN32M-1 switch in a supported
IBM cabinet by IBM when the switch is installed at the customer location.
This feature includes shipment of a rack mount kit suitable for supported
IBM cabinet.
One of these features must be specified on the initial order of the
2027 Model 232.
- Minimum number of install features: One.
- Maximum number of install features: One.
- Prerequisites: None.
- Corequisites: #9233 requires #9216 on the 2032 Model C40
- Compatibility Conflicts: #9233, #9234, and #9237 are mutually
exclusive.
- Customer Setup: No.
- Limitations: None.
- Plant installable: Yes.
- Field Installable: No.
(#9241) Plant Install 2027-140 in 2027-C40
This feature provides factory installation of 2027-140 in a
2027-C40 Cabinet.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: Must select feature #9241 or #9242.
- Corequisites: Must specify feature #9225 on 2027-C40.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant / Field Installable: Plant install only.
(#9242) Field Install 2027-140 in 2027-C40
This feature provides field installation of 2027-140 in a 2027-C40
Cabinet.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: Must select feature #9241 or #9242.
- Corequisites: Must have sufficient space available in 2027-C40.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant / Field Installable: Initial Plant Order only.
(#9243) Plant Install 2027-232 in 2027-C40
This feature provides factory installation of 2027-140 in a
2027-C40 Cabinet.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: Must select feature #9243 or #9244.
- Corequisites: Must select feature #9226 on 2027-C40.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant / Field Installable: Plant install only.
(#9244) Field Install 2027-232 in 2027-C40
This feature provides field installation of 2027-140 in a 2027-C40
Cabinet.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: Must select feature #9243 or #9244.
- Corequisites: Must have sufficient space available in 2027-C40.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant / Field Installable: Initial Plant Order only.
Plant
Description Machine Model(s) Feature Field
-------------------------------- ------- -------- ------- -----
Fiber Optic Cables:
- Cable Coupler 50u SC/SC 2027 140, 232 1800 Both
- Cable Coupler 9u SC/SC 2027 140, 232 1801 Both
- Fiber Cable 9u 3m LC/SC 2027 140, 232 1805 Both
- Fiber Cable 50u 10m LC/SC 2027 140, 232 1810 Both
- Fiber Cable 50u 10m LC/LC 2027 140, 232 1811 Both
Transceivers (SFP):
- 2G SW SFP Transceiver 4-Pk 2027 232 3204 Both
- 2G LW SFP Transceiver 4-Pk 2027 232 3205 Both
- Extended LW 20Km Transceiver 2027 140, 232 3220 Both
- LW SFP Transceiver 2027 232 3230 Both
- SW SFP Transceiver 2027 232 3231 Both
- Extended LW 35Km Transceiver 2027 140, 232 3235 Both
- UPM 2Gb 4-pt w/4 SW Trans 2027 140 6210 Both
- UPM 2Gb 4-pt w/4 LW Trans 2027 140 6211 Both
SAN32M1 Open System Mgmt Server 2027 232 3002 Both
SAN32M1 SANtegrity Binding 2027 232 3007 Both
SAN32M1 FICON Mgt Server 2027 232 3008 Both
SAN32M1 Open Trunking 2027 232 3020 Both
SAN32M1 SANtegrity Authentication 2027 232 3018 Both
SAN32M1 Preferred Path 2027 232 3022 Both
SAN32M1 N_Port Virtualization 2027 232 3045 Both
SAN32M1 Full Volatility 2027 232 3050 Both
SAN32M1 Element Manager 2027 232 3779 Both
SAN140M Open Sys Mgmt Server 2027 140 6002 Both
SAN140M FICON In-band Mgt Svr 2027 140 6003 Both
SAN140M SANtegrity Binding 2027 140 6007 Both
SAN140M Open Trunking 2027 140 6120 Both
SAN140M 140-pt Element Mgr 2027 140 6140 Plant
SAN140M N_Port ID Virtualization 2027 140 6145 Both
SAN140M Full Volatility 2027 140 6150 Both
SAN140M SANtegrity Authentication 2027 140 6224 Both
SAN140M Preferred Path 2027 140 6422 Both
Fibre Optic cables:
(#1800) Cable coupler 50u SC/SC
One fiber cable coupler, multimode (50u), duplex SC/SC (female/female)
which will allow you to attach an existing fiber cable with SC type
connectors to a port with a LC type connector.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140, total of #1800 and #1801, maximum = 140
- Limitations: For 2027-232, total of #1800 and #1801, maximum = 32
- Plant Installable: Yes.
- Field Installable: Yes.
(#1801) Cable Coupler 9u SC/SC
One fiber cable coupler, singlemode (9u), duplex SC/SC (female/female)
which will allow you to attach an existing fiber cable with SC type
connectors to a port with a LC type connector.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140, total of #1800 and #1801, maximum = 140
- Limitations: For 2027-232, total of #1800 and #1801, maximum = 32
- Plant Installable: Yes.
- Field Installable: Yes.
(#1805) Fiber Cable 9u 3m LC/SC
One 3 m, singlemode (9u) fiber cable, LC/SC, that has a duplex (male)
SC connector at one end, and a duplex (male) LC connector at the other
end.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140, total of #1805, #1810, and #1811:
maximum = 140
- Limitations: For 2027-232, total of #1805, #1810, and #1811:
maximum = 32
- Plant Installable: Yes.
- Field Installable: Yes.
(#1810) Fiber Cable 50u 10m LC/SC
One 10 m, multimode (50u) fiber cable, LC/SC, that has a duplex (male)
LC connector at one end, and a duplex (male) SC connector at the other
end.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140, total of #1805, #1810, and #1811:
maximum = 140
- Limitations: For 2027-232, total of #1805, #1810, and #1811:
maximum = 32
- Plant Installable: Yes.
- Field Installable: Yes.
(#1811) Fiber Cable 50u 10m LC/LC
One 10 m, multimode (50u) fiber cable, LC/LC, that has duplex (male)
LC connectors at both ends.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140, total of #1805, #1810, and #1811:
maximum = 140
- Limitations: For 2027-232, total of #1805, #1810, and #1811:
maximum = 32
- Plant Installable: Yes.
- Field Installable: Yes.
Transceivers:
General Limitation for ordering UPMs on 2027-140:
Min = #6210 + #6211 + #6231 + #6232 = 4
Max = #6210 + #6211 + #6231 + #6232 = 35
General Limitation for ordering SFP transceivers on 2027-232:
Min = #3230 + #3231 + #3220 + #3235 (4 x #3204) + (4 x #3205) = 8
Max = #3230 + #3231 + #3220 + #3235 (4 x #3204) + (4 x #3205) = 32
(#3204) 2G SW SFP Transceiver 4-Pk
Four short-wave SFP fiber optic transceivers, each with LC connector.
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 8
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#3205) 2G LW SFP Transceiver 4-Pk
Four long-wave SFP fiber optic transceiver, each with LC connector and
supporting distances up to 10Km.
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 8
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#3220) Extended LW 20Km Transceiver
One extended-distance long-wave small form-factor pluggable (SFP)
transceiver that supports interconnection of SAN140M directors and
SAN32M1 switches at distances up to 20 kilometers across a single-mode
fiber optical cable connection. This extended LW transceiver when
installed in the SAN140M director, replaces one of the shortwave or
longwave transceivers on the 2 Gb UPM 4 port Modules, #6210 or #6211.
- Minimum Number of Features per 2027-140: None
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: 2027-140: total of #3220 and #3235: maximum = 140
- Limitations: 2027-232: Refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#3230) LW SFP Transceiver
One long-wave SFP fiber optic transceiver with LC connector,
supporting distances up to 10Km.
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#3231) SW SFP Transceiver
One short-wave SFP fiber optic transceiver with LC connector.
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: Refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#3235) Extended LW 35Km Transceiver
One extended distance long-wave small SFP transceiver that supports
interconnection of SAN140M directors and SAN32M1 switches at distances up
to 35 kilometers across a single-mode fiber optical cable connection.
This extended LW transceiver when installed in the SAN140M director,
replaces one of the shortwave or longwave transceivers on the 2 Gb UPM 4
port Modules, #6210 or #6211.
- Minimum Number of Features per 2027-140: None
- Maximum Number of Features per 2027-140: 140
- Minimum Number of Features per 2027-232: None
- Maximum Number of Features per 2027-232: 32
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: For 2027-140: total of #3220 and #3235: maximum = 140
- Limitations: For 2027-232: refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#6210) UPM 2Gb 4-pt w/4 SW Trans
One UPM, a 2 Gb/sec, 4-port module with four short-wave (LC SFP)
transceivers for the SAN140M director. The UPM is backwards compatible
with the 1 Gb/sec FPM, and speed is negotiated (at link bring up) on an
individual port-by-port basis.
- Minimum Number of Features per 2027-140: None
- Maximum Number of Features per 2027-140: 35
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
(#6211) UPM 2Gb 4-pt w/4 LW Trans
One UPM 2 Gb/sec, 4-port module with four long-wave (LC SFP)
transceivers for the SAN140M director. The UPM is backwards compatible
with the 1 Gb/sec FPM, and speed is negotiated (at link bring up) on an
individual port-by-port basis.
- Minimum Number of Features per 2027-140: None
- Maximum Number of Features per 2027-140: 35
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: refer to General Limitation above.
- Plant Installable: Yes
- Field Installable: Yes
Other features
(#3002) SAN32M1 Open Sys Mgmt Server
(No Longer Available as of June 24, 2005)
Open Systems Management software for the SAN32M1 switch.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3007) SAN32M1 SANtegrity Binding
Additional code within the SAN32M1 switch for SANtegrity security
capability enabling fabric and switch binding. This feature optionally
enhances the security of FCP environment, and is mandatory for FICON
cascading configurations.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3008) SAN32M1 FICON Mgt Server
Additional code within the SAN23M1 Enterprise Fibre Channel switch to
support in-band management of the Director by System Automation for
OS/390 and zSeries 900 Servers. System Automation OS/390 provides a
single point of control for managing connectivity in active I/O
configurations. It takes an active role in detecting unusual I/O
conditions and lets you view and change paths between a processor and an
Input/Output device using the dynamic switching capability of the
SAN23M1. This type of dynamic in-band management is currently in the
9032 ESCON Directors.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3018) SAN32M-1 SANtegrity Authentication
This feature provides the optional SANtegrity Authentication
activation.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: Requires SANtegrity Binding feature #3007.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Plant / Field Installable: Both.
(#3020) SAN32M1 Open Trunking
The Open Trunking feature is designed to increase the total throughput
between two SAN m-type directors and/or switches automatically by
redirecting traffic from high utilization links to links with available
bandwidth. Open Trunking helps continuously monitor loads on all links,
detect congestion, and can automatically balance traffic across available
Inter-Switch Links (ISLs) without operator interaction. The receiving
switch does not need to support Open Trunking capability.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3022) SAN32M1 Preferred Path
(No Longer Available as of July 26, 2005)
This feature is designed to allow a customer to define routes across a
fabric. The Preferred Path enhancement modifies the behavior of Open
Trunking by providing guidance for the balancing function. The Preferred
Path configuration helps address user preference regarding exit port
assignment but is subject to the standard rules regarding the FSPF
protocol.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3045) SAN32M1 N_Port ID Virtualization
This feature activates N_Port Virtualization on the IBM TotalStorage
SAN32M-1 switch. Requires E/OS 8.0 or higher.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: 1.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3050) SAN32M1 Full Volatility
This feature is designed to support high-security environments, which
that require no customer data be retained by the switch after power off.
The Full Volatility feature is designed to configure a switch or director
so that no frame data is stored after a power off.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#3779) SAN32M1 Element Manager
Software and license necessary for the SAN32M1 to be managed by the
Enterprise Fabric Connectivity (EFC) Manager.
- Minimum Number of Features per 2027-232: None.
- Maximum Number of Features per 2027-232: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#6002) SAN140M Open sys Mgmt Server
(No Longer Available as of June 24, 2005)
Open Systems Management software for the SAN140M director.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
(#6003) SAN140M FICON in-band Mgt Svr
Additional code within the SAN140M Enterprise Fibre Channel Director
to support in-band management of the Director by System Automation for
OS/390 and zSeries 900 Servers. System Automation OS/390 provides a
single point of control for managing connectivity in active I/O
configurations. It takes an active role in detecting unusual I/O
conditions and lets a customer view and change paths between a processor
and an Input/Output device using the dynamic switching capability of the
SAN140M. This type of dynamic in-band management is currently in the
9032 ESCON Directors.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
(#6007) SAN140M SANtegrity Binding
Additional code within the SAN140M director for SANtegrity security
capability enabling fabric and switch binding. This feature optionally
enhances the security of FCP environment, and is mandatory for FICON
cascading configurations.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
(#6120) SAN140M Open Trunking
The Open Trunking feature is designed to optimize the total throughput
between two SAN m-type directors and/or switches automatically by
redirecting traffic from high utilization links to links with available
bandwidth. Open Trunking helps continuously monitor loads on all links,
detect congestion, and automatically balance traffic across available
Inter-Switch Links (ISLs) without operator interaction. The receiving
switch does not need to support Open Trunking capability.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
(#6140) SAN140M Element Manager
Software and license necessary for the SAN140M to be managed by the
Enterprise Fabric Connectivity (EFC) Manager. This feature is required.
- Minimum Number of Features per 2027-140: One.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: No.
(#6145) SAN140M N_Port ID Virtualization
This feature activates N_Port Virtualization on the IBM TotalStorage
SAN140M switch. Requires E/OS 8.0 or higher.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: 1.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Plant Installable: Yes
- Field Installable: Yes
(#6150) SAN140M Full Volatility
This feature is designed to support high-security environments, which
require no customer data be retained after power off. The Full
Volatility feature is designed to configure a switch or director so that
no frame data is stored after a power off.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
(#6224) SAN140M SANtegrity Authentication
This feature provides the optional SANtegrity Authentication
activation.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: Requires SANtegrity Binding feature #6007.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Plant / Field Installable: Both.
(#6422) SAN140M Preferred Path
(No Longer Available as of July 26, 2005)
This feature is designed to allow a customer to define routes across a
fabric. The Preferred Path enhancement modifies the behavior of Open
Trunking by providing guidance for the balancing function. The Preferred
Path configuration helps address user preference regarding exit port
assignment but is subject to the standard rules regarding the FSPF
protocol.
- Minimum Number of Features per 2027-140: None.
- Maximum Number of Features per 2027-140: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: No.
- Limitations: None.
- Plant Installable: Yes.
- Field Installable: Yes.
Not available.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
© IBM Corporation 2005.