The IBM TotalStorage SAN16B-2 Express Model supports 4 Gbps Fiber
Channel capabilities for systems that support 4 Gbps throughput. This
improved performance is designed to support storage networking demands to
help improve throughput and enhance security.
This model is designed to provide:
- 4 Gbps port-to-port throughput with auto-sensing capability for
connecting to existing 1, 2, and future 4 Gbps host servers, storage, and
switches
- Up to 16 non-blocking ports with full duplex throughput at 1, 2, or 4
Gbps link speeds
- Includes eight 4 Gbps shortwave SFP transceivers
- High-availability features designed to offer automatic path routing,
and many nondisruptive firmware upgrades
- Scalable ports on demand in 8-, 12-, or 16-port increments to
accommodate a broad range of connectivity solutions in a 1 U form factor
for enhanced port density and space utilization
- Scalability from small to midrange SAN fabric environments
- Open FCP support
- Full compatibility with existing IBM TotalStorage SAN b-type switches
(IBM 2005, 2109, and 3534)
- Base 16B model firmware features - Advanced Zoning and WebTools
- Optional features - Additional Port Activation, Fabric Watch,
Extended Fabrics, Remote Switch, Advanced Security, Enhanced ISL
Trunking, and Performance Monitoring
- Support for 4 Gbps shortwave and 2 Gbps longwave Small Form Factor
Pluggable (SFP) optic transceivers
The IBM TotalStorage SAN16-B Express Model offers:
- Up to 16 FC ports that are designed to:
- Provide multiple simultaneous connections, each capable of throughput
speeds of 1, 2, or 4 Gbps with a maximum latency of 2 microseconds
- Auto sense and self-negotiate to the highest speed (1, 2, or 4
gigabits) supported by the server, storage, or switch
- Self-configure as F_ports, FL_ports, or E_ports (E_ports require Full
Fabric Activation)
- Operation with SFP optical transceivers:
- Supports up to 4 Gbps speeds with 4 Gbps shortwave SFPs for distances
up to 150 meters
- Supports 1 and 2 Gbps speeds with 2 Gbps longwave SFPs for distances
up to 10 kilometers
- Includes eight 4 Gbps shortwave SFP transceivers in base
- 1 U form factor is designed to enable enhanced port density and rack
space utilization. The SAN16B-2 fabric switch can also be ordered with
country-specific power cords for tabletop use.
- Web browser interface compatible with any Java-enabled browser is
designed to provide configuration monitoring and diagnostics using the
Internet or intranet.
- Scalable ports on demand (8, 12, or 16 ports) to accommodate a broad
range of connectivity solutions for a wide variety of host and storage
types (optional Port Activation feature available for upgrade to 12 and
16 ports).
- Compatibility with IBM TotalStorage SAN b-type switch family (IBM
2005, 2109, and 3534).
- Auto Fabric discovery is designed to allow external host and storage
systems to discover other supported SAN-enabled systems that are
connected to the fabric.
- Fabric Services such as Advanced Zoning and WebTools.
Optional features
SAN16B-2 Express Model 4-port upgrade option (P/N 22R5332)
- Additional Port Activation enables upgrade in 4-port increments from
8-to 12-and 12-to 16-ports.
- The base SAN16B-2 Express model activates the first eight ports (0 to
7). You may optionally purchase port activation for ports eight to
eleven (first four-port increment), and ports twelve to fifteen (second
four-port increment)
- Includes four 4 Gbps shortwave SFP transceivers
16B Advanced Security Activation (part number 22R4891)
Advanced Security Activation is designed to enable policy-based
security mechanisms integrated within Fabric Operating System V2.6, V3.1,
and V4.1.
16B 4-Port Activation (part number 22R4901)
This feature enables additional port activation for ports 8 to 11
(first four port increment) or ports 12 to 15 (second four port
increment) in the 16B switch. Port activation features do not include
fiber optic transceivers.
16B Fabric Watch (part number 22R4904) Fabric Watch enables
real-time proactive awareness of the health, performance, and security of
each switch, and is designed to automatically alert network managers to
problems in order to help avoid costly failures.
16B Full Fabric Activation (P/N 22R5460)
Full Fabric Activation is required to enable E_Ports. The switch by
default cannot be connected to another switch until Full Fabric is
installed. Without the license the switch can still be directly
connected to hosts and storage devices.
16B Performance Bundle Activation (part number 22R5469)
Performance Bundle Activation supports Enhanced ISL Trunking and
Performance Monitoring capabilities.
Supported servers and storage systems
The IBM TotalStorage SAN16B-2 fabric switch is designed to support FC
connectivity for the following:
Servers
- IBM eServer pSeries and selected RS/6000 servers
- IBM eServer iSeries and selected AS/400 servers
- IBM eServer xSeries and selected Netfinity servers
- Other Intel-based servers with Linux and Microsoft Windows 2000 and
Windows 2003
- Selected Sun and HP servers
- IBM TotalStorage SAN Volume Controller (SVC)
- IBM TotalStorage SAN File System (SFS)
Storage systems
- IBM TotalStorage DS8000
- IBM TotalStorage DS6000
- IBM TotalStorage DS4000
- IBM TotalStorage Enterprise Storage Server
- IBM TotalStorage FAStT Family of Storage Servers
- IBM TotalStorage 3580, 3588, 3590, and 3592 Tape Drives
- IBM TotalStorage 3494, 3582, 3583, and 3584 Tape Libraries
- IBM TotalStorage 3581 Tape Autoloader
- IBM TotalStorage 3584 High Availability Frame Model HA1
- Other selected storage systems
For specific support dates, configuration options, server models,
operating systems levels, attachment capabilities, and throughput
connectivitvy speeds, visit:
- http://www.ibm.com/totalstorage/san/b-type
Accessibility by people with disabilities
For hardware offerings
The following features support use by people with disabilities:
- Ports and connectors support connection of industry-standard devices.
Section 508 of the U.S. Rehabilitation Act
The IBM TotalStorage SAN16B-2 Express Model is capable, as of August
26, 2005, when used in accordance with associated IBM documentation, of
satisfying the applicable requirements of Section 508 of the
Rehabilitation Act, provided that any assistive technology used with the
product properly interoperates with it.
A U.S. Section 508 Voluntary Product Accessibility Template (VPAT) can
be requested via:
- http://www-3.ibm.com/able/product_accessibility/index.html
Back to top
Models
|
Model Summary Matrix
Model |
FC Ports |
Transceivers |
16B |
16 |
None in Base |
Customer Setup (CSU)
Yes.
Devices Supported
Specific details on supported devices; storage products attachability,
SAN connectivity products, and configuration options are available on the
Web at:
- http://www.ibm.com/totalstorage/san/b-type
Model Conversions
None.
Back to top
Technical Description
|
The IBM TotalStorage SAN16B-2 (200516B) Express Model provides a 1 U
rack mount fabric switch, designed to provide Ports on Demand
scaleability with 8, 12, or 16 ports, with each port capable of
throughput speeds of 1, 2, or 4 Gbps, and maximum latency of 2
microseconds. Additionally, each port is designed to offer auto sensing
and self-negotiation to the highest speed (1, 2, or 4 Gbps) supported by
the attached server, storage, or switch, as well as self-configuration as
F_ports, FL_ports, or E_ports.
The base function of the SAN16B-2 fabric switch includes Fibre Channel
fabric services, Advanced Zoning, WEB TOOLS, and Fabric Watch, as well as
high availability design with redundant hot pluggable power supplies and
fans, automatic path routing, and many nondisruptive firmware upgrades
The SAN16B-2 fabric switch comes with the first eight ports enabled in
the base with 4-Gbps shortwave SFPs in the base product. Customers may
purchase an additional 4-port upgrade option (22R5332) for a total of 12,
or 16 ports enabled.
The SAN16B-2 fabric switch supports operation with Small form-factor
pluggable (SFP) optical transceivers. Operation with 4-Gbps capable
shortwave SFPs provides distances up to 150 meters. Operation with 2
Gbps capable long wave SFPs provides distances up to 10 kilometers.
The SAN16B-2 fabric switch supports compatibility with IBM
TotalStorage SAN b-type switch family (IBM 2005, 2109 and 3534).
The IBM TotalStorage SAN16B-2 Express Model can be configured for
either rack-mount or tabletop use. For tabletop use you must order the
required country-specific power cords.
Enclosure: 2005-16B (1U), 19-in.-EIA compliant, with non-port to port
airflow.
- Height: 4.29 cm (1.69 in)
- Width: 42.85 cm (16.87 in)
- Depth: 30.73 cm (12.10 in)
- System Weight: 3.99 kg (8.8 lb) without media
To support installability and serviceability in non-IBM industry
standard racks, review the installation planning information for any
product-specific installation requirements.
- Temperature:
- Operating: -10 to 40 degrees C (14 to 104 degrees F)
- Non-operating: -50 to 100 degress C (-58 to 212 degree F)
- Humidity Operating: 20% to 85%, non-condensing at 40 C (104 F)
- Non-operating: 10% to 85%, non-condensing at 70 C (158 F)
- Operating altitude: Up to 3,000 m (9,800 ft)
- Storage altitude: Up to 12km (32,200)
- Operating Shock: 20G, 6ms half-sine
- Non-operating Shock: 15G, 12-18 ms trapezoid
- Vibration Operating: 0.5 g sine, 0.4 grms random, 5 to 500 Hz
- Non-operating: 2.0 g sine, 1.1 grms random 5 to 500 Hz
- Airflow High speed: 37 CFM
- Low speed (65% speed): 18 CFM cu. ft./min.
- Noise goal: < 53 dB
- AC Input Nominal: 100 to 240 VAC, 2.0 A
- Frequency: 47 to 63 Hz
- Power consumption: 54 Nominal, 66W maximum
- EMC Conformance:
- CFR 47 Subpart B of Part 15 of the FCC Rules, Class A level
- CISPR22 Class A
- EN55022 Class A
- VCCI Class A ITE
- AS/NZS 3548 Class A
- CNS 13438 Class A
- EMC Directive (89/336/EEC) for CE Marking in European Union
- Product Safety/Country Testing/Certification:
- Underwriters Laboratories, UL60950
- Canadian Standards Association, CSA60950
- TUV Rheinland of North America, EN60950
- Nemko, EN60950
- Low Voltage Directive (73/23/EEC) for CE Marking in European Union
Not applicable.
Specific details on supported operating systems, servers, and devices,
storage products attachability, SAN connectivity products, and
configuration options are available at:
- http://www.ibm.com/totalstorage/san/b-type
Rack Requirements
An industry-standard 19-inch rack, or equivalent, with adequate space
available (1 EIA unit for the SAN16B-2 Express Model), and sufficient
power and cooling is required to support the IBM TotalStorage SAN16B-2
Express Model. Included with the switch is a single 240 V power cord for
attachment to the power distribution units of the rack.
To support installability and serviceability in non-IBM industry
standard racks, review the installation planning information for any
product specific installation requirements.
Non-rack-mounted (tabletop) installation is supported. You must order
the required country-specific power cords.
Power Cords
The following list of international power cords have been qualified
for use with the IBM TotalStorage SAN16B-2 switch, and may be purchased
using the appropriate option part number.
Geography Option P/N Description
--------- ---------- ------------------------------------------------
U.S. 94G6667 U.S 125v, 10A, 2.8m - Group 1
Europe 90P4850 European 10A C13 to CEE 7/7 2.8M Power Cord
Denmark 90P4851 Denmark 10A C13 to DK2-5A 2.8M Power Cord Option
Switzerland 90P4852 Switzerland 10A C13 to SEV 1011 2.8M Power Cord
Option
Israel 90P4853 Israel 10A C13 to SI 32 2.8M Power Cord Option
Italy 90P4854 Italy 10A C13 to CEE 7/7 2.8M Power Cord Option
S. Africa 90P4855 South Africa 10A C13 to SABS 164/1 2.8M Power
Cord Option
UK 90P4856 United Kingdom 10A C13 to BS 1363 2.8M Power
Cord Option
Australia/ 90P4857 Australia/NZ 10A C13 to SAA-AS C112 2.8M Power
New Zealand Cord Option
Korea 90P4858 Korea 12A C13 to KETI 15A/250V 2.8M Power Cord
Option
Japan 90P4859 Japan 15A C13 to JIS C-8303 Denan 4.3M Power
Cord Option
India 90P4860 India 10A C13 to IS 6538 2.8M Power Cord Option
China 90P4861 China 10A C13 to GB 2099.1 2.8M Power Cord
Option
Brazil 90P4862 Brazil 10A C13 to NBR 6147 2.8M Power Cord
Option
Argentina 90P4863 Argentina 10A C13 to IRAM 2063 2.8M Power Cord
Option
Specific details on supported operating system releases are available
at:
- http://www.ibm.com/totalstorage/san/b-type
Back to top
Publications
|
The following publications are shipped with the product.
Additional copies of individual publications are available at:
- http://www.ibm.com/totalstorage/san/b-type
Order
Title Number
------------------------------------------ ---------
IBM TotalStorage SANB16-2 Installation, GC26-7753
Service, and User's Guide
IBM eServer Translated Safety Notices G229-9054
IBM TotalStorage SAN b-type 2005 Statement GC26-7754
of Limited Warranty
Back to top
Features -- Specify/Special/Exchange
|
None.
Description Machine Model Part Min Max
--------------------------------- ------- ----- ------ --- ---
IBM TotalStorage SAN16B-2 Express 2005 16B 200516B
16B Express Model 4-Port Upgrade 22R5332 0 2
16B Advanced Security Activation 22R4891 0 1
16B 4-Port Activation 22R4901 0 1
16B Fabric Watch 22R4904 0 1
16B Full Fabric Activation 22R5460 0 1
16B Performance Bundle Activation 22R5469 0 1
Currently available options:
2 Gbps LW SFP Transceiver 19K1272 0 8
4 Gbps SW SFP Transceiver 22R4902 0 8
2 Gbps LW SFP Transceiver 4-Pack 22R0484 0 2
4 Gbps SW SFP Transceiver 4-Pack 22R4897 0 2
IBM 1 M LC-LC Fibre Channel Cable 19K1247 0 16
IBM 5 M LC-LC Fibre Channel Cable 19K1248 0 16
IBM 25 M LC-LC Fibre Channel Cable 19K1249 0 16
IBM SC-LC Fibre Channel Adapter Cable 19K1250 0 16
9 Micron Fibre Cable 31 m, singlemode, SC/LC 22R0487 0 16
9 Micron Fibre Cable 31 m, singlemode, LC/LC 22R0488 0 16
9 Micron Fibre Cable 2 m, singlemode, SC/LC 22R0489 0 16
Additional port upgrade options
The base 200516B Express Model activates the first eight ports (0 to
7), including eight 4 Gbps shortwave SFP Transceivers. You may
optionally purchase activation for ports eight to eleven (first four-port
increment), and ports twelve to fifteen (second four-port increment).
Note: The first port is designated as port zero and the last port is
designated as port fifteen.
(P/N 22R5332) 16B Express Model 4-Port Upgrade with 4 Gbps SW SFPs
This option provides an additional 4-Port Upgrade for the 200516B
Express Model to enable upgrade to 12-, or 16-ports. This upgrade option
includes four 4 Gbps shortwave transceivers.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: Two.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(P/N 22R4901) 16B 4-Port Activation without SFPs
This feature enables additional port activation for ports 8 to 11
(first four port increment) or ports 12 to 15 (second four port
increment) in the 16B switch. Port activation features do not include
fiber optic transceivers.
All activated ports must be populated with additional SFP
transceivers.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: Two.
- Prerequisites: None.
- Corequisites: All available ports must be populated with SFPs.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Advanced functions
(P/N 22R4891) 16B Advanced Security Activation
Advanced Security Activation is designed to enable policy-based
security mechanisms integrated within Fabric Operating System V2.6, V3.1,
and V4.1. To enable advanced security capabilities, all switches within
the IBM SAN Switches Fabric must be configured with their respective
Fabric operating system version (2.6, 3.1, and 4.1) before activating the
Advanced Security feature license key. When activated across the IBM SAN
Switch Fabric, the Advanced Security Activation feature is designed to
support the following security capabilities:
- Centralized security management (trusted switches)
- Fabric-wide security policies to control access
- Port-level access control
- Switch-level access control
- Management access controls (Telnet, SNMP, HTTP, API)
- Encryption of management data such as passwords
- Authentication between switches
Requires Full Fabric Activation for ISL support (P/N 22R5460)
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(P/N 22R4904) 16B Fabric Watch
Fabric Watch enables real-time proactive awareness of the health,
performance and security of each switch, and is designed to automatically
alert network managers to problems in order to help avoid costly
failures::
- Real-time tracking of numerous fabric and switch elements
- Automatic event notifications when switch and fabric elements exceed
thresholds
- Proactive end-to-end health, performance and security monitoring
- Security, availability, and congestion monitoring thresholds and
alerts
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(P/N 22R5460) 16B Full Fabric Activation
Full Fabric Activation is required to enable E_Ports. The switch by
default cannot be connected to another switch until Full Fabric is
installed. Without the license the switch can still be directly
connected to hosts and storage devices.
Full Fabric is a prerequisite to Advanced Security Activation and
Performance Bundle Activation.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(P/N 22R5469) 16B Performance Bundle Activation
Performance Bundle Activation supports both Enhanced ISL Trunking and
Performance Monitoring capabilities.
Performance Monitoring helps identify end to end bandwidth usage by
host/target pairs and is designed to provide information for capacity
planning.
ISL Trunking is designed to enable FC packets to be efficiently
distributed across multiple Inter-Switch connections (links) between two
SAN b-type fabric switches, while preserving in-order delivery. Both SAN
b-type fabric switches must have ISL Trunking activated.
Enhanced ISL Trunking is supported between two SAN16B-2, SAN32B-2, or
SAN256B 4 Gbps models and enables FC packets to be distributed across up
to eight 4 Gbps-capable ISLs for a combined bandwidth of up to 32 Gbps.
When connecting the 4 Gbps capable models to legacy 2 Gbps-capable b-type
fabric switch models, ISL Trunking is supported with link speeds
operational at 2 Gbps and FC packets distributed across up to four ISLs
for a combined bandwidth of up to 8 Gbps.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: One.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Field Installable: No, initial order only.
- Cable Order: None.
Transceivers - Small Form-Factor Pluggable (SFP)
The IBM TotalStorage SAN16B-2 (200516B) switch provides scalability
with ports on demand; 8 ports activated in the base, 12-, and 16-ports
enabled "on demand". Additional port activation is available with part
number 22R4901 and is available with your initial order or for field
installation respectively.
(P/N 19K1272) 2 Gbps LW SFP Transceiver
This feature provides a 2 Gbps longwave SFP transceiver allowing Fibre
Channel connections of up to 10.0 Km (6.2 miles).
(P/N 22R4902) 4 Gbps SW SFP Transceiver
This feature provides a 4 Gbps shortwave SFP fiber optic transceiver,
allowing Fibre Channel connections of up to 150 meters while using the
appropriate 50.0/125 micrometer fiber optic cable, and distances up to 70
meters while using the appropriate 62.5/125 micrometer fiber optic cable.
Customers must verify the installation guide, quality of fiber optic
cable plant, and grade of fiber optic cable relative to applicable
industry standards.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: 8, in 4-ports increments.
- Prerequisites: None.
- Corequisites: Yes. Must have part number 22R4901.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max is total of features of all SFPs.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Transceivers - SFP 4-Pack
(P/N 22R0484) 2 Gbps LW SFP Transceiver - 4-Pack
This feature provides an additional four long wave SFP transceivers,
designed to provide Fibre Channel connections at distances up to 300
meters while using the appropriate 50.0/125 micrometer fiber optic cable,
and distances up to 175 meters while using the appropriate 62.5/125
micrometer fiber optic cable.
(P/N 22R4897) 4 Gbps SW SFP Transceiver - 4-Pack
This feature provides an additional four short wave SFP transceivers,
designed to provide Fibre Channel connections at distances up to 10
Km(6.2 miles), while using the appropriate 9.0/125 micrometer single mode
fiber optic cable.
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: Two.
- Prerequisites: None.
- Corequisites: Yes. Must have part number 22R4901
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Min and Max are totals of all SFP 4-Packs.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
Fiber Optic Cables
A fiber optic cable is required for attaching the IBM TotalStorage
SAN16B-2 switch to host system adapters, or other storage area Fibre
Channel components. The cable can be customer supplied, or ordered with
the 200516B in the lengths available. The connection is an LC connector
type.
(P/N 19K1247) Fiber Cable LC/LC 1m multimode
(P/N 19K1248) Fiber Cable LC/LC 5m multimode
(P/N 19K1249) Fiber Cable LC/LC 25m multimode
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: 16.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of all cables.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
(P/N 19K1250) SC/LC Coupling Cable 1 m
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: 16.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: None.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
9 Micron Fiber Optic Cables
These single mode fiber optic cable features are used to assist
configurations which include longwave SFP transceivers. Customers may
provide their own single mode fiber optic cables, or select among these
single mode fiber optic cable convenience features to connect between
devices.
(P/N 22R0487) 9 Micron Fibre Cable 31m, singlemode SC/LC
(P/N 22R0488) 9 Micron Fibre Cable 31m, singlemode LC/LC
(P/N 22R0489) 9 Micron Fibre Cable 2m, singlemode SC/LC
- Minimum Number of Features per 200516B: None.
- Maximum Number of Features per 200516B: 16.
- Prerequisites: None.
- Corequisites: None.
- Compatibility Conflicts: None.
- Customer Setup: Yes.
- Limitations: Max. is total of all Micron cables.
- Limitations: None.
- Field Installable: Yes, both IPO and MES.
- Cable Order: None.
In many situations, the required lengths and installation of fiber
optic cables will be unique to each customer's configuration and facility
specifications. IBM Network Integration and Deployment Services, offered
by IBM Global Services, can provide assistance for these unique cabling
and installation requirements. For situations where the Fibre Channel
components and attaching subsystems are within the distances available,
there are several features available to accommodate these simple
installations.
Power Cords for non-rack Installation:
You must specify the type of power cord required when ordering the
200516B for non-rack, tabletop use.
Power Cords
The following list of international power cords have been qualified
for use with the IBM TotalStorage SAN16B-2 switch, and may be purchased
using the appropriate option part number.
Geography Option P/N Description
--------- ---------- ------------------------------------------------
U.S. 94G6667 U.S 125v, 10A, 2.8m - Group 1
Europe 90P4850 European 10A C13 to CEE 7/7 2.8M Power Cord
Denmark 90P4851 Denmark 10A C13 to DK2-5A 2.8M Power Cord Option
Switzerland 90P4852 Switzerland 10A C13 to SEV 1011 2.8M Power Cord
Option
Israel 90P4853 Israel 10A C13 to SI 32 2.8M Power Cord Option
Italy 90P4854 Italy 10A C13 to CEE 7/7 2.8M Power Cord Option
S. Africa 90P4855 South Africa 10A C13 to SABS 164/1 2.8M Power
Cord Option
UK 90P4856 United Kingdom 10A C13 to BS 1363 2.8M Power
Cord Option
Australia/ 90P4857 Australia/NZ 10A C13 to SAA-AS C112 2.8M Power
New Zealand Cord Option
Korea 90P4858 Korea 12A C13 to KETI 15A/250V 2.8M Power Cord
Option
Japan 90P4859 Japan 15A C13 to JIS C-8303 Denan 4.3M Power
Cord Option
India 90P4860 India 10A C13 to IS 6538 2.8M Power Cord Option
China 90P4861 China 10A C13 to GB 2099.1 2.8M Power Cord
Option
Brazil 90P4862 Brazil 10A C13 to NBR 6147 2.8M Power Cord
Option
Argentina 90P4863 Argentina 10A C13 to IRAM 2063 2.8M Power Cord
Option
None.
Back to top
Accessories
|
None.
Customer Replacement Parts
None.
Back to top
Machine Elements
|
None.
Back to top
Supplies
|
None.
Diskettes
None.
Trademarks
(R), (TM), * Trademark or registered trademark of International
Business Machines Corporation.
** Company, product, or service name may be a trademark or service
mark of others.
Windows is a trademark of Microsoft Corporation.
© IBM Corporation 2005.
Back to top
|
|
|
|
|
|
|
|