IBM U.S. Sales Manual
Revised:  July 26, 2005.

Table of contents  Document options  IBM U.S. Product Life Cycle Dates Publications Abstract Features -- Specify/Special/Exchange Highlights Accessories Description Machine Elements Models Supplies Technical Description    
doprint  
 
Switches
IBM U.S. Product Life Cycle Dates
Type ModelAnnounced AvailableMarketing Withdrawn Service DiscontinuedReplaced By
2026-E12 2004/10/052004/10/15 - - -
2026-224 2004/10/052004/10/15 - - -


 
Abstract

The IBM 2026 TotalStorage SAN portfolio expands with the introduction of the IBM TotalStorage SAN m-type family of mid-range and entry switch products. They can be architected and scaled into complex enterprise SANs using a high-availability backbone director with fabric switches at the edge to support cost-effective and high-performance solutions.

Model Abstract 2026-E12

The IBM 2026 SAN12M-1 entry switch Model E12 is designed to meet the needs of entry level SAN applications, first-time SAN deployments, departmental SANs, and application specific deployments. The SAN12M-1 entry switch offers 4, 8, or 12 non-blocking ports, providing 1 and 2 Gbps Fibre Channel ports utilizing industry standards-based auto-sensing and auto-rate-negotiating operation with Fabric and Public Loop attached devices. The optional Full Fabric Activation feature enables support for Inter-Switch Link (ISL) and full bandwidth extended distance operation up to 10 Km at 2 Gbps (when configured with longwave transceivers), to help disaster tolerance solutions.

Model Abstract 2026-224

The IBM 2026 SAN24M-1 mid-range switch Model 224 is designed to provide storage consolidation, high availability, and high-port density in a 1-U rack mount chassis. The SAN24M-1 supports both long-wave and short-wave transceivers, offers up to twenty-four non-blocking ports, in eight-port increments, with support for auto-sensing, auto-rate-negotiation 1 and 2 Gb/sec Fibre Channel, Arbitrated Loop (FC-AL), and Fabric (FC-SW). The SAN24M-1 is designed to provide integrated support for full Fabric and FC-AL tape attachment to SAN m-type family of enterprise directors and switches.
Back to topBack to top
 

Highlights

The initial offering of the IBM TotalStorage SAN m-type family of mid-range and entry switch products includes the IBM TotalStorage SAN24M-1 mid-range switch and IBM TotalStorage SAN12M-1 entry switch.

The SAN24M-1 is a mid-range switch designed to offer:

  • Integrated support for Full-Fabric and FC-AL tape attachment to IBM SAN m-type family of enterprise director and switch products

  • Up to 24 non-blocking Fibre Channel ports, in 8-port increments, with auto-sensing, and auto-rate-negotiation support for both 1 and 2 Gb/sec devices

  • In-band management with optional Open Systems Management Server capability and optional SANtegrity to lock-down key attributes of SAN infrastructure

  • Longwave transceivers that can field installed in the first four ports, supporting distances up to 10 Km

The SAN12M-1 is an entry-level switch designed to offer:

  • Entry-level fabric switch capabilities to help address the needs of small to medium-sized business SAN applications, first-time SAN deployments, departmental SANs, and application specific deployments

  • 4, 8, or 12 non-blocking ports, providing 1 and 2 Gbps Fibre Channel support for Fabric and Public Loop-attached devices

  • Optional Full-Fabric Activation supports ISL and full-bandwidth, extended distance operation up to 10 Km at 2 Gbps to help disaster tolerance solutions

  • Ease-of-use with zoning support, SANpilot Web-based management tool, HotCAT nondisruptive microcode update

Back to topBack to top
 
Description

The initial offering of the IBM TotalStorage SAN m-type family of mid-range and entry switch products includes:

  • IBM TotalStorage SAN24M-1 mid-range switch (2026-224)
  • IBM TotalStorage SAN12M-1 entry switch (2026-E12)

The IBM TotalStorage SAN24M-1 mid-range switch is designed to provide storage consolidation, high availability, and high-port density in a 1-U rack mount chassis. It supports longwave and shortwave transceivers, offers up to twenty-four non-blocking ports, in eight-port increments, with support for auto-sensing, auto-rate-negotiation 1 and 2 Gb/sec Fibre Channel, Arbitrated Loop (FC-AL), and Fabric (FC-SW). It helps you to purchase upgrades to connectivity when needed and integrates support for full-Fabric and FC-AL tape attachment to SAN m-type family of enterprise directors and switches.

The IBM TotalStorage SAN12M-1 entry switch is designed to address the needs of entry-level SAN applications, first-time SAN deployments, departmental SANs, and application-specific deployments. It offers 4, 8, or 12 non-blocking ports, providing 1 and 2 Gbps Fibre Channel ports that use industry standards-based auto-sensing and auto-rate-negotiating operation with Fabric and Public Loop attached devices. The optional Full-Fabric Activation feature enables support for Inter-Switch Link (ISL) and full bandwidth extended distance operation up to 10 Km at 2 Gbps (when configured with longwave transceivers), to help support disaster tolerance solutions.

Support for some configurations may not be available on the initial availability date.

IBM TotalStorage SAN12M-1 entry switch (2026-E12)

The SAN12M-1 is an entry-level switch specifically designed to address the needs of:

  • Entry-level SAN applications
  • First-time SAN deployments
  • Departmental SANs
  • Application specific deployments

It offers 4, 8, or 12 non-blocking ports, providing 1 and 2 Gbps Fibre Channel ports utilizing industry standards-based auto-sensing and auto-rate-negotiating operation with Fabric and Public Loop attached devices. The optional Full-Fabric Activation feature enables support for ISL and full bandwidth, extended distance operation up to 10 Km at 2 Gbps (when configured with longwave transceivers), to help disaster tolerance solutions.

IBM TotalStorage SAN24M-1 mid-range switch (2026-224)

The SAN24M-1 is a mid-range switch designed to support:

  • storage consolidation
  • high availability
  • high-port density in a 1-U rack mount chassis

It supports long-and short-wave transceivers, offers up to twenty-four non-blocking ports, in eight-port increments, with support for auto-sensing, auto-rate-negotiation 1 and 2 Gb/sec Fibre Channel, Arbitrated Loop (FC-AL), and Fabric (FC-SW).

The SAN24M-1 mid-range switch helps you to add connectivity when needed and provides integrated support for Full-Fabric and FC-AL tape attachment to SAN m-type family of enterprise directors and switches.

Supported servers and storage systems

Each new switch supports Fibre Channel connectivity for:

  • Servers:
    • IBM eServer zSeries and selected S/390 servers (SAN24M-1 only)
    • IBM eServer pSeries and selected RS/6000 servers
    • IBM eServer iSeries and selected AS/400 servers
    • IBM eServer xSeries and selected Netfinity servers
    • Other Intel-based servers running Linux, Microsoft Windows 2000, or Windows 2003
    • Selected Sun and HP servers

  • Storage Software:
    • IBM TotalStorage SAN Volume Controller (SVC)
    • IBM TotalStorage SAN File System (SFS)

  • Storage Systems:
    • IBM TotalStorage Enterprise Storage Server
    • IBM TotalStorage FAStT Family of Storage Servers
    • IBM TotalStorage Enterprise Tape System 3590 and 3592
    • IBM TotalStorage Enterprise Tape Library 3494
    • IBM TotalStorage Enterprise Tape Controller 3592 Model J70
    • IBM TotalStorage Enterprise Tape Controller 3590 Model A60
    • IBM 3581, 3582, 3583, and 3584 Ultrium LTO Tape Libraries
    • Other selected storage systems

Note: For attachment to tape devices using Fibre Channel Arbitrated Loop (FC-AL), the SAN140M and SAN32M-1 require the use of the SAN24M-1.

Accessibility by people with disabilities

For hardware offerings

The following features support use by people with disabilities:

  • Tactile landmarks on home keys.

  • Visual or tactile and auditory indicator of each toggle key state or make the state of that toggle key available to software so that it can provide alternative indicators.

  • Industry standard keyboard and keypad layout.

  • Keys which are tactilely discernible without activating them.

  • Key repeat delay is adjustable to at least two seconds.

  • Industry standard ports for alternative input and output devices.

  • Industry standard display connectors.

  • Non-glare screen that allows displays to be repositioned.

  • Color as an enhancement, not as the only way to distinguish keys, controls, or labels.

  • Easily readable lettering and high contrast colors.

  • An interface so that use of system sounds can be known to software.

  • Physical volume control or an interface so that volume can be controlled with software.

  • Upon request, provide documentation in an accessible format.

Software interface:

  • Keyboard equivalents are provided for all actions.

  • The product does not interfere with keyboard accessibility features built into the operating system.

  • Labels are associated with controls, objects, icons, and images.

  • Text is provided through standard system function calls or API.

  • Color as an enhancement, not as the only way to convey information or indicate an action.

  • System settings for font, size, and color for all user interface controls.

  • Avoids the use of blinking text, objects or other elements.

  • Documentation in an accessible format

  • Documentation on all accessibility features including keyboard access

Back to topBack to top
 
Models

Model Summary Matrix

Models FC Ports Transceivers
E12 12 4, 8, or 12 SFPs (SW and LW total)
224 24 8, 16, or 24 SW SFP (may substitute up to 4 LW)

Customer Setup (CSU)

Yes.

Devices Supported

Specific details on supported devices; storage products attachability, SAN connectivity products, and configuration options are available on the Web at:

http://www.ibm.com/totalstorage/SAN/m-type

Model Conversions

None.
Back to topBack to top
 
Technical Description
TOC Link Physical Specifications TOC Link Operating Environment TOC Link Limitations
TOC Link Hardware Requirements TOC Link Software Requirements

Physical Specifications

2026 Model E12:

  • Width: 43.7 cm (17 in)
  • Depth: 47.3 cm (17.5 in)
  • Height: 4.1 cm (1.75 in)
  • Weight: 6.5 kg (15 lb)

2026 Model 224:

  • Width: 43.7 cm (17 in)
  • Depth: 47.3 cm (17.5 in)
  • Height: 4.1 cm (1.75 in)
  • Weight: 8.6 kg (20 lb)

To assure installability and serviceability in non-IBM industry standard racks, review the installation planning information for any product specific installation requirements.

Operating Environment

  • Temperature: -40 to 40.0 degrees C (-40 to +104 degrees F)
  • Relative Humidity: 5% to 80% (percent)
  • Wet Bulb (Caloric Value): 127 BTU/Hr
  • Electrical Power: 1.25 - 2A
  • Noise Level: 5.5 to 6.9 Bels

EMC Conformance:

  • ICES 003 Class A
  • FCC Part 15 Class A
  • VCCI Class A ITE
  • EN55022 Class A
  • EN55024
  • AS NZS 3548 Class A
  • CISPR22 Class A

Product Safety/Country Testing/Certification:

  • CSA 60950 (Canada)
  • UL Standard 60950
  • IEC EN60950 (CF-Europe)
  • EN60950 (Germany)
  • TUV, NEMKO

Limitations

2026-E12 cannot be managed using EFCM (Enterprise Fabric Control Manager). SANpilot (embedded GUI) product manager via Ethernet access using standard web browser may be used.

Hardware Requirements

Rack Requirements

An industry-standard 19-inch rack, or equivalent, with adequate space available (1 EIA unit for the Model E12 and Model 224), and sufficient power and cooling is required to support the SAN m-type family of mid-range and entry switch products.

Non-rack-mounted installation is supported.

The Model E12 and Model 224 are equipped with one 110v U.S. Power Cord and one rack PDU jumper in the base configuration. In the U.S., all other U.S. power cord selections are completely optional. For example, if a U.S. 220v Power Cord is desired, there are various, optional U.S. feature numbers to select from. For non-U.S. installations, appropriate power cord selection is required. If the Model E12 or Model 224 are not being installed in the U.S., you must choose the appropriate power cord for the country the machine will be installed in.

Software Requirements

Specific details on supported operating system releases are available on the Web at:

http://www.ibm.com/totalstorage/SAN/m-type

Back to topBack to top
 
Publications

The following publications are shipped with the product on a CD-ROM.

Additional copies of individual publications are available on the Internet at:

http://www.ibm.com/totalstorage/SAN/m-type
                                          Order
Title                                     Number
--------------------------------------    ---------
IBM TotalStorage SAN12M1 Fabric Switch    GC26-7666
 Customer Setup and Operations Manual
IBM TotalStorage SAN24M1 Fabric Switch    GC26-7667
 Customer Setup and Operations Manual
Enterprise Operating System Command       GC26-7669
 Line Interface User Manual for IBM
 TotalStorage Products
SANpilot User Manual for IBM              GC26-7670
 TotalStorage Products
McDATA Element Manager for IBM            GC26-7672
 TotalStorage SAN24M1 and 12M1
 Switch User Manual
McDATA Fabricenter Equipment Cabinet      GC26-7674
 Installation and Service for IBM
 Products Manual
IBM Products in a SAN Environment         GC26-7675
 Planning Manual
IBM TotalStorage SAN 2026 Model E12       GC26-7690
 (SAN12M1) Statement of Limited
 Warranty
IBM TotalStorage SAN 2026 Model E24       GC26-7691
 (SAN24M1) Statement of Limited
 Warranty

Back to topBack to top
 
Features -- Specify/Special/Exchange
TOC Link No Charge Specify Codes TOC Link Special Feature Codes -- Chargeable TOC Link Feature Exchanges

No Charge Specify Codes

                                 Machine                     Plant
Description                      type     Model     Feature  Field
-----------------------------    -------  --------  -------  -----
Power Cords
 Power Cord, UK, 2.5m              2026   E12, 224    1012   Plant
  220v/10a
 Power Cord, European, 2.5m        2026   E12, 224    1013   Plant
  220v/10a
 Power Cord, Australian, 2.5m      2026   E12, 224    1014   Plant
  220v/10a
 Power Cord, USA, 9 ft 10 in       2026   E12, 224    1016   Plant
  208-240v
 Power Cord, Italy/Chile/Libya     2026   E12, 224    1021   Plant
  220v/10a
 Power Cord, Israel, 2.5m          2026   E12, 224    1022   Plant
  250v/10a
 Power Cord, Thai/Bolivia/Peru     2026   E12, 224    1023   Plant
  NEMA 6-15P, 250v/10a
 Power Cord, Denmark               2026   E12, 224    1024   Plant
  250v/10a
 Power Cord, Africa/Burma/Bang     2026   E12, 224    1025   Plant
  250v/10a
 Power Cord, Switz/Liecht          2026   E12, 224    1026   Plant
  250v/10a
 Power Cord, USA, 1.8m 240v/15a    2026   E12, 224    1027   Plant
  Non-locking NEMA L6-15P
 Power Cord, USA, 1.8m 240v/6a     2026   E12, 224    1028   Plant
  Twist-lock NEMA L6-15P
 Power Cord, USA, 2.8m 240v/6a     2026   E12, 224    1029   Plant
  Twist-lock NEMA L6-15P
 Power Cord, Japan, 2.8m           2026   E12, 224    1030   Plant
  NEMA 6-15P 240v/6
 Plant Install 2026-224 in 2027-C40       224         9245   Plant
 Field Install 2026-224 in 2027-C40       224         9246   Plant

To ensure you receive the correct country-specific power cord for the SAN24M-1 or SAN12M-1, specify the appropriate feature (#10xx).

  • Minimum number of features per SAN m-type family: One.
  • Maximum number of features per SAN m-type family: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field installable: No.
  • Cable order: None.

Power Cords for non-rack Installation

The SAN24M-1 mid-range switch includes a pair of PDU jumper cords in the base, suitable for rack mount installation in the 2032-C40 cabinet. The SAN12M-1 entry switch includes one PDU jumper cord in the base, suitable for rack mount installation in the 2032-C40 cabinet. To order the correct country-specific power cord for the SAN24M-1 or SAN12M-1, specify the appropriate feature (#10xx).

Power cords - Model E12 and Model 224: One, and only one, country-specific power cord feature may be included in the order for each Model E12 and Model 224. To ensure you receive the correct country specific power cord, you must specify the power cord in your initial plant order. The Model E12 and Model 224 are equipped with one 110v US Power Cord, and one rack PDU jumper in the base configuration. In the U.S., all other U.S. power cord selections are completely optional. For example, if a U.S. 220v Power Cord is desired, there are various optional U.S. feature numbers to select from. For non-U.S. installations, appropriate power cord selection is required. If the Model E12 and Model 224 are not being installed in the U.S., you must choose the appropriate power cord for the country the machine will be installed in.

These features are plant install only; they may not be ordered as MES.

(#1012 - #1030) Power Cords for the 2026-E12 and 2026-224

    US--->

  • Minimum number of features for 2026-E12 and 2026-224: None.
  • Maximum number of features for 2026-E12 and 2026-224: One.

    <---US

    AP, LA, CAN, EMEA--->

  • Minimum number of features for 2026-E12 and 2026-224: One.
  • Maximum number of features for 2026-E12 and 2026-224: One.

    <---AP, LA, CAN, EMEA

  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: All 2026-E12 and 2026-224 power cord features are mutually exclusive. For non-U.S. orders, you must specify one Power Cord feature (#1012 - #1030) in your initial plant order for the 2026-E12 and 2026-224.
  • Customer Setup: No.
  • Limitations: None.
  • Plant / Field Install: Plant install only.

Install features

(#9235) Inst SAN24M1 IN Cab (Plant)

This feature specifies installation of the IBM TotalStorage SAN24M-1 mid-range switch in a 2032 Model C40 cabinet prior to being shipped from the plant.

(#9236) Inst SAN24M1 IN Cab (Field)

This feature specifies customer installation of the IBM TotalStorage SAN24M-1 mid-range switch in a 2032 Model C40 cabinet at the customer location.

For installation in a cabinet, one of these features may be specified on the initial order of the SAN24M-1. Note that for plant installation, the feature is paired with a companion feature of the 2032 Model C40 which must be specified on the 2032 Model C40 order.

  • Minimum number of install features: None.
  • Maximum number of install features: One.
  • Prerequisites: None.
  • Corequisites: #9235 requires #9217 on the 2032-C40.
  • Compatibility Conflicts: #9235 and #9236 are mutually exclusive.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: No.

(#9245) Plant Install 2026-224 in 2027-C40

This feature provides factory installation of 2027-224 in a 2027-C40 Cabinet.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: Must select feature #9245 or #9246. must select feature #9227 on 2027-C40.
  • Corequisites: Must select feature #9227 on 2027-C40.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Plant / Field Installable: Plant install only.

(#9246) Field Install 2026-224 in 2027-C40

This feature provides field installation of 2027-224 in a 2027-C40 Cabinet.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: Must select feature #9245 or #9246.
  • Corequisites: Must have sufficient space available in 2027-C40.
  • Compatibility Conflicts: None.
  • Customer Setup: No.
  • Limitations: None.
  • Plant / Field Installable: Initial Plant Order only.

Special Feature Codes -- Chargeable

                                 Machine                     Plant
Description                      type     Model     Feature  Field
-----------------------------    -------  --------  -------  -----
Cable Coupler 50u SC/SC            2026   E12, 224    1800   Both
Cable Coupler 9u SC/SC             2026   E12, 224    1801   Both
Fiber Cable 9u 3m LC/SC            2026   E12, 224    1805   Both
Fiber Cable 50u 10m LC/SC          2026   E12, 224    1810   Both
Fiber Cable 50u 10m LC/LC          2026   E12, 224    1811   Both
SAN12M1 Full Fabric Capable        2026   E12         4301   Both
SAN12M1 4pt FlexPort Exp Kt        2026   E12         4304   Both
SAN24M1 Open Sys Mgmt Svr          2027   224         4501   Both
SAN24M1 SANtegrity Binding         2027   224         4503   Both
SAN24M1 8pt FlexPort               2026   224         4508   Both
SAN24M1 Element Manager            2027   224         4510   Both
SAN24M1 SANtegrity Authentication  2026   224         4515   Both
SAN24M1 Open Trunking              2026   224         4520   Both
SAN24M1 Preferred Path             2027   224         4522   Both
SAN24M1 Full Volatility            2027   224         4550   Both
LW SFP Transceiver                 2026   E12, 224    4630   Both

Transceivers - Small Form-Factor Pluggable (SFP)

The IBM TotalStorage SAN12M-1 entry switch supports a maximum of 12 (four are provided with the IBM TotalStorage SAN12M-1 entry switch) shortwave optical SFP ports. The maximum number of longwave optical SFP ports on the SAN12M-1 is 12.

The IBM TotalStorage SAN24M-1 mid-range switch supports a maximum of 24 (eight are provided with the IBM TotalStorage SAN24M-1 mid-range switch) shortwave optical SFP ports. The maximum number of longwave optical SFP ports on the SAN24M-1 is 4.

(#1800) Cable Coupler 50u SC/SC

One fiber cable coupler, multimode (50u), duplex SC/SC (female/female) which will allow you to attach an existing fiber cable with SC type connectors to a port with a LC type connector.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 24.
  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
    • For 2026-224: Total of #1800 and #1801 may not exceed 24.
    • For 2026-E12: Total of #1800 and #1801 may not exceed 12.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#1801) Cable Coupler 9u SC/SC

One fiber cable coupler, singlemode (9u), duplex SC/SC (female/female) which will allow you to attach an existing fiber cable with SC type connectors to a port with a LC type connector.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 24.
  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
    • For 2026-224: Total of #1800 and #1801 may not exceed 24.
    • For 2026-E12: Total of #1800 and #1801 may not exceed 12.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#1805) Fiber Cable 9u 3m LC/SC

One 3-meter, singlemode (9u) fiber cable, LC/SC, that has a duplex (male) SC connector at one end, and a duplex (male) LC connector at the other end.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 24.
  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
    • For 2026-224: Total of #1805, #1810, and #1811 may not exceed 24.
    • For 2026-E12: Total of #1805, #1810, and #1811 may not exceed 12.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#1810) Fiber Cable 50u 10m LC/SC

One 10-meter, multimode (50u) fiber cable, LC/SC, that has a duplex (male) LC connector at one end, and a duplex (male) SC connector at the other end.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 24.
  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
    • For 2026-224: Total of #1805, #1810, and #1811 may not exceed 24.
    • For 2026-E12: Total of #1805, #1810, and #1811 may not exceed 12.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#1811) Fiber Cable 50u 10m LC/LC

One 10-meter, multimode (50u) fiber cable, LC/LC, that has duplex (male) LC connectors at both ends.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 24.
  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
    • For 2026-224: Total of #1805, #1810, and #1811 may not exceed 24.
    • For 2026-E12: Total of #1805, #1810, and #1811 may not exceed 12.
  • Plant installable: Yes.
  • Field Installable: Yes.

In many situations, the required lengths and installation of fiber optic cables will be unique to each customer's configuration and facility specifications. IBM Network Integration and Deployment Services, offered by IBM Global Services, can provide assistance for these unique cabling and installation requirements. For situations where the Fibre Channel components and attaching subsystems are within the distances available, there are several features available to accommodate these simple installations.

(#4301) SAN12M1 Full Fabric Capable

Supports Inter-Switch Link (ISL) and full bandwidth extended distance operation up to 10 Km at 2 Gbps (when configured with the optional LW SFP Transceiver #4630), to help disaster tolerance solutions.

  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4304) SAN12M1 4pt FlexPort Exp Kit

Enables an additional 4 ports on the SAN12M1 entry switch (2026-E12) and includes four customer-installable SW SFP Transceivers and FlexPort activation key.

  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: Two.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4501) SAN24M1 Open Sys Mgmt Server

(No Longer Available as of June 24, 2005)

Open Systems Management activation for the SAN24M1 switch.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4503) SAN24M1 SANtegrity Binding

Additional code within the SAN24M1 switch for SANtegrity security capability enabling fabric and switch binding. This feature optionally enhances the security of FCP environment, and is mandatory for FICON cascading configurations.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4508) SAN24M1 8pt FlexPort

Enables an additional 8 ports on the SAN24M1 mid-range switch (2026-224) and includes eight customer-installable SW SFP Transceivers and FlexPort activation key.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: Two.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations:
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4510) SAN24M1 Element Manager

Software and license necessary for the SAN24M1 to be managed by the Enterprise Fabric Connectivity (EFC) Manager.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4515) SAN24M-1 SANtegrity Authentication

This feature provides the optional SANtegrity Authentication activation.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2027-224: One.
  • Prerequisites: Feature SANtegrity Binding #4503.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant / Field Installable: Both.

(#4520) SAN24M1 Open Trunking

Open Trunking is designed to optimize the total throughput between two SAN m-type directors and/or switches automatically by redirecting traffic from high utilization links to links with available bandwidth. Open Trunking helps continuously monitor loads on all links, detect congestion, and automatically balance traffic across available Inter-Switch Links (ISLs) without operator interaction. The receiving switch does not need to support Open Trunking capability.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4522) SAN24M1 Preferred Path

(No Longer Available as of July 26, 2005)

Designed to allow a customer to define routes across a fabric. The Preferred Path enhancement modifies the behavior of Open Trunking by providing guidance for the balancing function. The Preferred Path configuration helps address user preference regarding exit port assignment but is subject to the standard rules regarding the FSPF protocol.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4550) SAN24M1 Full Volatility

Designed to support high-security environments, which require no customer data be retained after power off. The Full Volatility feature is designed to configure a switch or director so that no frame data is stored after a power off.

  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: One.
  • Prerequisites: None.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

(#4630) LW SFP Transceiver

One long-wave SFP fiber optic transceiver with LC connector, supporting distances up to 10Km.

  • Minimum Number of Features per 2026-E12: None.
  • Maximum Number of Features per 2026-E12: 12.
  • Minimum Number of Features per 2026-224: None.
  • Maximum Number of Features per 2026-224: 4.
  • Prerequisites: None for 2026-224. Feature #4301 for 2026-E12.
  • Corequisites: None.
  • Compatibility Conflicts: None.
  • Customer Setup: Yes.
  • Limitations: None.
  • Plant installable: Yes.
  • Field Installable: Yes.

Feature Exchanges

Not available.
Back to topBack to top
 
Accessories

None.

Customer Replacement Parts

None.
Back to topBack to top
 
Machine Elements

None.
Back to topBack to top
 
Supplies

None.

Diskettes

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Windows is a trademark of Microsoft Corporation.
 © IBM Corporation 2005.
Back to topBack to top